• Title/Summary/Keyword: tubing

Search Result 248, Processing Time 0.026 seconds

Clinical Cases Analysis of Forearm Free Fasciocutaneous Flaps on Oral Cavity Defect Area (구강 결손부에 적용된 요골 유리전완 피부피판 적용례 분석)

  • Kim, Uk-Kyu;Lee, Kwang-Ho;Song, Won-Wook;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.324-331
    • /
    • 2010
  • The radial forearm free flap (RFFF) has become a workhorse flap as a means of reconstructing surgical defects in the head and neck region. We have transferred 12 RFFFs with fasciocutaneous type on oral cavity defects in 12 patients after cancer resection and submucous fibrotic lesion ablation from 2005 to 2007 at Department of oral and maxillofacial surgery, Pusan National University Hospital. We reviewed retrospectively patients' charts and followed up the patients. Clinical analysis on the cases with RFFFs focusing on flap morbidity, indications and available vessels was done. The results of study are follows: 1. RFFF could be applied for all kind of defects after resection of tongue, floor of mouth, buccal mucosa, denuded bone of palate, maxilla, and mandible. 2. All free flaps could be used for primary reconstruction. The survival rate of 12 RFFFs was 92%. Partial marginal loss of the flaps was shown as 3 cases among 12 cases. Large size-vessels like superior thyroid artery, facial artery, internal jugular vein were favorable for microvascular anastomosis. 3. Parenteral nutrition instead of nasal L-tube also can be favorable for postoperative a week for better healing of the flap if the patients couldn't be tolerable with nasal tubing. 4. Donor sites with thigh skin graft were repaired with wrist band for 2 weeks. The complications included scarring, abnormal sensation on hand, and reduced grip strength in few patients, but those didn't induce major side effects. 5. Most RFFFs were well healed even if mortality rate of cancer patients was shown as 50% (5/10 persons). The mortality of patients was not correlated with morbidity of the flaps. We could identify the usefulness of RFFF for restoration of oral function, esthetics if the flap design, tissue transfer indications, and well controlled operation are proceeded.

A Study on the Nurse's Recognition and Performance in Intravenous Therapy Management (간호사의 정맥주사 관리에 대한 인식과 수행에 관한 연구)

  • Kim Myung-Hee;Kim Youn-Hwa
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.207-224
    • /
    • 1998
  • The purposes of this study were to identify nurse's recognition and performance and to represent the factors of hindrance in the IV therapy management. The subjects were 420 nurses who worked at five general hospitals in Pusan. Tha data were collected using a questionnaire and the period of data collection was from January 1 to January 31, 1998. The instrument for this study was made by author oneself on the basis of guidelines Simmons et al', CDC' Stanley' and Kurdi' guideline, Cllinical Nurse's Association' that consist of 68 items for 5 fields ; pre-injection, just before-injection, needle-injection, during injection, post-injection field. Cron-bach Alpha coefficient of recognition and performance in the IV therapy management was .93 and .87. The datas were analized by a SPSS program using frequency, percent, paired t-test, t-test and oneway ANOVA. The results obtained were as follows : 1. The mean score of recognition in IV therapy management was significantly higher than that of performance(t=5.86, P<.001). 2. The items of lower than mean score of each fields in performance were the identification of drugs, hands washing, patient teaching about medication, disinfectional methods of the injection site and the rubber stopper in bottle, the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, use of tape and armboard, changing the IV tubing, labeling the dressing over the injection site, observation and recordings of patient's condition after medication and confirmation of the needle length at the needle removal. 3. The factors of hindrance in IV therapy were 'having no time', 'insufficiency of goods', 'unknowing of methods', 'no disadvantage', and 'factors of doctor's doing'. The most important factor was 'have no time', especially item of hands washing. The other factors of hindrance showed high frequency in the following items ; 'insufficiency of goods' in the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, 'unknowing of methods' in the certification of drugs compatibility, 'no disadvantage' in the labeling the dressing over the injection site, and 'factors of doctor's doing' in the changing the subclavian catheter dressing and checking the glucose level during the TPN infusion. In conclusion, there is necessity of educational program which can improve the nurse's knowledge of drugs, disinfection methods, comfort of patient and recordings in IV therapy management and alternative plan which are political and financial aids such as setting up the sink, giving of paper towels and necessary goods in the IV therapy for reducing the factors of hindrance for IV therapy management.

  • PDF

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Measurement of Formaldehyde in the Atmosphere using a Dual-channel Glass Coil Sampler (이중 채널 유리코일 샘플러를 이용한 대기 중 포름알데하이드 측정)

