• 제목/요약/키워드: tubular section joints

검색결과 25건 처리시간 0.028초

X형 관이음부의 보강방법에 따른 극한강도 해석 (Effect of Reinforcement Type on Ultimate Strength of Tubular X-Joints)

  • 조현만;류현선;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.230-237
    • /
    • 2000
  • Tubular joints of jacket structures are usually reinforced using thicker can section, internally ring stiffeners, diaphragm, or externally gusset plates to increase load carry capacity. In this paper, the effect of reinforcement type and geometric parameters of stiffener on the ultimate strength of tubular X-joints subjected to brace compression have been studied numerically Three reinforcement methods were considered; (1)can reinforcement (2)internally ring stiffener (3)internally longitudinal diaphragm. The ANSYS software was used nonlinear strength analysis. It was found that there is significant strength enhancement for reinforced joints.

  • PDF

Modelling and classification of tubular joint rigidity and its effect on the global response of CHS lattice girders

  • Wang, Wei;Chen, Yiyi
    • Structural Engineering and Mechanics
    • /
    • 제21권6호
    • /
    • pp.677-698
    • /
    • 2005
  • In engineering practice, tubular connections are usually assumed pinned or rigid. Recent research showed that tubular joints may exhibit non-rigid behavior under axial or bending loads. This paper is concerned with establishing a new classification for tubular joints and investigating the effect of joint rigidity on the global behavior of CHS (Circular Hollow Section) lattice girders. Parametric formulae for predicting tubular joint rigidities are proposed, which are based on the finite element analyses through systematic variation of the main geometric parameters. Comparison with test results proves the reliability of these formulae. By considering the deformation patterns of respective parts of Vierendeel lattice girders, the boundary between rigid and semirigid tubular connections is built in terms of joint bending rigidity. In order to include characteristics of joint rigidity in the global structural analysis, a type of semirigid element which can effectively reflect the interaction of two braces in K joints is introduced and validated. The numerical example of a Warren lattice girder with different joint models shows the great effect of tubular joint rigidities on the internal forces, deformation and secondary stresses.

Hysteretic behaviour of circular tubular T-joints with local chord reinforcement

  • Shao, Y.B.;Wang, Y.M.;Yang, D.P.
    • Steel and Composite Structures
    • /
    • 제21권5호
    • /
    • pp.1017-1029
    • /
    • 2016
  • When a welded circular hollow section (CHS) tubular joint is subjected to brace axial loading, failure position is located usually at the weld toe on the chord surface due to the weak flexural stiffness of the thin-walled chord. The failure mode is local yielding or buckling in most cases for a tubular joint subjected to axial load at the brace end. Especially when a cyclic axial load is applied, fracture failure at the weld toe may occur because both high stress concentration and welding residual stress along the brace/chord intersection cause the material in this region to become brittle. To improve the ductility as well as to increase the static strength, a tubular joint can be reinforced by increasing the chord thickness locally near the brace/chord intersection. Both experimental investigation and finite element analysis have been carried out to study the hysteretic behaviour of the reinforced tubular joint. In the experimental study, the hysteretic performance of two full-scale circular tubular T-joints subjected to cyclic load in the axial direction of the brace was investigated. The two specimens include a reinforced specimen by increasing the wall thickness of the chord locally at the brace/chord intersection and a corresponding un-reinforced specimen. The hysteretic loops are obtained from the measured load-displacement curves. Based on the hysteretic curves, it is found that the reinforced specimen is more ductile than the un-reinforced one because no fracture failure is observed after experiencing similar loading cycles. The area enclosed by the hysteretic curves of the reinforced specimen is much bigger, which shows that more energy can be dissipated by the reinforced specimen to indicate the advantage of the reinforcing method in resisting seismic action. Additionally, finite element analysis is carried out to study the effect of the thickness and the length of the reinforced chord segment on the hysteretic behaviour of CHS tubular T-joints. The optimized reinforcing method is recommended for design purposes.

고리형 내부 보강재를 가진 X형 관이음부의 축방향 강도 평가 (Axial Strength Evaluation for Tubular X-Joints with Internal Ring Stiffener)

  • 조현만;류연선;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.162-169
    • /
    • 2001
  • Tubular joints are usually reinforced using thicker can section or ring stiffeners to increase the load carrying capacity. In this paper, a numerical study has been performed for evaluation of axial strength for X-joints with internal ring stiffener, The finite element analysis software was used for nonlinear strength analysis. According to variation of ring geometries, the effect of ring stiffener for X-joints are investigated. Internal ring stiffener is found to be efficient improving ultimate strength of tubular joints. Relations of thickness of ring and axial strength are observed considering geometric parameters of ring stiffeners.

