• 제목/요약/키워드: tubular surface

검색결과 178건 처리시간 0.022초

알루미늄 압출 관재의 표면 결함이 하이드로포밍 성형에 미치는 영향도에 관한 연구 (The effects of the surface defects on the hydroformability of extruded aluminum tubes)

  • 김대현;김봉준;박광수;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2005
  • The need for improved fuel efficiency, weight reduction has motivated the automotive industry to focus on aluminum alloys as a replacement for steel-based alloy. To cope with the needs for high structural rigidity with low weight, it is forecasted that substantial amount of cast components will be replaced by tubular parts which are mainly manufactured by the extruded aluminum tubes. The extrusion process is utilized to produce tubes and hollow sections. Because there is no weld seam, the circumferential mechanical properties may be uniform and advantageous for hydroforming. However the possibility of the occurrence of a surface defect is very high, especially due to the temperature increase from forming at high pressure when it comes out of the bearing and the roughness of the bearing, which cause the surface defects such as the dies line and pick-up. And when forming a extruded aluminum tube, the free surface of the tube becomes rough with increasing plastic strain. This is well known as orange peel phenomena and has a great effect not only on the surface quality of a product but also on the forming limit. In an attempt to increase the forming limit of the tubular specimen, in the present paper, surface asperities generated during the hydroforming process are polished to eliminate the weak positions of the tube which lead to a localized necking. It is shown that the forming limit of the tube can be considerably improved by simple method of polishing the surface roughness during hydroforming. And also the extent of the crack propagation caused by dies lines generated during the extrusion process is evaluated according to the deformed shape of the tube.

  • PDF

ELECTROLYTIC RECOVERY OF PRECIOUS METALS FROM DILUTED SOLUTIONS

  • Roland Kammel;Lieber, Hans-Wilhelm
    • 한국표면공학회지
    • /
    • 제14권4호
    • /
    • pp.209-214
    • /
    • 1981
  • Electrolytic recovery of gold and silver from diluted solutions has at first been applied nearly 100 years ago. Compared with other recovery techniques electrolytic treatment offers several advantages. But to achieve high space-time yields special constructions of electrolytic cells for improved mass transfer are necessary. Ex-tended cathode surface areas and vigorous agitation are important features. Gold and silver recovery by use of newly developed electrolytic cell constructions - rotating tubular bed reactor and impact rod reactor - has been described. Calculations based on industrial application during several years are confirming that electrolytic recovery of precious metalss from diluted solutions has been operated in a very economic way.

  • PDF

표면 개질된 지지체를 이용한 Cu3(BTC)2 튜브형 분리막의 용매열 합성 및 특성분석 (Solvothermal Synthesis and Characterization of Cu3(BTC)2 Tubular Membranes Using Surface Modified Supports)

  • 노승준;김진수
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.214-218
    • /
    • 2014
  • 본 연구에서는 용매열합성법(solvothermal method)을 이용하여 매크로 기공의 알루미나 튜브 지지체 위에 나노기공 $Cu_3(BTC)_2$ 분리막을 제조하였다. In-situ 용매열합성법을 이용하는 경우, 매크로 기공의 알루미나 지지체 위에 균일한 핵생성과 성장을 통해 연속적이고 균열이 없는 $Cu_3(BTC)_2$ 층을 형성하기 어렵다. 본 연구에서는 용매열합성 전에 알루미나 지지체 표면을 $200^{\circ}C$로 가열한 상태에서 Cu 전구체 용액을 분무하여 지지체 표면을 개질한 후, 용매열합성법을 수행하여 연속적이고 균열이 없는 $Cu_3(BTC)_2$ 튜브형 분리막을 제조할 수 있었다. 합성된 $Cu_3(BTC)_2$ 분리막은 XRD, FE-SEM 및 기체투과 실험 등을 통해 분석하였다. $5{\mu}m$의 두께를 가진 $Cu_3(BTC)_2$ 튜브형 분리막을 통한 단일기체 투과실험 결과, $80^{\circ}C$에서 $H_2$가 가지는 투과도는 $7.8{\times}10^{-7}mol/s{\cdot}m^2{\cdot}Pa$이고, $H_2/N_2$, $H_2/CO_2$의 이상선택도는 각각 11.94, 12.82로 계산되었다.