  • Park Seung-Shik;Hong Sang-Bum;Lee Jai-Hoon;Cho Sung-Yong;Kim Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.259-266
    • /
    • 2006
  • A dual-channel glass coil sampling technique was used to measure hourly formaldehyde concentration in the ambient air. The dual-channel coil sampling assembly consists of three parts; an all-pyrex 28-turn coil made of 0.2-cm internal diameter glass tubing for gas-liquid contact and scrubbing of soluble gases, an inlet section upstream of the coil for introducing sample air and scrubbing solution, and a widened glass section downstream of the coil for gas-liquid separation. The scrubbing solution used was a dilute aqueous DNPH (dinitrophenylhydrazine) solution. Hourly concentration of formaldehyde was determined at a Gwangju semi-urban site during two intensive studies between September and October using the dual channel glass-coil/DNPH sampling technique and HPLC (High Performance Liquid Chromatography) analysis. The mean concentration was 1.7($0.4{\sim}4.7$) and 3.0($0.5{\sim}19.1$) ppbv for the September and October intensives, respectively, which are considerably low, compared to those measured in polluted urban areas around the world including several urban areas of Korea. The diurnal variation showed significant increase of formaldehyde in the daytime suggesting the dominance of formation of formaldehyde due to photochemical oxidation of methane and other hydrocarbons. An increase in the formaldehyde sometimes in the night might be due to an increase in primary source, i.e. traffic emissions. It was also found that rapid increase in formaldehyde levels from 3.0 to 19.1 ppbv in the afternoon on October 20 was due to plumes from burning of agricultural wastes such as rice straw and stubble. It is expected from the measurement data that the constructed dual-channel glass coil sampling system can be utilized for measuring atmospheric concentration of the formaldehyde with high time resolution.

An Electrochemical Evaluation on the Crevice Corrosion of 430 Stainless Steel with Variation of Crevice Wide by Micro Capillary Tubing Method (Micro Capillary Tube 방법을 이용한 430 스테인레스강 틈의 폭변화에 따른 틈부식의 전기화학적 평가)

  • Na, Eun-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.4
    • /
    • pp.250-254
    • /
    • 2003
  • In this study, the IR drop theory was adopted to explain the initiation of crevice corrosion in the framework of IR drop in crevice electrolyte. Furthermore, the electrochemical polarization was measured to study the mechanism of crevice corrosion for type STS430 stainless steel. lest method adopts under condition that the size of specimen is $10\times20\times5mm,\;in\;1N\;H_2SO_4+0.1N\;NaCl$ solution, and the artificial crevice gap sizes are three kinds, the Micro capillary tube size is inner diameter 0.04 mm, outer diameter 0.08 mm. Crevice corrosion is measured under the applied voltage of passivation potential -200mV/SCE, resulted from anodic potentio-dynamic polarization to the external surface along the crevice. The potential difference was measured by depth profile by Micro capillary tube which inserted in the crevice. The obtained results of this study showed that 1) As artificial crevice gap size became narrow, the current density was increased, whereas no crevice corrosion was found in the crevice gap size $3\times0.5\times16mm\;in\;1N\;H_2SO_4+0.1N\;NaCl\;solution\;at\;20^{\circ}C$ 2) potential of the crevice was about from -220 to -358mV which is lower than that of external surface potential of -200mV The results so far confirmes that the potential drop(so-called IR drop) in the crevice is one of the major mechanisms the process of crevice corrosion for 430 stainless steel.

UHV Materials (초고진공계재료)

  • 박동수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.

Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites (맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구)

  • Nguyen, Vanduc;Kim, Dooyoung;Hur, Wonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.28 no.1
    • /
    • pp.38-58
    • /
    • 2018
  • The ventilation system plays a crucial role in underground mine safety. The main objective of the ventilation system is to supply sufficient air to dilute the contaminated air at working places and consequently provide tenable environment during the normal operation, while it also should be capable of controlling the fire propagation and facilitate rescue conditions in case of fire in mines. In this study, a smoke control fan was developed for the auxiliary ventilation as well as the fire smoke exhaust. It works as a free-standing auxiliary fan without tubing to dilute or exhaust the contaminated air from the working places. At the same time, it can be employed to extract the fire smoke. This paper aims to examine the smoke control efficiency of the fan when combined with the current ventilation system in mines. A series of the site experiments and numerical simulations were made to evaluate the fan performance in blind entry development sites. The tracer gas method with SF6 was applied to investigate the contaminant behavior at the study sites. The results of the site study at a large-opening limestone mine were compared with the CFD analysis results with respect to the airflow pattern and the gas concentration. This study shows that in blind development entry, the most polluted and risky place, the smoke fan can exhaust toxic gases or fire smoke effectively if it is properly combined with an additional common auxiliary fan. The venturi effect for smoke exhaust from the blind entry was also observed by the numerical analysis. The overall smoke control efficiency was found to be dependent on the fan location and operating method.

Electrical and Fluidic Characterization of Microelectrofluidic Bench Fabricated Using UV-curable Polymer (UV경화성 폴리머를 이용한 미소유체 통합접속 벤치 개발 및 전기/유체적 특성평가)

  • Youn, Se-Chan;Jin, Young-Hyun;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.475-479
    • /
    • 2012
  • We present a novel polymer fabrication process involving direct UV patterning of a hyperbranched polymer, AEO3000. Compared to PDMS, which is the most widely used polymer in bioMEMS devices, the present polymer has advantages with regard to electrode integration and fast fabrication. We designed a four-chip microelectrofluidic bench having three electrical pads and two fluidic I/O ports. We integrated a microfluidic mixer and a cell separator on the bench to characterize the interconnection performance and sample manipulation. Electrical and fluidic characterization of the microfluidic bench was performed. The measured electrical contact resistance was $0.75{\pm}0.44{\Omega}$, which is small enough for electrical applications, and the pressure drop was 8.3 kPa, which was 39.3% of the value in the tubing method. By performing yeast mixing and a separation test in the integrated module on the bench, we successfully showed that the interconnected chips could be used for bio-sample manipulation.