• 제목/요약/키워드: tuned liquid column damper(TLCD)

검색결과 35건 처리시간 0.03초

실시간 하이브리드 실험법을 이용한 동조액체기둥감쇠기가 설치된 구조물의 지진응답 제어성능 평가 (Performance Evaluation of Controlling Seismic Responses of a Building Structure with a Tuned Liquid Column Damper using the Real-Time Hybrid Testing Method)

  • 정희산;이성경;박은천;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.669-673
    • /
    • 2007
  • In this study, real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped TLCD controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduceits response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is so driven that the error between the interface acceleration computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

  • PDF

레이저진동계를 사용한 동조액체댐퍼의 액체 진동 측정 (Measurement of Liquid Oscillation in Tuned Liquid Dampers using a Laser Doppler Vibrometer)

  • 신윤수;민경원;김준희
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.513-519
    • /
    • 2016
  • 본 논문에서는 기존 파고 측정 센서의 한계를 극복하기 위하여 레이저 장비 중 LDV를 이용하여 동조액체기둥감쇠기 안의 액체의 파고를 측정하는 방법을 제안하고 검증하였다. 비접촉 센서의 장점과 LDV가 속도와 변위를 측정하는 원리를 기술하였고 대상 물체가 액체인 경우에 요구되는 사항들에 대하여 실험적으로 파악하였다. 투명한 액체는 레이저 광선을 대부분 투과시켜 LDV에 되돌아오는 광량이 부족해 측정이 불가능함을 확인하였고 이를 증가시키기 위해 염료를 혼합하였다. 이때, 염료의 색에 따라 광량에 차이가 발생함을 확인하여 LDV에 사용된 레이저 광선의 파장과 연관된 결과를 도출하였다. 염료를 혼합한 후 광량이 충분한 경우에도 발생하는 데이터의 오차를 제거하기 위해 염료의 농도를 변화시키며 그에 따른 데이터의 정확도를 파악하였다. 결과적으로 모든 가시광선의 빛을 반사시키는 흰색의 염료를 충분한 농도로 혼합하였을 때 LDV를 이용한 TLCD의 파고 측정의 실험적인 결과가 용량식 파고계와 일치함을 확인하였다.

Optimum LCVA for suppressing harmonic vibration of damped structures

  • Shum, K.M.;Xu, Y.L.;Leung, H.Y.
    • Smart Structures and Systems
    • /
    • 제20권4호
    • /
    • pp.461-472
    • /
    • 2017
  • Explicit design formulae of liquid column vibration absorber (LCVA) for suppressing harmonic vibration of structures with small inherent structural damping are developed in this study. The developed design formulae are also applicable to the design of a tuned mass damper (TMD) and a tuned liquid column damper (TLCD) for damped structures under harmonic force excitation. The optimum parameters of LCVA for suppressing harmonic vibration of undamped structures are first derived. Numerical searching of the optimum parameters of tuned vibration absorber system for suppressing harmonic vibration of damped structure is conducted. Explicit formulae for these optimum parameters are then obtained by a series of curve fitting techniques. The analytical result shows that the control performance of TLCD for reducing harmonic vibration of undamped structure is always better than that of non-uniform LCVA for same mass and length ratios. As for the effects of structural damping on the optimum parameters, it is found that the optimum tuning ratio decreases and the optimum damping ratio increases as the structural damping is increased. Furthermore, the optimum head loss coefficient is inversely proportional to the amplitude of excitation force and increases as the structural damping is increased. Numerical verification of the developed explicit design expressions is also conducted and the developed expressions are demonstrated to be reasonably accurate for design purposes.

Development of a methodology for damping of tall buildings motion using TLCD devices

  • Diana, Giorgio;Resta, Ferruccio;Sabato, Diego;Tomasini, Gisella
    • Wind and Structures
    • /
    • 제17권6호
    • /
    • pp.629-646
    • /
    • 2013
  • One of the most common solutions adopted to reduce vibrations of skyscrapers due to wind or earthquake action is to add external damping devices to these structures, such as a TMD (Tuned Mass Damper) or TLCD (Tuned Liquid Column Damper). It is well known that a TLCD device introduces on the structure a nonlinear damping force whose effect decreases when the amplitude of its motion increases. The main objective of this paper is to describe a Hardware-in-the-Loop test able to validate the effectiveness of the TLCD by simulating the real behavior of a tower subjected to the combined action of wind and a TLCD, considering also the nonlinear effects associated with the damping device behavior. Within this test procedure a scaled TLCD physical model represents the hardware component while the building dynamics are reproduced using a numerical model based on a modal approach. Thanks to the Politecnico di Milano wind tunnel, wind forces acting on the building were calculated from the pressure distributions measured on a scale model. In addition, in the first part of the paper, a new method for evaluating the dissipating characteristics of a TLCD based on an energy approach is presented. This new methodology allows direct linking of the TLCD to be directly linked to the increased damping acting on the structure, facilitating the preliminary design of these devices.

Vibration control in wind turbines for performance enhancement: A comparative study

  • Rezaee, Milad;Aly, Aly Mousaad
    • Wind and Structures
    • /
    • 제22권1호
    • /
    • pp.107-131
    • /
    • 2016
  • The need for a more affordable, reliable, clean and secure energy has led to explorations in non-traditional sources, particularly renewable energies. Wind is one of the cleanest energy sources that plays a significant role in augmenting sustainability. Wind turbines, as energy convertors, are usually tall and slender structures, and depending on their location (inland or offshore), they can be subject to high wind and/or strong wave loadings. These loads can cause severe vibrations with detrimental effects on energy production, structural lifecycle and initial cost. A dissipativity analysis study was carried out to know whether wind turbine towers require damping enhancement or rigidity modifications for vibration suppression. The results suggest that wind turbines are lightly damped structures and damping enhancement is a potential solution for vibration lessening. Accordingly, the paper investigates different damping enhancement techniques for vibration mitigation. The efficacy of tuned mass damper (TMD), tuned liquid column damper (TLCD), tuned sloshing damper (TSD), and viscous damper (VD) to reduce vibrations is investigated. A comparison among these devices, in terms of robustness and effectiveness, is conducted. The VD can reduce both displacement and acceleration responses of the tower, better than other types of dampers, for the same control effort, followed by TMD, TSD, and finally TLCD. Nevertheless, the use of VDs raises concerns about where they should be located in the structure, and their application may require additional design considerations.

