• Title/Summary/Keyword: tubular membrane

Search Result 189, Processing Time 0.017 seconds

Biodiesel Production using Microfiltration Tubular Membrane (정밀여과용 관형막을 이용한 바이오디젤 제조)

  • Lee, Won-Joong;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • Biodiesel was produced from Canola, soybean and Jatropha oils combined methanol using continuously recycled membrane reactor. The membrane served to react and separate the unreacted oil from the product stream, producing high-purity fatty acid methyl ester (FAME). Two ceramic tubular membranes having different nominal pore sizes of 0.2 and 0.5 ${\mu}m$ were used. Permeate was observed at 0.5, 1.0 and 2.0 bar with a given flow rate, respectively. The permeate flux for 0.2 ${\mu}m$ membrane at 0.5 bar and 400 mL/min flow rate was 15 L/$m^2{\cdot}hr$. Also FAME content in permeate was the highest at 0.5 bar, and decreased with increasing operating pressure.

A Study on Characteristic Factors of Tubular Membranes in a Membrane coupled Activated Sludge Process (Tubular형 막을 이용한 활성슬러지법에 있어서 여과특성에 미치는 인자에 관한 연구)

  • Park, Sung-Won;Kim, Hyung-Soo;Cho, Dae-Chul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.113-124
    • /
    • 1999
  • We elucidated factors such as membrane pore size, activity of the activated sludge and MLSS. affecting filtering characteristics or filtering resistance in an activated sludge bio-process using tubular type membranes. We used a commercial membrane module with $0.5m^2$ of effective membrane area and a bundle of 7 tubes(13mm of ID and 2m long) in the experiments. As a result, the flux was maintained in the range of $35{\sim}105l/m^2$ hr at 5,000~20,000mg/l of MLSS concentration, and there seemed to be a correlation between the flux and the MLSS. Also the greater the pores were, the higher the flux was in some comparison experiments using UF and MF membranes, but the water permeated through both of the membranes showed almost the same quality. However, the MF membrane showed a great reduction in filtering resistance initially, but went back to a stable stage afterwards. The activity of the activated sludge in the aeration tank was also found to be considered as a factor showing permeation characteristics of the membrane.

  • PDF

Oxygen Permeation Properties of Tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) Membranes under Different Condition of Feed Side and Permeate Side (공급 측과 투과 측 조건에 따른 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) 관형 분리막의 산소투과 특성)

  • Kim, Jong-Pyo;Park, Jung-Hoon;Lee, Yong-Taek;Choi, Young-Jong
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.155-162
    • /
    • 2011
  • Dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ (BSCF) membranes were prepared by extrusion technique. The phase structure of the $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membranes was characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). Relative density of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ tubular membrane was 94.10%. Oxygen permeation was measured at difference operating condition of feed side and permeate side in the temperature range from 700 to $950^{\circ}C$. The oxygen permeation flux of dense tubular $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane reached maximum 1.37 mL/$min{\cdot}cm^2$ at $900^{\circ}C$ exposed to ambient air (feed side) and vacuum pump (permeate side).

Application of tubular membrane to thickening process as a pre-treatment of anaerobic digester (관형막을 이용한 혐기소화조의 전처리 농축공정으로써 적용가능성 연구)

  • Kang, Hee-Seok;Park, Ki-Tae;Park, Jung-Woo;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The purpose of this study is to estimate the applicability of a stable anaerobic digester using a separator membrane to the preprocessing thickening process. The results of the experiments showed about a 47.16% weight loss rate for the sludge under anaerobic condition, and about 41.17% under intermittent aeration condition. The concentrations of rejection water were $SCOD_{Cr}$ 25 mg/L, T-N 16.6 mg/L, and T-P 1.4 mg/L on the average under the intermittent aeration condition, which were lower than the concentrations of rejection water under an anaerobic condition. As for the factors affecting the reduction of the flux, correlation analyses of TTF, MLSS, $SCOD_{Cr}$, and $EPS_{Protein}$, $EPS_{Polysacchride}$ resulted in -0.97, -0.95, -0.84 and -0.86, -0.95, respectively, which showed that TTF had the highest correlation to the reduction of the flux. In addition, it was concluded that MLSS, $SCOD_{Cr}$ and $EPS_{Protein}$, $EPS_{Polysacchride}$ also have close correlations. The results are considered to show that, in the case of the process using a tubular membrane in the preprocessing process of an anaerobic digester, an intermittent aeration condition of the thickener considering the contamination of the membrane and load of rejection water is appropriate for the stable preprocessing process.

Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor (활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가)

  • Seo, Gyu-Tae;Lee, Teak-Soon;Park, Young-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.234-238
    • /
    • 2008
  • Coarse pore filter could be an alternative of membrane for solid-liquid separation in an activated sludge reactor because of inexpensive cost of the filter material and high flux at low filtration pressure. However such filter module has much less specific filtration area compared to the membrane. Therefore a certain effort is required to increase the specific filtration area in the module design of such coarse pore filter for solid-liquid separation in an activated sludge reactor. In this study, tubular type coarse pore filter was designed at various diameter and configuration. The filtration performance was investigated to separate solid in the activated sludge reactor for domestic wastewater treatment. Tubular type coarse pore filter module could be successfully applicable to solid separation in the activated sludge reactor. The design parameters were the tube diameter of 10mm and vertical installation. Smaller diameter of the tube caused faster increase of the filtration pressure because of the hydraulic head loss in the tube channel.