  • PDF

Fatigue Strength and Fracture Behaviour of CHS-to-RHS T-Joints Subjected to Out-of-Plane Bending

  • Bian, Li-Chun;Lim, Jae-Kyoo;Kim, Yon-Jig
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.207-214
    • /
    • 2003
  • The fatigue behaviour of six different hollow section T-joints subjected to out-of-plane bending moment was investigated experimentally using scaled steel models. The joints had circular brace members and rectangular chord members. Hot spot stresses and the stress concentration factors. (SCFs) were determined experimentally. Fatigue testing was carried out under constant amplitude loading in air. The test results have been statistically evaluated, and show that the experimental SCF values for circular-to-rectangular (CHS-to-RHS) hollow section joints were found to be below those of circular-to-circular (CHS-to-CHS) hollow section joints. The fatigue strength, referred to experimental hot spot stress, was in reasonably good agreement with referred fatigue design codes for tubular joints.

축하중을 받는 콘크리트 충전 원형 강관 N형 이음부의 핫스폿 응력 특성 (Hot Spot Stress of Concrete-filled Circular Hollow Section N-joints Subjected to Axial Loads)

  • 김인규;정철헌;김영진
    • 대한토목학회논문집
    • /
    • 제30권2A호
    • /
    • pp.113-120
    • /
    • 2010
  • 콘크리트 충전강관을 이용한 교량은 새로운 형식의 교량 형태이다. 강관을 이용한 교량을 적용하는데 있어서 가장 중요한 것은 이음부의 설계이다. 이 논문에서는 축하중을 받는 충전강관 N형 이음부에서 현재는 충전강관으로 브레이스는 강관으로 구성된 이음부의 특성을 범용 프로그램인 ABAQUS를 이용하여 유한요소해석을 통해 고찰하였다. 충전강관 이음부의 핫스폿 응력을 결정하는 기하학적 인자 중, 용접 각장길이, 현재의 직경, 브레이스의 두께에 따른 핫스폿 응력의 차이점을 비교하였다. 또한 충전강관 N형 이음부에서 사재의 각도와 수직재와 사재사이의 거리를 변수로 하여 유한요소해석을 수행하였으며, 현재에 충전된 콘크리트의 강도의 변화에 따른 이음부의 핫스폿 응력 특성을 살펴보았다.

Fatigue Fracture Behaviour of Hollow Section Joints

  • Lichun Bian;Lim, Jae-Kyoo
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2001년도 추계학술발표대회 개요집
    • /
    • pp.281-284
    • /
    • 2001
  • Fatigue behaviour of eight different hollow section T-joints was investigated experimentally using scaled steel models. The joints had circular brace members and rectangular chords (CRHS). Hot spot stresses and the stress concentration factors (SCFs) were determined experimentally. Fatigue testing was carried out under constant amplitude loading in air. The experimental SCF values for CRHS joints were found to be between those of circular-to-circular (CCHS) and rectangular-to-rectangular (RRHS) hollow section joints. The fatigue strength referred to experimental hot spot stress was in reasonably good agreement with current fatigue design codes for tubular joints.

  • PDF

원형강관 플랜지 이음에 관한 실험적 연구 (Experimental Study on Circular Flange Joints in Tubular Structures)

  • 신창훈;한덕전
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.119-127
    • /
    • 2002
  • 본 연구의 목적은 강관구조물에서 고력볼트로 인장접합되는 플랜지 이음의 거동을 연구하는데 목적이 있다. 9개의 플랜지 이음 실험체의 실험을 수행하였으며, 실험시 고력볼트의 변형율과 이음부의 변형율 그리고 변위를 측정하였다. 고력볼트의 변형율, 플랜지 사이에서 발생하는 지레반력 그리고 강관과 플랜지 판의 응력분포를 연구하였다. 원형강관 플랜지 이음 설계에 사용되는 기준식을 비교 분석하였다.

압축과 휨을 동시에 받는 강관 T조인트 극한강도 상호작용 (Ultimate Strength Interaction of Steel Tubular T-Joint Subjected to Concurrent Action of Compression and Bending)

  • 김경식
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.298-303
    • /
    • 2016
  • 수직 및 수평의 원형단면 강관으로 구성된 공간프레임 타워는 강재량을 줄이면서도 풍하중의 영향을 완화시킬 수 있는 장점으로 다양한 목적으로 널리 적용되고 있다. 이러한 공간프레임 타워를 하나의 타워구조로 거동하게 하기 위해서는 수직 강관과 수평 강관의 연결부인 강관조인트의 강도 확보가 중요하다. 본 연구에서는 압축과 휨이 동시에 작용하는 강관 T조인트의 강도평가를 수행하였다. AISC, Eurocode3, ISO 19902의 3가지 강관조인트 설계기준을 검토하고, 주강관과 지강관의 세장비를 주요 매개변수로 한 비선형 유한요소해석을 통하여 축력과 모멘트에 대한 극한강도 상호작용을 설계식으로 제안하였다.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.