• 제목/요약/키워드: tunnel blasting curing concrete

검색결과 4건 처리시간 0.023초

발파진동의 크기가 양생콘크리트의 강도와 물성에 미치는 영향 (Effects of Blasting Vibrations on Strength and Physical Properties of Curing Concrete)

  • 임한욱;박근순;정동호;이상은
    • 터널과지하공간
    • /
    • 제5권2호
    • /
    • pp.134-143
    • /
    • 1995
  • Effects of blasting vibrations on curing concrete have not been well studied. As a result, unreasonable and strong blasting vibration constraints have been placed on blasting when it occurs in the vicinity of curing concrete. To study the effects of blasting on curing concrete blocks of 33.3X27.7X16.2 cm were molded and placed on the quarry. Several sets of concrete blocks were subjected separately to peak vibrations of 0.25, 0.5. 1.0, 5.0, and 10cm/sec. The impulses of blasting vibrations were applied with thirty-minute intervals. Along with unvibrated concrete blocks, the vibrated concrete samples cored with 60.3 mm in diameter were measured for elastic moduli, sonic velocity and uniaxial compressive strength. Test results can be summarized as follows; 1. The blasting vibrations between 6 and 8 hours after pour generally lowered on the uniaxial compressive strength of the concrete. 2. A low blasting vibration of 0.25 cm/sec did not affect the uniaxial compressive strength. As the magnitude of the blasting vibration increases, compressive strength of concrete is decreased. 3. Physical properties of the P-wave velocity, Young's modulus, and Poisson's ratio showed a weakly decreasing trend in the concrete blocks vibrated between 6 and 8 hours after pour.

  • PDF

인공진동의 크기가 양생콘크리트의 강도와 물성에 미치는 영향 (Effects of Artificial Vibrations on Strength and Physical Properties of Curing Concrete)

  • 임한욱;정동호;이상은
    • 터널과지하공간
    • /
    • 제4권1호
    • /
    • pp.31-37
    • /
    • 1994
  • The effects of blasting and ground vibratons on curing concrete have not been well studied. As a results unrealistic and costly ground vibration constraints have been placed on blasting and piling when it occurs in the vicinity of curing concrete. To study the effects of ground vibrations, a shaking table was made to produce peak particle velocities in the nearly same frequency range as found in construction blasting. Concrete blocks of 33.3X27.7X16.2cm were molded and placed on the shaking table. Different sets of concrete blocks were subjected to peak vibrations of 0.25, 0.5, 1.0, 5.0 and 10cm/sec. The impulses were applied at two hour intervals for thirty seconds. Along with unvibrated concrete blocks, the vibrated concrete samples with 60.3mm in diameters were measured for elastic moduli, sonic velocity, tensile and uniaxial compressive strength. Test results showed that the vibrations in curing concrete generally have effects on the uniaxial compressive strength or physical properties of the concrete.

  • PDF

터널발파-구조물 병행시공을 위한 영향평가 연구 (A Case Study on the Construction of Concrete Structures in Parallel with Tunnel Blasting)

  • 류창하;최병희;김양균;유정훈
    • 화약ㆍ발파
    • /
    • 제21권4호
    • /
    • pp.11-21
    • /
    • 2003
  • 3.6km 장대터널인 미시령터널의 시공기간 단축과 공사비 절감을 위해 터널 발파와 콘크리트 구조물 병행시공 평가 연구를 수행하였다. 이를 위해 기존에 제시된 양생중인 콘크리트 구조물에 대한 진동허용기준을 분석하여 본 현장에 적합한 기준을 제시하였고, 10여회의 발파계측을 통해 약 130점 이상의 계측자료를 획득하여 대상 현장에서의 진동추정식을 도출하였다. 그 결과 발파와 콘크리트 구조물 병행시공을 위한 안전한 작업 지침으로서, 발파시 지발당 최대 장약량에 따라 타설이 가능한 막장으로부터의 안전이격거리가 제시되었다. 이에 대한 실제 검증을 위해 터널내 4곳에 일정한 거리마다 콘크리트 블록을 타설한 후 지속적인 발파 진동을 밭게 한 후 28일 강도시험을 실시하였으며 제시된 지침의 타당성을 확인할 수 있었다.

양생중인 콘크리트에서의 발파진동의 영향 시험방법에 대한 연구 (A Study on Experimental Method of Blasting Vibration in Curing Concrete)

  • 김장득;김용하
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.417-422
    • /
    • 2009
  • 최근 건설되는 터널은 장대화될 뿐만아니라 파쇠대 등의 불량한 지반을 통과하는 사례가 많아지고 있다. 지반 강도가 좋지 않을 때는 터널의 소성변형이 일어나고 때로는 붕락하는 사례도 발생한다. 지금까지의 터널시공방식은 굴착작업이 완료된 후에 라이닝콘크리트를 타설하는 순차적 시공방법이었다. 이 방법은 공사기간이 길고 비용이 많이 들어갈 뿐만 아니라 파쇄대나 소성지반에서 굴착후 장기간 방치했을 때, 터널의 안정을 기대하기 어려운 경우도 있다. 이에 따라 양북터널에서는 터널굴착과 라이닝콘크리트를 동시에 시공하여 공사기간 단축은 물론 심한 파쇄대구간에서 터널을 조기에 안정시키기 위해 동시시공을 계획하게 되었다. 동시시공을 위한 사전 검토사항으로서 발파굴착과 동시에 콘크리트를 타설했을 때 발파진동이 라이닝콘크리트의 강도에 미치지 않는 안전한 이격거리를 산출하기 위한 시험을 현장에서 시행하였다. 또한 동시시공을 위한 라이닝폼의 개선과 콘크리트 타설방법 개선, 집진기를 이용한 환기방식의 개선과 설비의 재배치 등을 동시에 시행하였다.