• Title/Summary/Keyword: tube method

Search Result 2,749, Processing Time 0.029 seconds

Determination of Minimal Pressure Support Level During Weaning from Pressure Support Ventilation (압력보조 환기법으로 기계호흡 이탈시 최소압력보조(Minimal Pressure Support) 수준의 결정)

  • Jung, Bock-Hyun;Koh, Youn-Suck;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.380-387
    • /
    • 1998
  • Background: Minimal pressure support(PSmin) is a level of pressure support which offset the imposed work of breathing(WOBimp) developed by endotracheal tube and ventilator circuits in pressure support ventilation While the lower applied level of pressure support compared to PSmin could induce respiratory muscle fatigue, the higher level than PSmin could keep respiratory muscle rest resulting in prolongation of weaning period during weaning from mechanical ventilation PSmin has been usually applied in the level of 5~10 cm$H_2O$, but the accurate level of PSmin is difficult to be determinated in individual cases. PSmin is known to be calculated by using the equation of "PSmin = peak inspiratory flow rate during spontaneus ventilation$\times$total ventilatory system resistance", but correlation of calculated PSmin and measured PSmin has not been known. The objects of this study were firstly to assess whether customarily applied pressure support level of 5~10 cm$H_2O$ would be appropriate to offset the imposed work of breathing among the patients under weaning process, and secondly to estimate the correlation between the measured PSmin and calculated PSmin. Method : 1) Measurement of PSmin : Intratracheal pressure changes were measured through Hi-Lo jet tracheal tube (8mm in diameter, Mallinckroft, USA) by using pulmonary monitor(CP-100 pulmonary monitor, Bicore, USA), and then pressure support level of mechanical ventilator were increased until WOBimp was reached to 0.01 J/L or less. Measured PSmin was defined as the lowest pressure to make WOBimp 0.01 J/L or less. 2) Calculation of PSmin : Peak airway pressure(Ppeak), plateau airway pressure(Pplat) and mean inspiratory flow rate of the subjects were measured on volume control mode of mechanical ventilation after sedation. Spontaneous peak inspiratory flow rates were measured on CPAP mode(O cm$H_2O$). Thereafter PSmin was calculated by using the equation "PSmin = peak inspiratory flow rate$\times$R, R = (Ppeak-Pplat)/mean inspiratory flow rate during volume control mode on mechanical ventilation". Results: Sixteen patients who were considered as the candidate for weaning from mechanical ventilation were included in the study. Mean age was 64(${\pm}14$) years, and the mean of total ventilation times was 9(${\pm}4$) days. All patients except one were males. The measured PSmin of the subjects ranged 4.0~12.5cm$H_2O$ in 14 patients. The mean level of PSmin was 7.6(${\pm}2.5\;cmH_2O$) in measured PSmin, 8.6 (${\pm}3.25\;cmH_2O$) in calculated PSmin Correlation between the measured PSmin and the calculated PSmin is significantly high(n=9, r=0.88, p=0.002). The calculated PSmin show a tendancy to be higher than the corresponding measured PSmin in 8 out of 9 subjects(p=0.09). The ratio of measured PSmin/calculated PSmin was 0.81(${\pm}0.05$). Conclusion: Minimal pressure support levels were different in individual cases in the range from 4 to 12.5 cm$H_2O$. Because the equation-driven calculated PSmin showed a good correlation with measured PSmin, the application of equation-driven PSmin would be then appropriate compared with conventional application of 5~10 cm$H_2O$ in patients under difficult weaning process with pressure support ventilation.

  • PDF

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Clinical Analysis of Disease Recurrence for the Patients with Secondary Spontaneous Pneumothorax (이차성 자연기흉 환자의 재발양상에 관한 분석)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Park, Seong-Sik;Ryu, Jae-Wook;Kim, Hyun-Jung
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.619-624
    • /
    • 2008
  • Background: Secondary spontaneous pneumothorax is caused by various underlying lung diseases, and this is despite that primary spontaneous pneumotherax is caused by rupture of subpleural blebs. The treatment algorithm for secondary pneumothorax is different from that for primary pneumothorax. We studied the recurrence rate, the characteristics of recurrence and the treatment outcomes of the patients with secondary spontaneous pneumothorax. Material and Method: Between March 2005 to March 2007, 85 patients were treated for their first episodes of secondary spontaneous pneumothorax. We analyzed the characteristics and factors for recurrence of secondary spontaneous pneumothorax by conducting a retrospective review of the medical records. Result: The most common underlying lung disease was pulmonary tuberculosis (49.4%), and the second was chronic obstructive lung disease (27.6%), The recurrence rate was 47.1% (40/85). The second and third recurrence rates were 10.9% and 3.5%, respectively. The mean follow up period was $21.1{\pm}6.7$ months (range: $0{\sim}36$ month). For the recurrence cases, 70.5% of them occurred within a year after the first episode. The success rates according to the treatment modalities were thoracostomy 47.6%, chemical pleurodesis 74.4%, blob resection 71% and Heimlich valve application 50%. Chemical pleurodesis through the chest tube was the most effective method of treatment. The factor that was most predictive of recurrence was 'an air-leak of 7 days or more' at the first episode. (p=0.002) Conclusion: The patients who have a prolonged air-leak at the first episode of pneumothorax tend to have a higher incidence of recurrence. Further studies with more patients are necessary to determine the standard treatment protocol for secondary spontaneous pneumothorax.

