• 제목/요약/키워드: tunnel airflow

검색결과 66건 처리시간 0.027초

고속으로 회전하는 CD-Rom 드라이브의 공력 소음원 규명 및 소음 저감 (Identifications and Reductions of Aerodynamic Noise Sources in High Speed Rotating CD-Rom Drive)

  • 허대녕;김용석;한승진;김영찬;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.771-776
    • /
    • 2000
  • Major noise source in high speed rotating CD-Rom drives arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. Experimental studies were carried out in the anechoic wind tunnel with various design modifications, such as tray geometry and window size, to identify and reduce the major aerodynamic noise source and significant reductions of the noise source were obtained.

  • PDF

Strouhal number of bridge cables with ice accretion at low flow turbulence

  • Gorski, Piotr;Pospisil, Stanislav;Kuznetsov, Sergej;Tatara, Marcin;Marusic, Ante
    • Wind and Structures
    • /
    • 제22권2호
    • /
    • pp.253-272
    • /
    • 2016
  • The paper concerns with the method and results of wind tunnel investigations of the Strouhal number (St) of a stationary iced cable model of cable-supported bridges with respect to different angles of wind attack. The investigations were conducted in the Climatic Wind Tunnel Laboratory of the Czech Academy of Sciences in $Tel{\check{c}}$. The methodology leading to the experimental icing of the inclined cable model was prepared in a climatic section of the laboratory. The shape of the ice on the cable was registered by a photogrammetry method. A section of an iced cable model with a smaller scale was reproduced with a 3D printing procedure for subsequent aerodynamic investigations. The St values were determined within the range of the Reynolds number (Re) between $2.4{\cdot}10^4$ and $16.5{\cdot}10^4$, based on the dominant vortex shedding frequencies measured in the wake of the model. The model was oriented at three principal angles of wind attack for each of selected Re values. The flow regimes were distinguished for each model configuration. In order to recognize the tunnel blockage effect the St of a circular smooth cylinder was also tested. Good agreement with the reported values in the subcritical Re range of a circular cylinder was obtained. The knowledge of the flow regimes of the airflow around an iced cable and the associated St values could constitute a basis to formulate a mathematical description of the vortex-induced force acting on the iced cable of a cable-supported bridge and could allow predicting the cable response due to the vortex excitation phenomenon.

딥러닝 기반 지하공동구 제어반 문열림 인식 (Deep Learning-based Object Detection of Panels Door Open in Underground Utility Tunnel)

  • 김경환;김지은;정우석
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.665-672
    • /
    • 2023
  • 연구목적: 지하공동구는 도시 지하에 전기, 수도, 가스 등의 인프라를 공동 수용하는 시설로 공기 흐름이 부족하여 계절에 상관없이 결로가 자주 발생한다. 결로는 전기 설비의 누전 화재를 일으키는 원인이 되므로 지하공동구 내의 조명 등 각종 시설물 관리를 위해 필요한 제어반은 결로에 노출되지 않도록 문이 닫힌 상태로 관리되어야 한다. 본 논문에서는 딥러닝 객체인식 기술을 활용하여 수km 거리에 반복 배치된 공동구 제어반의 문 열림 여부를 이동 카메라 조건과 조명이 꺼진 조건에서도 인식하고자 한다. 연구방법: 지하공동구를 순찰하는 로봇이 촬영한 영상데이터를 이용하여 딥러닝 객체인식 모델인 YOLO를 모자이크 이미지 증강기법으로 학습시켜 제어반 문 열림과 문 닫힘을 인식한다. 연구결과: 모자이크 이미지 증강기법으로 학습시킨 모델과 사용하지 않은 모델의 성능을 비교한 결과, 모자이크 학습 모델이 더 우수한 성능(모든 클래스에 대한 mAP가 0.994 이상임)을 보이는 것을 확인하였다. 결론: 지하공동구의 조명이 꺼진 상태에서도, 공동구 내부 시설물이 복잡한 환경에서도 제어반의 문열림 여부를 우수한 성능으로 인식하여 지하공동구 재난안전관리에 도움이 될 것으로 기대된다.

대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구 (Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites)

  • 이창우;웅웬반득
    • 터널과지하공간
    • /
    • 제24권6호
    • /
    • pp.464-472
    • /
    • 2014
  • 환기제어 시설을 설치하지 않고 모든 공간을 개방한 형태의 대단면 주방식 채굴 작업장에 설치하는 국부선풍기의 운전에 따른 기류유동형태는 재순환을 포함하고 있어 복잡하고 정량화가 어렵고 환기효율 또한 매우 낮은 편이다. 본 논문에서는 국부선풍기의 운전에 따라 하류편의 기류 운동에너지 증가 및 정압강하 현상인 벤츄리(venturi) 효과로 인접갱도로부터 기류가 유입되어 기류 유동방향으로 환기량이 증가하는 현상을 선풍기 종류 및 설치방법 별로 CFD분석하였다. 분석대상 선풍기는 축류선풍기 1종류 및 프로펠러 선풍기 2종류이며 축류선풍기 중심점 설치 위치를 1.0, 1.5, 2.0m로 변경함에 따른 벤츄리 효과의 차이를 분석하였다. 연구결과는 공기질 개선을 통한 작업환경 관리를 위한 국부 환기의 경제성 및 효율성을 제고하는데 기여할 것으로 기대된다.

