• Title/Summary/Keyword: tubular structure

Search Result 266, Processing Time 0.023 seconds

The influence of the soaking in the manufacturing of positive tubular plates on the performance of lead-acid batteries (튜브식 양극판의 침적공정이 전지 성능에 미치는 영향)

  • Yoon, Youn-Saup;Kim, Byung-Kuan;An, Sang-Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.211-218
    • /
    • 2008
  • The performance of positive plates depends on the structure of the lead dioxide active mass. The positive active materials (PAM) consists of a skeleton, built up of agglomerates and macropores. Agglomerates, in their turn, comprise particles and micropores. This paper described a study conducted to determine the effects of different soaking times between the acid fill and formation stages of the tubular plate production. For the positive plates a lead oxide were filled into tubular bag with a red lead. After filling the positive plates were soaked in $H_2SO_4$ solution. X-ray diffraction(XRD), scanning electron microscopy(SEM) and electrical testing had been used to study the compositional and morphological aspects of the positive active material(PAM) just prior and after formation. Results indicate that PAM compositions were effected by the soaking time and acid density of $H_2SO_4$ solution. It can be seen that as the soaking time duration increases, $\alpha$-PbO, $Pb_3O_4$, and Pb were all gradually sulphating. Composition of 3BS reached a maximum at around 3 h duration and $H_2SO_4$ of sp. gr. 1.10 on soaking. This results would suggest that the most beneficial conditions for soaking were the $H_2SO_4$ of sp. gr. 1.10 and 2 to 6 h of soaking.

Linear Behavior Analysis and Stability Assessment of CFTA Girder (CFTA거더의 선형거동 분석 및 안정성 평가)

  • Jeong, Min-Chul;Yi, Sun-Ae;Kong, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.271-274
    • /
    • 2009
  • 강관의 내부에 콘크리트를 충전한 콘크리트 충전 강관 구조(CFT 구조, Concrete Filled Steel Tubular Structure)는 강재와 콘크리트의 단점을 상호 보완하고, 장점을 극대화 할 수 있다는 이점 때문에 최근 실제 구조물의 시공에 적용하는 사례가 증가하고 있는 추세이다. 이와 같은 CFT 거더의 장점을 살리면서 CFT 거더보다 더 뛰어난 경제적, 구조적 효율성을 얻기 위해 기존의 CFT 구조에 아치 형식과 프리스트레스를 도입한 CFTA(Concrete Filled and Tied Tubular Arch) 거더에 관한 연구가 현재 진행중이다. 본 연구에서는 CFTA 거더의 현장 실험과의 비교를 위해 ABAQUS 6.5-1을 이용하여 CFTA 거더의 유한요소 해석을 수행하였고, 이를 바탕으로 구조물의 선형거동을 분석하였다. 또한 구조물의 위험도 분석을 위해 본 구조물의 가장 약점으로 지적되고 있는 외부로 노출되어 있는 긴장재의 차량 충돌에 의한 사고를 가정하여 이를 고려한 유한 요소 해석을 수행하여 CFTA 구조물의 동적 및 정적 안전성 평가를 수행하고 그 결과를 분석하였다.

  • PDF

Development of a High-power Ultrasonic System for Sonochemistry Reaction (음향화학 반응용 강력초음파 개발)

  • Lee, Yang-Lae;Kim, Hyun-Se;Baek, Min-Hyuck
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.142-148
    • /
    • 2013
  • High-power ultrasonic promotes a chemical reaction by its own energy, thus it has been used for sonochemistry applications. For example, it has been mostly used for mixing, reaction catalyst, dispersion and disintegration. High-power ultrasonic transducer is made with structure based on a Bolt-clamped Langevin type Transducer (BLT), But it has difficulty in the development because degradation of piezoelectric ceramic by the heat generation of BLT. In this study, for a development of the transducer of 25 kHz and 1000 W used in sonochemistry and industrial cleaning, BLT with a hole in its center and tubular type waveguide of the transducer were designed based on finite element method (FEM). The transducer was fabricated based on the design parameter, and the impedance characteristics are measured experimentally and compared with the numerical results.

CFD Analysis of a Counter-rotating Tubular Type Micro-Turbine with Diffuser (디퓨져를 이용한 튜블러형 상반전 수차의 CFD 성능해석)

  • Lee, Nakjoong;Park, Jihoon;Hwang, Young-Ho;Kim, Youtaek;Lee, Youngho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.205.2-205.2
    • /
    • 2011
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this study, in order to acquire design data of counter-rotating tubular type micro-turbine, output power, head, and efficiency characteristics due to the diffuser.