Variation of Soil Physical Characteristics by Drainage Improvement in Poorly Drained Sloping Paddy Field (배수불량 경사지 논 토양의 배수방법에 따른 토양 물리성 변화)

  • Jung, Ki-Yuol;Yun, Eul-Soo;Park, Chang-Young;Hwang, Jae-Bok;Choi, Young-Dae;Jeon, Seung-Ho;Lee, Hwang-A
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.704-710
    • /
    • 2012
  • The lower portion of sloping paddy fields normally contains excessive moisture and the higher water table caused by the inflow of ground water from the upper part of the field resulting in non-uniform water content distribution. Four drainage methods namely Open Ditch, Vinyl Barrier, Pipe Drainage and Tube Bundle for multiple land use were installed within 1-m position from the lower edge of the upper embankment of sloping alluvial paddy fields. This study was conducted to evaluate soil physical characteristics by drainage improvement in poorly drained sloping paddy field. The results showed that subsurface drainage by Pipe Drainage improves the productivity of poorly drained soils by lowering the water table and improving root zone soil layer condition. In an Pipe drainage plot, soil moisture drained faster as compared to the other drainage methods. Infiltration rate showed high tendency to Piper Drainage method about $20.87mm\;hr^{-1}$ than in Open Ditch method $0.15mm\;hr^{-1}$. And Similarly soil water and degree of hardness and shear strength phase of soil profile showed a tendency to decrease. From the above results, we found that when an subsurface drainage was established with at 1m position from the lower edge paddy levee of the upper field in sloping poorly drained paddy fields Pipe Drainage was the most effective drainage system for multiple land use.

Clinical Analysis of Video-assisted Thoracoscopic Surgery for Spontaneous Pneumothorax - Comparison of Apical Pleurectomy Versus Talc Powder Insufflation (원발성 자연 기흉의 흉강경 수술에서 폐첨부 흉막 박리술과 탈크 흉막 유착술의 비교)

  • 김영대;김병준;조정수;김종원
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.166-172
    • /
    • 2004
  • When compare with blebectomy or bullaectomy simply and pleurodesis together in treatment of primary spontaneous pnevmthorax, the later has been realized as the method that can reduce the recurrent rate after surgical operation. Therefore, in this study, we compared the merits and demerits of the clinical result of chemical pleurodesis that use Talcum powder in pleurodesis and mechanical pleurodesis that use apical pleurectomy and analyzed the reappearance rate etc. Material and Method: The Pleurodesis through the apical pleurectomy and talc powder insufflation had been used as secondary procedure after blebectomy of spontaneous pneumothorax from January 1, 2000 to June 30, 2002. This study consisted of a retrospective review of 68 patients who were treated with apical pleurectomy, and 84 patients treated with talc powder insufflation. We compaired the apical pleurectomy and talc powder insufflation in terms of age, sex, cause of operation, number of used autosuture staple, tine duration of procedure after blebectomy, severity of pain and complication after operation, postoperative air leakage period, duration of chest tube insertion, hospitalization, and recurrence rate of pneumothorax. Result: Time required for secondary procedure was longer in apical pleurectomy than talc powder insufflation. Postoperative pain was more severe in talc powder insufflation than apical pleurectomy. Otherwise there was no significant difference between two methods. Conclusion: Although Talc powder insufflation is more convenient than apical pleurectomy, the difference is not large and, the severity of postoperative pain is worse in talc powder insufflation. Therefore apical pleurectomy can be recommended for the secondary surgical procedure after blebectomy of primary spontaneous pneumothorax can be recommended.

