• 제목/요약/키워드: tubing

검색결과 248건 처리시간 0.022초

구강 결손부에 적용된 요골 유리전완 피부피판 적용례 분석 (Clinical Cases Analysis of Forearm Free Fasciocutaneous Flaps on Oral Cavity Defect Area)

  • 김욱규;이광호;송원욱;황대석;김용덕;신상훈;김종렬;정인교
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권4호
    • /
    • pp.324-331
    • /
    • 2010
  • The radial forearm free flap (RFFF) has become a workhorse flap as a means of reconstructing surgical defects in the head and neck region. We have transferred 12 RFFFs with fasciocutaneous type on oral cavity defects in 12 patients after cancer resection and submucous fibrotic lesion ablation from 2005 to 2007 at Department of oral and maxillofacial surgery, Pusan National University Hospital. We reviewed retrospectively patients' charts and followed up the patients. Clinical analysis on the cases with RFFFs focusing on flap morbidity, indications and available vessels was done. The results of study are follows: 1. RFFF could be applied for all kind of defects after resection of tongue, floor of mouth, buccal mucosa, denuded bone of palate, maxilla, and mandible. 2. All free flaps could be used for primary reconstruction. The survival rate of 12 RFFFs was 92%. Partial marginal loss of the flaps was shown as 3 cases among 12 cases. Large size-vessels like superior thyroid artery, facial artery, internal jugular vein were favorable for microvascular anastomosis. 3. Parenteral nutrition instead of nasal L-tube also can be favorable for postoperative a week for better healing of the flap if the patients couldn't be tolerable with nasal tubing. 4. Donor sites with thigh skin graft were repaired with wrist band for 2 weeks. The complications included scarring, abnormal sensation on hand, and reduced grip strength in few patients, but those didn't induce major side effects. 5. Most RFFFs were well healed even if mortality rate of cancer patients was shown as 50% (5/10 persons). The mortality of patients was not correlated with morbidity of the flaps. We could identify the usefulness of RFFF for restoration of oral function, esthetics if the flap design, tissue transfer indications, and well controlled operation are proceeded.

간호사의 정맥주사 관리에 대한 인식과 수행에 관한 연구 (A Study on the Nurse's Recognition and Performance in Intravenous Therapy Management)

  • 김명희;김윤화
    • 기본간호학회지
    • /
    • 제5권2호
    • /
    • pp.207-224
    • /
    • 1998
  • The purposes of this study were to identify nurse's recognition and performance and to represent the factors of hindrance in the IV therapy management. The subjects were 420 nurses who worked at five general hospitals in Pusan. Tha data were collected using a questionnaire and the period of data collection was from January 1 to January 31, 1998. The instrument for this study was made by author oneself on the basis of guidelines Simmons et al', CDC' Stanley' and Kurdi' guideline, Cllinical Nurse's Association' that consist of 68 items for 5 fields ; pre-injection, just before-injection, needle-injection, during injection, post-injection field. Cron-bach Alpha coefficient of recognition and performance in the IV therapy management was .93 and .87. The datas were analized by a SPSS program using frequency, percent, paired t-test, t-test and oneway ANOVA. The results obtained were as follows : 1. The mean score of recognition in IV therapy management was significantly higher than that of performance(t=5.86, P<.001). 2. The items of lower than mean score of each fields in performance were the identification of drugs, hands washing, patient teaching about medication, disinfectional methods of the injection site and the rubber stopper in bottle, the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, use of tape and armboard, changing the IV tubing, labeling the dressing over the injection site, observation and recordings of patient's condition after medication and confirmation of the needle length at the needle removal. 3. The factors of hindrance in IV therapy were 'having no time', 'insufficiency of goods', 'unknowing of methods', 'no disadvantage', and 'factors of doctor's doing'. The most important factor was 'have no time', especially item of hands washing. The other factors of hindrance showed high frequency in the following items ; 'insufficiency of goods' in the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, 'unknowing of methods' in the certification of drugs compatibility, 'no disadvantage' in the labeling the dressing over the injection site, and 'factors of doctor's doing' in the changing the subclavian catheter dressing and checking the glucose level during the TPN infusion. In conclusion, there is necessity of educational program which can improve the nurse's knowledge of drugs, disinfection methods, comfort of patient and recordings in IV therapy management and alternative plan which are political and financial aids such as setting up the sink, giving of paper towels and necessary goods in the IV therapy for reducing the factors of hindrance for IV therapy management.

