Browse > Article
http://dx.doi.org/10.12989/scs.2013.15.5.567

Effects of tendon damage on static and dynamic behavior of CFTA girder  

Vu, Thuy Dung (Department of Civil and Environmental Engineering, Kunsan National University)
Lee, Sang Yoon (Structural Engineering & Bridge Research Division, Korea Institute of Construction Technology)
Chaudhary, Sandeep (Department of Civil Engineering, Malaviya National Institute of Technology Jaipur)
Kim, Dookie (Department of Civil and Environmental Engineering, Kunsan National University)
Publication Information
Steel and Composite Structures / v.15, no.5, 2013 , pp. 567-583 More about this Journal
Abstract
Experimental studies and finite element analyses have been carried out to establish the effect of tendon damage on the structural behavior of concrete filled tubular tied arch girder (CFTA girder). The damage of tendon is considered in different stages by varying the number of damaged cables in the tendon. Static and dynamic structural parameters are observed at each stage. The results obtained from the experiments and numerical studies have been compared to validate the studies. The tendons whose damage can significantly affect the stiffness of the CFTA girder are identified by performing the sensitivity analysis. The locations in the girder which are sensitive to the tendon damage are also identified.
Keywords
bridge design; composite structure; concrete filled tubular tied arch; CFTA girder; dynamic behavior; static behaviour;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Chaudhary, S., Pendharkar, U. and Nagpal, A.K. (2009), "Control of creep and shrinkage effects in steel concrete composite bridges with precast decks", J. Bridge Eng., ASCE, 14(5), 336-345.   DOI   ScienceOn
2 Gardner, N.J. and Jacobson, E.R. (1967), "Structural behavior of concrete filled steel tubes", ACI J., 64(7), 404-413.
3 Ge, H.B. and Usami, T. (1992), "Strength of concrete-filled thin-walled steel box columns: Experiment", J. Struct. Eng. ASCE, 118(11), 3036-3054.   DOI
4 Ge, H.B. and Usami, T. (1994), "Strength analysis of concrete-filled thin-walled steel box columns", J. Const. Steel Res., 30(3), 259-281.   DOI   ScienceOn
5 Ge, H.B. and Usami, T. (1996), "Cyclic tests of concrete filled steel box columns", J. Struct. Eng. ASCE, 122(10), 1169-1177.   DOI   ScienceOn
6 Han, L.H. (2000), Concrete Filled Steel Tubular Structures, Peking, Science Press.
7 Han, L.H., Huang, H. and Zhao, X.L. (2009), "Analytical behaviour of concrete-filled double skin steel tubular (CFDST) beam-columns under cyclic loading", Thin-Walled Struct., 47(6-7), 668-680.   DOI   ScienceOn
8 Han, L.H., Huang, H., Tao, Z. and Zhao, X.L. (2006), "Concrete-filled double skin steel tubular (CFDST) beam-columns subjected to cyclic bending", Eng. Structs., 28(12), 1698-1714.   DOI   ScienceOn
9 Knowles, R.B. and Park, R. (1969), "Strength of concrete filled steel tubular columns", J. Struct. Div. ASCE, 95(12), 2565-2587.
10 Korea Institute of Construction Technology (KICT) (2010), A Development of New Type of Girder System Taking Advantage of the Efficiently Composite Structurizing of Structural Construction Materials, Construction & Transportation R&D Report, Ministry of Construction and Transportation.
11 Lee, S.J. (2007), "Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads", Steel Compos. Struct., Int. J., 7(2), 135-160.   DOI   ScienceOn
12 Morcous, G., Hanna, K., Deng, Y. and Maher, T.K. (2010), "Concrete-filled steel tubular tied arch bridge system: Application to Columbus viaduct", J. Bridge Eng. ASCE, 17(1)107-116.
13 Trinh, T.T., Kim, J.H., Park, K.H. and Kong, J.S. (2008), "Dynamic behavior and reliability assessment of a CFTA girder subjected to truck collision", Int. J. Steel Struct., 8(4), 315-324.
14 Sakino, K., Nakahara, H., Morino, S. and Nishiyama, I. (2004), "Behavior of centrally loaded concrete-filled steel-tube short columns", J. Struct. Eng. ASCE, 130(2), 180-188.   DOI   ScienceOn
15 Shams, M. and Saadeghvaziri, M.A. (1999), "Nonlinear response of concrete-filled steel tubular columns under axial loading", ACI J., 96(6), 1009-1017.
16 Susantha, K.A.S., Ge, H.B. and Usami, T. (2001), "Uniaxial stress-strain relationship of concrete confined by various shaped steel tubes", Eng. Struct., 23(10), 1331-1347.   DOI   ScienceOn
17 Xiao, Y., He, W. and Choi, K.K. (2005), "Confined concrete-filled tubular columns", J. Struct. Eng. ASCE, 131(3), 488-497.   DOI   ScienceOn
18 Xiao, Y., He, W. and Choi, K.K. (2010), "Analytical model of circular CFRP confined concrete-filled steel tubular columns under axial compression", J. Comp. Construct., 14(1), 125-133.   DOI   ScienceOn
19 Yang, Y.F., Han, L.H. and Zhu, L.T. (2009), "Experimental performance of recycled aggregate concrete-filled circular steel tubular columns subjected to cyclic flexural loadings", Adv. Struct. Eng., 12(2), 183-194.   DOI   ScienceOn