• 제목/요약/키워드: tunable diode laser absorption spectroscopy(TDLAS)

검색결과 15건 처리시간 0.023초

파장가변 다이오드 레이저 흡수 분광학을 사용한 대기환경분석 (Tunable Diode Laser Absorption Spectroscopy for Environmental Monitoring)

  • Ju Sang-U;Kim Seong-Geun
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.247-248
    • /
    • 2003
  • Tunable diode laser absorption spectroscopy (TDLAS) has been widely used in environmental monitoring of gaseous species in the past decade. TDLAS is a direct measurement technique for pollutants such as NOx without any interference from other species. Because of its superior spectral purity (~0.001 ­$cm^{-1}$), absorption linewidths with resolvable rotational structure can be studied in the mid infrared region where strong fundamental vibrational transitions of molecules appear. (omitted)

  • PDF

TDLAS 시스템을 이용한 유해 배기가스의 농도 계측 (The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System)

  • 차학주;김민수;신명철;김세원;전광민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

연소배기 가스의 계측을 위한 다이오드 레이저 센서 (Diode-Laser Absorption Sensors for measurement of combustion Gas)

  • 신명철;김세원;김동혁
    • 한국연소학회지
    • /
    • 제11권3호
    • /
    • pp.26-35
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser, Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. The results showed that gas concentrations of $O_2$, CO, $CO_2$, NO are accurately measured within ${\pm}2%$ error. The application of WMS method increased the beam intensity 2-3 times higher than DA method. It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

파장 변조 기법을 이용한 연소배기 가스의 계측 (Measurement of Exhaust Gas Concentration using Wavelength Modulation Spectroscopy)

  • 김동혁;김세원;신명철;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.97-103
    • /
    • 2006
  • This work forcus on the development of gas sensor that measure the concentrations of exhaust gas using diode laser. Each diode laser for exhaust gas measurement is set to work at near-IR using both DA and WMS methods. Also use of fiber-coupled optical elements makes such a sensor rugged and easy to align. On-line data acquisition and processing can be performed with a PC running LabVIEW software, and absorption signals are measured simultaneously by multiplexing method. Finally, It were experimentally compared WMS (Wavelength Modulation Spectroscopy) with DA (Direct Absorption) for the accuracy.

  • PDF

다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I) (Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I))

  • 안재현;김용모;김세원
    • 한국연소학회지
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

TDLAS에서 temperature binning 방법을 이용한 온도 측정에 대한 실험적 연구 (Experimental study on TDLAS temperature profile measurement using temperature binning method)

  • 윤성운;김세원;신명철;이창엽
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.27-28
    • /
    • 2012
  • Tunable diode laser absorption spectroscopy(TDLAS) measurement techniques for several gases densities and temperatures have been applied in industrial combustion systems. Accurate measurement of temperature profile is very important, especially in power plants and heating furnaces. So profile fitting and temperature binning methods are new issue for accurate measurement of temperature in laser gas sensing. Temperature binning method is applied in this study for the measurement of temperature profile using tube furnace with three temperature zones. In this study the temperature profiles of tube furnace is accurately measured within 5% error, and this technique is proved to be very promising in the field of temperature profile measurement.

  • PDF

가스의 광 흡수 특성 분석을 통한 대형 연소시스템 내 실시간 온도 및 농도 계측에 관한 실증 연구 (An Empirical Study on Real-Time Temperature and Concentration Measurement Through Optical Absorption Characteristic Analysis of Gas in a Large Combustion System)