Practical countermeasures for the aerodynamic performance of long-span cable-stayed bridges with open decks

  • Zhou, Rui;Yang, Yongxin;Ge, Yaojun;Mendis, Priyan;Mohotti, Damith
    • Wind and Structures
    • /
    • 제21권2호
    • /
    • pp.223-239
    • /
    • 2015
  • Open decks are a widely used deck configuration in long-span cable-stayed bridges; however, incorporating aerodynamic countermeasures are advisable to achieve better aerodynamic performance than a bluff body deck alone. A sectional model of an open deck cable-stayed bridge with a main span of 400 m was selected to conduct a series of wind tunnel tests. The influences of five practical aerodynamic countermeasures on flutter and vortex-induced vibration (VIV) performance were investigated and are presented in this paper. The results show that an aerodynamic shape selection procedure can be used to evaluate the flutter stability of decks with respect to different terrain types and structural parameters. In addition, the VIV performance of $\prod$-shaped girders for driving comfortableness and safety requirements were evaluated. Among these aerodynamic countermeasures, apron boards and wind fairings can improve the aerodynamic performance to some extent, while horizontal guide plates with 5% of the total deck width show a significant influence on the flutter stability and VIV. A wind fairing with an angle of $55^{\circ}C$ showed the best overall control effect but led to more lock-in regions of VIV. The combination of vertical stabilisers and airflow-depressing boards was found to be superior to other countermeasures and effectively boosted aerodynamic performance; specifically, vertical stabilisers significantly contribute to improving flutter stability and suppressing vertical VIV, while airflow-depressing boards are helpful in reducing torsional VIV.

관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석 (Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis)

  • 유장열;김근호;채명진;김영문;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

도시철도 터널 미세먼지 제거용 하이브리드형 집진장치의 성능평가 (Performance Evaluation of a Hybrid Dust Collector for Removal of Airborne Dust in Urban Railway Tunnels)

  • 우상희;김종범;장홍량;권순박;육세진;배귀남
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.433-439
    • /
    • 2017
  • 도시철도터널은 전동차 운행으로 바닥 먼지가 비산되거나 새로 발생된 마모 먼지로 오염되고 있다. 전동차가 운행하면서 이러한 부유 먼지를 제거하기 위해서 관성집진기인 배플과 전기집진기로 구성된 하이브리드형 집진장치를 개발하였다. 하이브리드형 집진장치의 유량과 집진효율은 서로 반비례하므로, 유량과 집진효율의 관계를 파악하기 위해 2가지 배플 모델을 제작하여 성능을 평가하였다. 유속이 3.4 m/s인 A1 모델을 장착한 집진장치의 $0.5{\mu}m$ 이상인 입자의 집진효율은 30% 이상이었고, 유속이 4.7 m/s인 A2 모델의 경우 20% 이상이었다. 인가전압이 13 kV일 때 1시간 동안 A1 모델 집진장치의 $PM_{10}$ 집진량은 253 mg, A2 모델의 경우 242 mg으로 추정되었다.

공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구 (A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct)

  • 조형제;전규명;민대기;김종원;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.145-160
    • /
    • 2018
  • 초장대 해저터널은 환기를 위한 연직갱 또는 경사갱 설치에 공간적으로 많은 제한을 받게 되므로 일부 인공섬을 건설하여 환기를 수행할 필요가 있다. 그러나 인공섬 설치는 건설의 어려움뿐만 아니라 건설비용이 증가하게 되므로 인공섬 설치를 최소화할 필요가 있다. 이에 따라 환기거리가 증가하여 누풍에 의한 공급 풍량이 커지게 되면, 공사 중 환기를 위한 덕트 설치가 불가능해지거나 팬 정압 및 동력이 상당히 증가하게 된다. 따라서 초장대 해저터널을 건설하기 위해서는 이러한 현실적인 문제를 극복하고 시공 중 터널 내 환경을 쾌적한 상태로 유지할 수 있는 기술력이 필요하다. 선행 연구에서 우리는 누풍이 이 문제들을 해결하는 핵심 인자이며 실험 결과 새로운 접속방식의 누풍율은 대략 $1.46mm^2/m^2$임을 밝혔다(Jo et al., 2017). 본 연구에서는 새로운 접속방식이 적용된 시제품의 누풍율 측정 결과를 제시하고 기존 접속방식의 누풍 성능 개선을 위해 덕트 내부에 연질막 적용시의 누풍 성능 개선을 실험적으로 분석하였다.

지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출특성 (A Study of Heat St Smoke Evacuation Characteristics by the Changing of Operational Method of Tunnel Fan Shaft Ventilation System for Fire on Subway Train Vehicle)

  • 이동호;유지오
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.62-69
    • /
    • 2003
  • 국내의 경우, 지하철 승강장 제연설비는 전용설비로 구축되어 있지 않고 화재발생시 승강장환기설비 및 본선터널부의 환기설비를 제연모드로 절환하여 운영되고 있다. 제연효과는 이러한 까닭으로 환기설비의 위치, 용량 및 급배기방식에 종속된다. 따라서 본 연구는 승강장에 정차한 열차에서 화재가 발생하는 경우를 대상으로 승객의 대피 소요시간을 산출하고 지하철환경해석 프로그램인 SES(Subway Environmental Simulation)를 사용하여 터널부 환기설비의 제연절환운전으로 승강장부에 형성되는 기류의 해석 및 FDS(Fire dynamics Simulator)을 이용하여 화재해석을 제연방식별로 수행한다. 얻어진 가시도 및 승강장 의 온도로부터 본선 터널부 제연모드별 특성을 규명한다.

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.