한국산 꿩 난관깔때기의 조직학적 연구 (Histological Studies of the Infundibulum of the Oviduct of the Korean Native Pheasants(Phasianus colchicus korpowi))

  • 최성도;이영훈;김인식;양홍현
    • 한국가금학회지
    • /
    • 제26권3호
    • /
    • pp.171-177
    • /
    • 1999
  • This study was conducted for the histological observation of the infundibulum of the oviduct of the laying Korean native pheasants. The results are as follows : 1. The infundibular wall is composed of the epithelium, lamina propria, muscle layer(inner circular and outer longitudinal muscle), and serosa. The funnel lip is divided into the inner, and outer lip of the epithelium and muscle layer. 2. The epithelium of the funnel lip and most region of the cranial part of the funnel are composed of ciliated columnar cells. In the surface and lateral part of the folds, ciliated cells and non-ciliated secretory cells tend to alternate in the epithelium of the caudal funnel and the necks, but are also found in groups of the simple cuboidal epithelium at the bases of the grooves between the ridges and tubular glands found in the subepithelium. 3. The secretory material of the non-ciliated secretory cills contains PAS-positive and alcian blue-positive granules, and these materials show purple colour in the basic fuchsin-methylene blue stain. 4. The cells of the glandular groove and tubular gland of the neck portion of the oviduct mostly show weak PAS-positive, and alcian blue stain negative reaction. The tubular gland cells of the infndibulum contain pink of purple colour granules, and without reaction in the anterior neck portion of the infundibulum in basic fuchsin and methylene blue stain.

  • PDF

Template Synthesis of Nitrogen-Doped Short Tubular Carbons with Big Inner Diameter and their Application in Electrochemical Sensing

  • Cheng, Rui;Zou, Qiong;Zhang, Xiaohua;Xiao, Chunhui;Sun, Longfei;Chen, Jinhua
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2423-2430
    • /
    • 2014
  • Nitrogen-doped short tubular carbons (N-STCs) with big inner diameter have been successfully synthesized via carbonization of polydopamine (PDA) wrapped halloysite nanotubes (HNTs). The obtained N-STCs have average length of $0.3{\mu}m$ with big inner diameter (50 nm), thin wall (2-3 nm) and large surface area ($776m^2g^{-1}$), and show excellent electrochemical properties. As an example in electrochemical applications, N-STCs were used to electrochemically detect hydrogen peroxide ($H_2O_2$) and glucose. The results showed that the N-STCs modified glassy carbon (N-STCs/GC) electrode had much better analytical performance (lower detection limit and wider linear range) compared to the acid-treated carbon nanotubes (AO-CNTs) based GC electrode. The unique structure endows N-STCs the enhanced electrochemical performance and promising applications in electrochemical sensing.

Monitoring degradation in concrete filled steel tubular sections using guided waves

  • Beena, Kumari;Shruti, Sharma;Sandeep, Sharma;Naveen, Kwatra
    • Smart Structures and Systems
    • /
    • 제19권4호
    • /
    • pp.371-382
    • /
    • 2017
  • Concrete filled steel tubes are extensively applied in engineering structures due to their resistance to high tensile and compressive load and convenience in construction. But one major flaw, their vulnerability to environmental attack, can severely reduce the strength and life of these structures. Degradation due to corrosion of steel confining the concrete is one of the major durability problems faced by civil engineers to maintain these structures. The problem accelerates as inner surface of steel tube is in contact with concrete which serves as electrolyte. If it remains unnoticed, it further accelerates and can be catastrophic. This paper discusses a non-destructive degradation monitoring technique for early detection corrosion in steel tubes in CFST members. Due to corrosion, damage in the form of debonding and pitting occurs in steel sections. Guided ultrasonic waves have been used as a feasible and attractive solution for the detection and monitoring of corrosion damages in CFST sections. Guided waves have been utilized to monitor the effect of notch and debond defects in concrete filled steel tubes simulating pitting and delamination of steel tubes from surrounding concrete caused by corrosion. Pulse transmission has been used to monitor the healthy and simulated damaged specimens. A methodology is developed and successfully applied for the monitoring of concrete filled steel tubular sections undergoing accelerated chloride corrosion. The ultrasonic signals efficiently narrate the state of steel tube undergoing corrosion.