  • 박지연;소성현;박대근;류창국;이창엽;유미연
    • 한국가스학회지
    • /
    • 제24권5호
    • /
    • pp.29-38
    • /
    • 2020
  • 산업현장의 대형 연소시스템 내부의 온도 및 농도를 실시간으로 정밀하게 계측하는 일은 그 규모 및 환경 조건으로 인해 사실상 어렵다. 현재 주로 사용되고 있는 열전대를 이용한 온도 계측은 점 측정 방식으로 대형 연소시스템 내부 광역 범위의 온도 분석에 적용하기에는 정밀성과 신뢰성이 낮으며, 접근성에 한계가 있다. 농도 분석 측면에서 대부분의 계측 방법은 샘플링 방식으로 실시간 측정이 어렵고 대표성에 한계가 있다. 이러한 한계점을 극복하기 위한 방법으로, 레이저를 이용한 측정법이 지속적으로 개발되고 있다. 레이저 기반 측정법들은 선 평균 측정 방식으로 대표성과 정밀도가 뛰어나 대형 연소시스템 적용에 유리하다. 본 연구에서는 파장 가변형 레이저 흡수 분광법(Tunable Diode Laser Absorption Spectroscopy, TDLAS)을 통해 연소 시에 발생하는 수증기와 산소를 이용하여 실시간으로 온도 및 농도를 측정하였다. 측정 결과 연소시스템 내부 평균 온도는 1330℃, 평균 산소 농도는 3.3 %로 발전소 데이터와 비교하였을 때 유사한 경향성의 측정값을 얻었다.

연소 배관 유동장의 실시간 온도, 농도 측정에 관한 연구 (A Study on the Real-Time Temperature and Concentration Measurement of Combustion Pipe Flow Field)

  • 홍정웅;윤성환;전민규
    • 한국가시화정보학회지
    • /
    • 제20권2호
    • /
    • pp.86-92
    • /
    • 2022
  • Pipe failure due to thermal fatigue and environmental regulations are increasing the importance of pipe monitoring systems in industrial plants. Since most pipe monitoring systems are focus on external crack inspected, it is necessary to temperature and concentration measuring monitoring system inside the pipe. These systems have spatial uncertainty due to sample inspection by one-point measurement. In addition, real-time measurement is not possible due to the limitation of time delay due to contact measurement. In this study, CT-TDLAS (Computed tomography-Tunable diode laser absorption spectroscopy) apply to overcome the limitations of existing methods. Lasers exhibiting an absorption response at a wavelength of 1395 nm were arranged in a lattice pattern on measuring cell. It showed that the inside of the pipe changed to an unstable combustion state over time.

CT-레이저흡수분광법(TDLAS) 성능향상을 위한 레이저 선폭확장 함수 최적 계수 선정에 관한 연구 (Study on Optimal Coefficients of Line Broadening Function for Performance Enhancements of CT-TDLAS)

  • 최두원;조경래;;백태실;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.773-782
    • /
    • 2016
  • The performance of the CT-TDLAS (computed tomography-tunable diode laser absorption spectroscopy) is strongly dependent upon the line broadening functions. The line of the laser beam used in the TDLAS is scattered by the natural broadening, the collisional broadening and the doppler broadening. The influence of the natural broadening to the experimental spectra obtained in the TDLAS is negligible. The influences of the collisional broadening and the doppler broadening to the experimental spectra are relatively large, in high pressure gas flows and in high temperature low pressure gas flows, respectively. In this study, optimal coefficients are proposed for the doppler broadening function by using the experimental data obtained in a flat burner test. The optimal coefficients were ${\gamma}_j=0.16$ and n=0.37. Using these coefficients, the temperature and concentration distributions at the engine exhaust gas pipe have been calculated showing their validities.

다이오드레이저 흡수분광법을 이용한 수증기의 산소 동위원소 성분비 측정 - II (Measurement of Oxygen Isotope Ratio in Water Vapor by using Tunable Diode Laser Absorption Spectroscopy(TDLAS) - II)

  • 정도영;박상언;김재우;고광훈;임권;정의창;김철중
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 제14회 정기총회 및 03년 동계학술발표회
    • /
    • pp.202-203
    • /
    • 2003
  • 여러 가지 원소의 동위원소 성분 분석은 생물학, 화학, 환경학, 연대학, 기후학 연구에 있어서 중요한 정보를 제공하는 유용한 수단이다. 동위원소 성분비를 측정하는 방법으로는 가스 동위원소 질량분석기를 이용한 방법이 사용되어 왔지만, 최근 다이오드 레이저의 발달과 함께 다이오드레이저 흡수분광법(TDLAS)이 개발되어 사용되고 있다. TDLAS 방법의 경우 질량분석기를 이용하는 방법에서는 측정이 불가능한 동일질량 분자의 동위원소 성분비를 측정할 수 있다. (중략)

  • PDF