  • PDF

$8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발 (Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.184-190
    • /
    • 2008
  • 원전 증기발생기 전열관의 건전성을 평가하기 위해서 여러 가지 와전류검사 기법이 적용되고 있다. 이와 같은 와전류검사 기법중에서 보빈탐촉자 기법은 전열관에 발생할 수 있는 축방향균열, 마모 검사에 적용하고 있으며, MRPC 기법은 튜브시트 상단 및 곡관부위 균열의 정밀검사에 적용된다. 원전 증기발생기 전열관의 설치공정 혹은 운전중에 전열관에 덴트(dent, 혹은 ding) 및 벌지(bulge)가 형성될 수 있으며, 와전류검사에서 이러한 지시는 결함으로 간주하지 않기 때문에 일정 크기 이상의 지시만 검사보고서에 기록하여 관리하고 있다. 이러한 지시는 보빈탐촉자 기법으로 용이하게 검출이 가능하고 보빈단면형상검사에 의해 대략적인 크기의 측정이 가능하지만, 정확한 크기 및 형상은 알 수는 없으므로 본 연구에서는 단면형상검사의 정확도를 증가시키기 위해 $8{\times}1$ 다중코일 탐촉자를 설계 개발하여 그 정확도를 평가하였다. 한편, OPR-1000형 증기발생기 전열관의 튜브시트 확관 천이영역에 형성된 덴트부위에 균열성 결함이 발생할 가능성이 높기 때문에 일부 발전소에서는 예방차원의 슬리빙을 수행하고 있다 이와 같은 슬리빙 대상 전열관 선정시 본 검사기법을 활용하면 유용할 것으로 판단된다.

원전 증기발생기 와전류검사 장치의 전기적 특성 측정 (Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP)

  • 이희종;조찬희;유현주;문균영;이태훈
    • 비파괴검사학회지
    • /
    • 제33권5호
    • /
    • pp.465-471
    • /
    • 2013
  • 원전 증기발생기는 원자로 냉각재 계통에서 발생한 열에너지를 터빈 계통의 주급수에 전달하여 터빈을 회전시키기 위한 증기를 생산하는 일종의 열교환기이다. 증기발생기 전열관의 손상은 증기발생기의 구조적 및 누설 건전성 유지 능력을 저해시키기 때문에 주기적으로 와전류검사를 수행하여 전열관의 건전성을 평가한다. 증기발생기 전열관의 건전성 평가는 보통 원자로 연료 재장전 기간 중에 수행된다. 현재 국내 증기발생기 전열관에 적용되는 와전류검사는 KEPIC 및 ASME 코드 요건에 따라 수행되며, 와전류검사 수행에 필요한 검사 시스템은 와전류검사 장치와 수집된 신호를 평가하기 위한 평가 프로그램으로 구성된다. 검사에 적용되는 와전류검사 시스템을 구성하는 핵심기기인 와전류검사 장치는 ASME 및 KEPIC 코드에서 총 고조파 왜곡율, 입출력 임피던스, 증폭기 직선성 및 안정성, 위상 직선성, 대역폭 및 복조필터 응답, 디지털 변환, 채널 간섭 등과 같은 전기적 특성을 측정하도록 규정하고 있다. 이에 따라 본 논문에서는 국내 최초로 개발한 원전 증기발생기 와전류검사 장치의 전기적 특성 측정을 위한 ASME 및 KEPIC 코드 요건을 설명하고, 이 요건에 따른 증기발생기 와전류검사 장치의 전기적 특성의 측정 결과를 제시하였다.