토끼의 발생기 뇨세관과 사구체 세포들의 형태계측학적인 분석 (Morphometrical Analysis of Developing Renal Tubular and Glomerular Cells in Rabbit)

  • 정호중;양영철;배기원
    • 생명과학회지
    • /
    • 제8권4호
    • /
    • pp.449-456
    • /
    • 1998
  • 태생 13일된 토끼의 발생기 신장에서 뇨세관과 사구체 세포들의 크기와 형태를 관찰하여 성숙한 토끼의 신장과 형태계측학적으로 비교한 결과 다음과 같은 결과를 얻었다. 1. 태생 13일의 발생기 뇨세관 단면적은 성숙한 토끼의 근위세관 단면적보다 훨씬 넓고 평균직격이 길었으며 내강이 거의 없었다. 뇨세관 상피세포의 솔모양 가장자리는 발달되지 않았고 핵 위쪽에 둥근 사립체가 발달되었으며 기저막부분에는 사립체가 적었다. 2. 발생기 사구체내에는 벽측세포, 족세포, 내피세포들로 구별되었으며 성숙한 토끼보다 내피세포와 벽측세포의 세포핵 단멱적이 훨씬 컸고 성숙한 토끼의 사구체에서는 족세포가 가장 컸으나 발생기에는 내피세포의 크기가 가장 컸다.

  • PDF

Hysteresis of concrete-filled circular tubular (CFCT) T-joints under axial load

  • Liu, Hongqing;Shao, Yongbo;Lu, Ning;Wang, Qingli
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.739-756
    • /
    • 2015
  • This paper presents investigations on the hysteretic behavior of concrete-filled circular tubular (CFCT) T-joints subjected to axial cyclic loading at brace end. In the experimental study, four specimens are fabricated and tested. The chord members of the tested specimens are filled with concrete along their full length and the braces are hollow section. Failure modes and load-displacement hysteretic curves of all the specimens obtained from experimental tests are given and discussed. Some indicators, in terms of stiffness deterioration, strength deterioration, ductility and energy dissipation, are analyzed to assess the seismic performance of CFCT joints. Test results indicate that the failures are primarily caused by crack cutting through the chord wall, convex deformation on the chord surface near brace/chord intersection and crushing of the core concrete. Hysteretic curves of all the specimens are plump, and no obvious pinching phenomenon is found. The energy dissipation result shows that the inelastic deformation is the main energy dissipation mechanism. It is also found from experimental results that the CFCT joints show clear and steady stiffness deterioration with the increase of displacement after yielding. However, all the specimens do not perform significant strength deterioration before failure. The effect of joint geometric parameters ${\beta}$ and ${\gamma}$ of the four specimens on hysteretic performance is also discussed.

방전드릴의 방전갭과 표면특성에 관한 연구 (A Study on the Relation Between Expansion and the Characteristics of Surface in the ED-Drilling)

  • 최종연;김경환
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.73-79
    • /
    • 2012
  • This paper describes the machining characteristics of the sintered carbide and die steel(STD-11) by electric discharge drilling with various tubular electrodes. Electrical discharge machining(EDM) removes material from the workpiece by a series of electrical sparks that cause localized temperatures high enough to melt or vapourize the vicinity of the charge. In the experiment. four types of electrode which have different diameter are used with the application of continuous direct current and axial electrode feed. The controlled factors include the dimension of the electrode. In drilling by EDM, the dielectric flushed down the interior of the rotating tube electrode, in order to order to facilitate the removal of machining debris the hole. The expansion increase with increasing the thickness of material and the diameter of electrode and the expansion of sintered carbide is 1.75 times large then that of die steel. The taper of machined hole decrease with increasing the thickness of material. The crater sixe of die steel is larger then thet of sintered carbide and the surface roughness of sintered carbide is 1.58 tims larger then that of die steel.

진공관식 태양열 집열 튜브의 열성능 비교 분석 (A Comparative Analysis on the Thermal Performance of Solar Vacuum Collector Tubes)

  • 현준호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.15-22
    • /
    • 2003
  • This study deals with the collection of solar energy and its storage in evacuated tubular collector systems for different types of header design, flow passage and heat transfer devices. In order to elicit the most efficient combination of header design, flow passage, heat transfer hardware and operating conditions, a series of tests were done for the four different types of solar collectors utilizing vacuum tubes. The systems studied here either has the evacuated collector tubes with a metal cap on one end or the all-glass evacuated solar collector tubes These evacuated tubular collectors are known to be more efficient than the flat-plate ones in both direct and diffuse solar radiation. Test results show that the system comprised of the all-glass evacuated tubes with U-shaped copper pipes inside outperforms the other configurations. Especially, a rolled copper sheet tightly placed along the inner surface of each inner tube enhances heat transfer between the heated collector surface and the water contained in the U-shaped copper pipe.