  • PDF

Effects of tendon damage on static and dynamic behavior of CFTA girder

  • Vu, Thuy Dung;Lee, Sang Yoon;Chaudhary, Sandeep;Kim, Dookie
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.567-583
    • /
    • 2013
  • Experimental studies and finite element analyses have been carried out to establish the effect of tendon damage on the structural behavior of concrete filled tubular tied arch girder (CFTA girder). The damage of tendon is considered in different stages by varying the number of damaged cables in the tendon. Static and dynamic structural parameters are observed at each stage. The results obtained from the experiments and numerical studies have been compared to validate the studies. The tendons whose damage can significantly affect the stiffness of the CFTA girder are identified by performing the sensitivity analysis. The locations in the girder which are sensitive to the tendon damage are also identified.

Fatigue Behavior of K-Joint Structure for API 2W Gr.60 Steel (API 2W Gr.60 강재적용 K-Joint 구조의 피로성능평가)

  • Im, Sung-Woo;Chang, In-Hwa;Jo, Chul-Hee;Park, Kwan-Kyu
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.217-222
    • /
    • 2006
  • Large-scale model tests of welded tubular K-joints were carried out to observe the fatigue behavior of API 2W Gr.60 steel produced by POSCO. The fatigue crack behaviors for various loading conditions were measured and investigated around the critical joint sections. The experimental results have been verified with numerical approaches and also compared with the IIW, DnV RP-C203 and API RP 2A-WSD design curves. The hot spot stress method was applied in the study. The SCF factor for tubular K-joint was also obtained.

  • PDF

Experimental Study for Confined Concrete of Double Skinned Composite Tubular Columns by Uniaxial Compression Test (일축 압축 실험을 통한 DSCT 부재의 구속 콘크리트에 대한 실험적 연구)

  • Lee, Jeong-Hwa;Han, Sang-Yun;Won, Deok-Hee;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.13-21
    • /
    • 2013
  • In this study, uniaxial compression tests were performed to investigates the stress-strain relations of Double Skinned Composite Tubular Columns reinforced with steel tube. The confined concrete has been known as the strength of concrete increases significantly. Specimens reinforced with outer and inner steel tube were tested by uniaxial compression test. To investigate the influence of concrete strength increase by confining conditions in steel tubes, 8 specimens with different thickness of tube, hollowness ratio and concrete strength were tested and compared with other researcher's concrete material model.

An Analytic study on the bond of the contact surface in CFT tubular column (중심축하중을 받는 CFT 합성기둥의 접촉면 부착에 관한 해석적 연구)

  • Ye, Sang-Min;Lee, Soo-Young;Kim, Yun-Tae;Park, Seoug-Moo
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.205-212
    • /
    • 2005
  • In order for utilization of the concrete filled tubular, It Is necessary to scrutinize interfacial characteristics between heterogeneous materials, and be performed to various analytical studies on the composite structure. In this paper, this analytic study is carried on using ABAQUS Package/ Version 5.8-1, and the variables aye the relations between the coefficient of friction and the contact pressure for analyzing the behavior on the contact surface, through modifying the analytic methods and improving some problems. It is used to subdivided analytical methods in this research which categorize into four regions and can obtain closer effect for the bond behavior. Four categories compose of the chemical bond and mechanical bond legions replaced the full-interaction before yielding, and the pure friction and moving-down regions after yielding.

  • PDF

The Torque Transmission Capacities of the Adhesive Tubular Lap Joint (접착제로 접착된 원형 겹치기이음의 토크 전달특성 연구)

  • 최진호;이대길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.85-92
    • /
    • 1994
  • With the wide application of fiber-reinforced composite meterial in aircraft space structures and robot arms, the design and manufacture of composite joints have become a very important research area because they are often the weakest areas in composite structure. In this paper, the torque transmission capacities of the adhesive tubular single lap joint and double lap joint were studied. The stress and torque transmission capacity of the adhesive joints were analyzed by the finite element method and compared to the experimental results. The torque capacity of the double lap joint was increased 2.7 times over that of the single lap joint. Also, the fatigue limit of the double lap joint was increased 16 times over that of the single lap joint.

Evolution of concrete encased - CFST column: A comprehensive review on structural behavior and performance characteristics

  • Namitha Raveendran;Vasugi K
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.619-645
    • /
    • 2024
  • In the construction industry, composite structures have revolutionized traditional design principles, opening innovative possibilities. The Concrete Encased - Concrete Filled Steel Tubular (CE-CFST) column stands out as a distinctive composite structure, offering structural stability and resilience for various engineering applications. Comprising Reinforced Concrete (RC) and Concrete Filled Steel Tubular (CFST) components, CE-CFST columns are valued for their inherent properties, including ductility and rigidity, CE-CFST is commonly used in the construction of bridges, high-rise buildings, and more. This article aims to provide a concise overview of the evolutionary development of CE-CFST columns and their performance in structural applications. Through a comprehensive review, the study delves into the behaviour of CE-CFST columns under different scenarios. It examines the influences of key parameters such as size, infills, cross section, failure causes, and design codes on the performance of CE-CFST columns, highlighting their enhanced functionality and future potential. Moreover, the review meticulously examines previous applications of CE-CFST columns, offering insights into their practical implementation.