이중 채널 유리코일 샘플러를 이용한 대기 중 포름알데하이드 측정 (Measurement of Formaldehyde in the Atmosphere using a Dual-channel Glass Coil Sampler)

  • 박승식;홍상범;이재훈;조성용;김승재
    • 한국대기환경학회지
    • /
    • 제22권2호
    • /
    • pp.259-266
    • /
    • 2006
  • A dual-channel glass coil sampling technique was used to measure hourly formaldehyde concentration in the ambient air. The dual-channel coil sampling assembly consists of three parts; an all-pyrex 28-turn coil made of 0.2-cm internal diameter glass tubing for gas-liquid contact and scrubbing of soluble gases, an inlet section upstream of the coil for introducing sample air and scrubbing solution, and a widened glass section downstream of the coil for gas-liquid separation. The scrubbing solution used was a dilute aqueous DNPH (dinitrophenylhydrazine) solution. Hourly concentration of formaldehyde was determined at a Gwangju semi-urban site during two intensive studies between September and October using the dual channel glass-coil/DNPH sampling technique and HPLC (High Performance Liquid Chromatography) analysis. The mean concentration was 1.7($0.4{\sim}4.7$) and 3.0($0.5{\sim}19.1$) ppbv for the September and October intensives, respectively, which are considerably low, compared to those measured in polluted urban areas around the world including several urban areas of Korea. The diurnal variation showed significant increase of formaldehyde in the daytime suggesting the dominance of formation of formaldehyde due to photochemical oxidation of methane and other hydrocarbons. An increase in the formaldehyde sometimes in the night might be due to an increase in primary source, i.e. traffic emissions. It was also found that rapid increase in formaldehyde levels from 3.0 to 19.1 ppbv in the afternoon on October 20 was due to plumes from burning of agricultural wastes such as rice straw and stubble. It is expected from the measurement data that the constructed dual-channel glass coil sampling system can be utilized for measuring atmospheric concentration of the formaldehyde with high time resolution.

Micro Capillary Tube 방법을 이용한 430 스테인레스강 틈의 폭변화에 따른 틈부식의 전기화학적 평가 (An Electrochemical Evaluation on the Crevice Corrosion of 430 Stainless Steel with Variation of Crevice Wide by Micro Capillary Tubing Method)

  • 나은영
    • 전기화학회지
    • /
    • 제6권4호
    • /
    • pp.250-254
    • /
    • 2003
  • 본 연구는 전기화학적 실험측정으로 페라이트계 430스테인레스강 시험편에 인위적으로 틈을 형성시켰다. 부식용액은 IN $H_2SO_4+0.1N\;NaCl$ 전해액을 사용하였고, 각 시험편의 틈의 크기를 달리하였다. 전기화학적 평가방법은 -600mV/5CE에서 정방향으로 +1,200mV/SCE까지 주사속도 600mV/hr로 동전위 분극시험을 실시하여 부식전위, 부동태 전류밀도 등의 부식거동을 분석하였다. 그리고 정전위 분극시험을 실시하여 부동태 구간 전위 -200mV/SCE를 일정하게 인가 한 후, 틈내에 부동태 전류밀도와 틈부식 발생시간을 계측하였다 실험방법에 있어 Microcapillary tube(MCT)를 이용한 방법으로 틈내 각 지점의 전위를 틈 깊이에 따른 틈내부의 전위강하(IR Drop)에 주목하고, 575 430 스테인레스강 금속에 대한 분극특성과 연계하므로써 틈부식의 발생 원인을 '전위의 이동'의 관점에서 규명 하였다.

초고진공계재료 (UHV Materials)

  • 박동수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구 (A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS)

  • 이장우;최충석
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 대전류공급장치(PCITS)에 의해 소손된 강이음쇠형(iron fittings type) 금속플렉시블호스(CSST)의 구조 및 전기적 특성을 해석하였다. CSST는 보호 피막, 튜브, 너트, 클램프 링, 플레어 캡, 소켓, 볼 밸브 등으로 구성되어 있다. CSST의 내전압 평가는 전기 충전부와 비충전부 사이에 교류 전압 220 V를 1분간 인가하여 견뎌야 한다. 직류 500 V에 의한 절연 성능의 평가는 온도 상승 시험 전에 $1M{\Omega}$ 이상, 시험이 끝난 후에는 $0.3M{\Omega}$ 이상을 요구한다. 정상 제품의 평균 저항은 $11.5m{\Omega}$이었으나 PCITS로 130 A를 흘려 소손된 제품의 평균 저항 $11.50m{\Omega}$이었다. 또한 130 A가 약 10 s 흘렀을 때 튜브의 보호 피막이 일부 용융되었고, 검정색의 연기가 발생하였다. 60 s 경과되면 튜브의 대부분이 적색으로 발열되며, 전류가 120 s 흘렀을 때는 적열 범위가 넓어졌다. 95%의 신뢰 구간(CI)의 검증에서 P 값은 0.019로 정규 분포를 갖지 못하였으나 Anderson-Darling (AD) 통계량은 0.896, 표준 편차는 0.5573 등으로 양호한 특성을 나타냈다.