76층 벤치마크 건물에 설치된 다중 동조 액체 기둥 감쇠기의 최적 설계 변수 (Optimal Design Parameters of Multiple Tuned Liquid Column Dampers for a 76-Story Benchmark Building)

  • 김형섭;민경원;김홍진;이상현;안상경
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.251-258
    • /
    • 2004
  • This paper presents the parameter study of multiple tuned liquid damper (MTLCD) applied to the 76-story benchmark building. A parameter study involves the effects of number of TLCD, frequency range, and central tuning frequency ratio, which are important parameters of MTLCD. The performance of MTLCD is carried out numerical analysis which reflects the nonlinear property of liquid motion. The parameters of TLCD exist different each optimal values according to mass ratio. The performance of single-TLCD (STLCD) is sensitive for tuning frequency ratio. Therefore, MTLCD is proposed to protect such the shortcoming of STLCD. The result of numerical analysis presents improved performance for robustness of MTLCD

  • PDF

TLCD와 LCVA의 설계파라미터에 대한 실험적 평가 (Experimental Evaluation of Design Parameters for TLCD and LCVA)

  • 이성경;민경원;박지훈
    • 한국전산구조공학회논문집
    • /
    • 제22권5호
    • /
    • pp.403-410
    • /
    • 2009
  • 본 연구에서는 실험결과를 바탕으로 액체형 기둥감쇠기의 감쇠계수와 제어력에 참여하는 유효질량을 시스템 식별기법을 이용하여 정량적으로 평가하였다. 먼저, 두가지 형태의 동조액체형 기둥감쇠기를 제작하여 진동대 실험을 실시하였다. 다음으로 수조내부 액체의 수위를 변화시켜 가면서 조화하중 가진실험에 의한 감쇠기의 동적특성을 실험적으로 구하였다. 마지막으로 수치해석 모델과 실험결과와의 오차를 최소화하는 것에 의해 수위변화에 따른 감쇠기의 감쇠비와 유효질량을 정량적으로 평가하였다. 시스템 식별결과로부터 감쇠비와 유효질량이 감쇠기의 수위가 증가함에 따라 감소하는 것으로 나타났다.

Experimental study of controllable MR-TLCD applied to the mitigation of structure vibration

  • Cheng, Chih-Wen;Lee, Hsien Hua;Luo, Yuan-Tzuo
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1481-1501
    • /
    • 2015
  • MR-TLCD (Magneto-Rheological Tuned Liquid Column Damper) is a new developed vibration control device, which combines the traditional passive control property with active controllability advantage. Based on traditional TLCD governing equation, this study further considers MR-fluid viscosity in the equation and by transforming the non-linear damping term into an equivalent linear damping, a solution can be obtained. In order to find a countable set of parameters for the design of the MR-TLCD system and also to realize its applicability to structures, a series of experimental test were designed and carried out. The testing programs include the basic material properties of the MR-fluid, the damping ratio of a MR-TLCD and the dynamic responses for a frame structure equipped with the MR-TLCD system subjected to strong ground excitations. In both the analytical and experimental results of this study, it is found that the accurately tuned MR-TLCD system could effectively reduce the dynamic response of a structural system.

TLCD를 이용한 지진하중을 받는 3차원 비정형 건축구조물의 응답제어 (RESPONSE CONTROL OF 3D IRREGULAR BUILDINGS UNDER SEISMIC EXCITATIONS USING TLCD)

  • 김홍진;김형섭;안상경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.66-71
    • /
    • 2003
  • The semi-active TLCD system is investigated for control of responses of 3D irregular buildings under seismic excitations. The TLCD system is a special type of TMD system providing a performance similar to a TMD system but offers a number of practical advantages over the traditional TMD system. The equations of motion for the combined building and TLCD system are derived for multistory building structures with rigid floors and plan and elevation irregularities. Simulation results for control of two multistory moment-resisting space structures with vertical and plan irregularities show clearly that the semi-active TLCD control system reduces the responses of 3D irregular buildings subjected to earthquake ground motions efficiently.

  • PDF

저주파수 하의 TLCD 시스템의 오리피스 형상 효과 (Orifice shape effect of the TLCD system under a low frequency)

  • 임희창
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.30-34
    • /
    • 2014
  • Bluff bodies under the external periodic force vibrate at their own natural or forced frequency. Rectangular bodies or similar structures such as high-rise towers and apartments, and recently a well-cited application - offshore floating bodies, usually needs to reduce these vibrations for stability and the mode control. Therefore, this study is aiming to reduce or control the vibration of a structure by a passive control method, i.e., TLCD (Tuned Liquid Column Damper). Controlling a moving body with a TLCD based on a variety of the orifice shape has been preliminary studied. In order to get a proper control, an optimized study is made on the design of the orifice shape, which has internal plates with the holes. The results show the force acting on the body due to the periodic movement highly depends on the number of holes on the plate and the height of the water level. Therefore, the optimum shape of the orifice and the height of the water level should be confirmed by a series of experiments.