Ammonia Removal Characteristics in Membrane Contactor System Using Tubular PTFE Membrane (관형 PTFE 분리막을 이용한 막 접촉기(Membrane Contactor) 시스템에서 암모니아의 제거 특성)

  • Ahn, Yong-Tae;Hwang, Yu-Hoon;Shin, Hang-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.353-358
    • /
    • 2011
  • In this study, ammonia removal characteristics in membrane contactor system under various operating conditions were evaluated. The mass transfer coefficient was used to quantitatively compare the effect of various operation conditions on ammonia removal efficiency. Effective removal of ammonia was possible with the tubular PTFE membrane contactor system at all tested conditions. Among the various operation parameters, contact time and solution pH showed significant effect on ammonia removal mechanism. Overall ammonia removal rate was not significantly affected by influent suspended solution concentration unlike other pressure driven membrane filtration processes. Also the osmotic distillation phenomena which deteriorate the mass transfer efficiency can be minimized by preheating of strip solution. Membrane contactor system can be a possible alternative to treat high strength nitrogen wastewater by optimizing operation conditions such as stripping solution flow rate, influent wastewater temperature, and influent pH.

Permeation Characteristics of the Microfiltration Tubular Module using the Discharged Rod (배출봉을 이용한 정밀여과용 관형 모듈의 투과특성)

  • Chung, Kun-Yong;Choi, Jeong-Gyu
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2009
  • The permeation experiments were carried out for the nominal pore size $0.1\;{\mu}m$ and 5 mm inner diameter microfiltration tubular membrane equipped with self-designed discharging rod in order to determine the effect of fouling reduction. Dioctyl tinoxide (DOTO) latex particle was used to prepare up to 0.5 wt% concentration of feed solution, and the experiments were operated within 1.6 bar. The permeation flux effect on the discharged rod was measured as a result of flux comparison between the cases of equipped and non-equipped discharge rod modules for every experiment. The permeation flux for the case using the discharged rod was enhanced to 20% at 1.6 bar operating pressure. The improvement on permeation flux for using the discharged rod was greater as the concentration of feed increased, and reached up to 43% under 0.5 wt% concentration of feed solution.

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (I). Continuous-Automated Determination of Nitrite Ion Using Tubular PVC Membrane Type of pH Electrode (용해기체 분석용 기체 감응막 이온선택성 전극 (제 1 보). 관형 PVC 막 pH 전극을 이용한 아질산이온의 연속·자동화 정량)

  • Heung Lark Lee;Jong Hoon Yun
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.4
    • /
    • pp.388-398
    • /
    • 1989
  • A continuous-automated method for the determination of nitrite ion using gas-sensing membrane electrode was developed. The pH electrode of tubular PVC membrane type was used as a detector of this system. The slope of linear response of the electrode measured at optimum conditions for the continuous-automated determination of nitrite ion was 63.5 mV/decade. The concentration range of linear response and detection limit were 2.5 ${\times}10^{-4}{\sim}\;7.5{\times}10^{-2}$M and $8.0{\times}10^{-5}$M, respectively. This detection system was not only less interfering to acidic gas species than other methods but also less time consumable for determination.

  • PDF

Experimental and Theoretical Consideration for Flow Rate, Pressure Drop, and Permeate Flow in a Hollow Fiber Membrane (중공사 막을 따라 흐르는 순수한 물의 유량, 압력손실, 투과수에 대한 실험과 이론적 고찰)

  • Lee, Jung-Muk;Lee, Bomsock
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.470-480
    • /
    • 2012
  • In this study, for a linear tubular membrane with constant diameter the mass balance considering permeate velocity of the each unit length was established. On this basis, mathematical modelling of flows in a pipe was solved using nonlinear second order differential equations as well as steady-state equation. Since this equation is nonlinear, Gauss-Seidel method or another iteration method were used to solve the differential equations. Simulation algorithm for numerical solutions was presented. Also since the permeate flow is varied as operating condition, the solution of equations at each conditions using numerical integrations such as Simpson's rules was used. In order to analyze and compare simulation results, we have performed experiments using a hollow fiber membrane with almost identical tubular membrane. Comparison of theoretical and experimental results, pressure drop, flow rate, and permeate flow in a hollow fiber membrane, were illustrated.

Membrane Perfomance of Sulfonated Polyetherimide

  • 김완주;권영남;전종영;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.71-72
    • /
    • 1996
  • Polyetherimide(PEI)계의 고분자는 막 성능이 우수하고 내열성과 내유기용매성 등이 우수한 열가소성수지로서 film, sheet, tubular형으로 만들 수 있어 한외여과막이나 역삼투막, 기체분리막 등에 이용되고 있다. 한편 투과속도를 높이고, fouling을 줄이기 위한 친수성 향상은 막 소재의 화학적 개질에 있어서 주된 목표이다. sulfonation은 막 재질의 소수성을 감소시켜 water permeability를 향상시키는데 있어서 매우 유용한 방법으로 이온교환수지, 이온교환막, anion형 하전막의 제조에 이용되어 왔다. 본 실험에서는 polyetherimide계 고분자를 chlorosulfonic acid(CSA)를 이용하여 술폰화시킨 sulfonated polyetherimide(SPEI)를 제조하여 막 성능을 측정하였다.

  • PDF