맹갱도 굴진 작업공간내 방재팬의 화재연 배기효율에 관한 현장실험 및 CFD 연구 (Experimental and CFD Study on the Exhaust Efficiency of a Smoke Control Fan in Blind Entry Development Sites)

  • 응우엔반득;김두영;허원호;이창우
    • 터널과지하공간
    • /
    • 제28권1호
    • /
    • pp.38-58
    • /
    • 2018
  • 갱내환기는 지하광산 안전성에 직접적인 영향을 미친다. 갱내환기는 정상시에는 작업공간내 유해물질의 희석을 위한 충분한 량의 급기를 통하여 쾌적한 환경을 유지하는 것이 목적이나 갱내화재와 같은 비상시에는 화재의 확산제어와 구조활동의 지원을 목적으로 한다. 본 연구를 통하여 작업공간 국부환기 뿐만 아니라 화재연 제어를 위한 방재팬을 개발하였다. 방재팬은 풍관없이 가동되며 작업공간내 유해물질의 희석 및 배기 기능을 갖추고 있으며 동시에 화재시 화재연 배기를 목적으로 한다. 본 논문은 개발된 방재팬과 기존 국부팬의 연결 운전을 통한 화재연의 배기효율 연구가 목적이다. 일련의 현장 실험 및 CFD분석을 통하여 맹갱도 작업공간내 방재팬의 화재연 배기효율을 분석하였으며 이를 위하여 SF6 추적가스를 이용한 공간내 기류 및 유해물질 유동을 검토하였다. 대단면 석회석 광산에서 수행한 현장실험과 CFD분석 결과를 비교한 결과, 갱내에서 가장 리스크가 큰 맹갱도 굴진 작업장에서 기존 국부팬 1대와 조합 운전하는 경우, 팬의 설치 위치 및 운전모드의 적절한 선택시에 효율적인 화재연 배기가 가능함을 보였다. 또한 CFD분석을 통하여 벤츄리효과에 의한 배기효율도 확인할 수 있었다. 팬 설치 위치 및 운전모드가 배기효율을 결정하는 가장 중요한 변수임을 보였다.

UV경화성 폴리머를 이용한 미소유체 통합접속 벤치 개발 및 전기/유체적 특성평가 (Electrical and Fluidic Characterization of Microelectrofluidic Bench Fabricated Using UV-curable Polymer)

  • 윤세찬;진영현;조영호
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.475-479
    • /
    • 2012
  • 본 논문은 고차가지구조 폴리머인 AEO3000 를 이용한 UV 광경화 성형 공정을 제안하고자 한다. 이는 기존의 바이오칩 제작에 사용되는 PDMS 보다 경도가 높아 금속 전극 형성이 용이하고 제작 공정이 빠르다는 장점을 갖는다. AEO3000 을 이용하여 본 연구에서는 4 개의 소자를 전기적 유체적으로 연결할 수 있는 전기유체 통합벤치를 제작하고 미소유체 혼합소자와 세포분리소자를 연결, 본 소재와 공정이 바이오칩에 적용될 수 있음을 검증하였다. 전기 유체적 특성 분석 결과 전기적 접촉 저항은 $0.75{\pm}0.44{\Omega}$으로 충분히 작은 값을 보였으며, 유체 접속의 압력 저하는 8.3kPa로 기존의 튜브 연결 방법 대비 39.3% 개선된 값을 보였다. 통합벤치에 접속된 소자에 활성 및 비활성 효모를 주입하여 순차적인 혼합 및 재분리를 성공적으로 구현함으로써 본 소자에 적용된 AEO3000 및 UV 광경화 공정이 생체시료의 처리에 적용될 수 있음을 실험적으로 검증하였다. 이는 바이오 의료 분야에 적용 가능한 생체 친화적 소재의 고속 생산에 응용될 수 있다.