Pulmonary Complications after Surgery for Esophageal Cancer (식도암 수술 후 발생한 호흡기 합병증)

  • Lee, Jang-Hoon;Lee, Jung-Cheul
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.134-139
    • /
    • 2006
  • Background: Complications after surgery for esophageal cancer are various and not rare. Among them, pulmonary complication is well known as one of the most important insults which has negative influence on the postoperative course and results in mortality. So we attempted to analyze the factors which may have relation to postoperative pulmonary complication. Material and Method: The retrospective study was undertaken in 87 patients who underwent curative surgery for esophageal cancer from Jan. 1996 to Aug. 2005. We divided them into two groups, patients with pulmonary complication (group A, n=28), without pulmonary complication (group B, n=59). Statistical analysis was performed with Fisher's exact test. Result: The postoperative pulmonary complication developed in 28 patients ($32\%$). There was no difference between two groups in past medical history, preoperative pulmonary function, surgery time, anastomosis method, pathologic stage, and trial of neoadjuvant therapy. Age and incidence of cervical anastomosis were significantly higher in group A (p=0.001, p=0.023). The rate of routine postoperative ventilator care was significantly higher in group S (p=0.007). Chest tube indwelling time and hospital stay were significantly longer in group A (p=0.011, p=0.001). There were 6 postoperative deaths ($6.8\%$) and 5 deaths were related to pulmonary complication. Pneumonia was the most common cause of death and MRSA (methicillin resistant staphylococcus aureus) was the most common organism in sputum culture. Conclusion: Pulmonary complication after esophageal cancer surgery was the most important cause of death. Pulmonary complication was closely related to patient's age and cervical anastomosis. We think postoperative routine ventilator care is helpful for prevention of pulmonary complications, especially MRSA pneumonia, and reducing mortality.

Clinical Studies on Locally Invasive Thyroid Cancer (국소침범한 갑상선암의 임상적 고찰)

  • Kim Young-Min;Lee Chang-Yun;Yang Kyung-Hun;Rho Young-Soo;Park Young-Min;Lim Hyun-Jun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.236-243
    • /
    • 1998
  • Objectives: Local invasion of the thyroid cancer that is invasion of the upper aerodigestive tract, neurovascular structures of the neck and superior mediastinum, is infrequent and comprises of 1-16% of well-differentiated thyroid cancer. However the proximity of the thyroid gland to these structures provides the means for an invasive cancer to gain ready access into theses structures and when invasion occurs, it is the source of significant morbidity and mortality. So locally invasive thyroid cancer should be removed as much as possible, but still much debates have been exist whether the surgical method should be radical or conservative. This study was desinged to evaluate the clinical characteristics and the surgical treatment of the locally invasive thyroid cancer. Material and Methods: At the department of otorhinolaryngology of Hallym university, 10 patients diagnosed as locally invasive thyroid cancer among the 81 patients treated for thyroid cancer between 1991 to 1997 were retrospectively evaluated. Results: Of the 10 patients, 3 patients had histories of previous surgical treatment with or without radiation or radioactive iodine therapy. The site of invasion of thyroid cancer were trachea(7 cases), recurrent laryngeal nerve(5 cases), mediastinal node(5 cases), esophagus(3cases), larynx(3cases), carotid artery(3 cases), pharynx(l case), and other sites(4 cases). The operation techniques included 1 partial laryngectomy and 1 partial cricoid resection, 2 shavings and 3 window resections of the trachea, 1 sleeve resection of the trachea with end-to-end anastomosis and 1 cricotracheoplasty for tracheal invasion, 2 shavings and 1 partial esophagectomies for esophageal invasion, and 1 wall shaving and 2 partial resections with $Gortex^{\circledR}$ tube reconstruction for carotid artery invasion, and so on. Conclusions: These data and review of literature suggest that the surgical method should be perfomed on the basis of individual condition and complete removal of all gross tumor with preservation of vital structures whenever possible will offer a good result.

  • PDF

The Comparison of Methods Processing Cells Recovered by Bronchoalveloar Lavage (기관지폐포세척액에서 세포수 측정을 위한 처리방법의 비교)

  • Park, Jae-Seuk;Kim, Jae-Yeal;Lee, Gwi-Lae;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.176-183
    • /
    • 1998
  • Background: The total and differential cell count of bronchoalveolar lavage(BAL) fluid are useful assessing activity, prognosis and response to therapy in diffuse interstitial lung disease. But controversy exist as to the appropriate method in processing BAL fluid. Therefore we investigated the effect of gauze filtration, centrifugation and different storage time of BAL fluid on the total and differential cell count. Methods: We obtained BAL fluid from 6 persons with no active lung lesion and divided pooled BAL fluid into several siliconized glass tubes and filtered through 0, 1, 2, 4 folds of cotton guaze(pore size: 1mm), and compared total cell count using hemocytometer after trypan blue staining and differential cell count after Wright-Giemsa staining of cytocentrifuged preparations. And we also counted total and differential cell count after centrifugation(400g for 30 min) and various storage time(2hr, 24hr, and 48hr). Results: There was no difference in total and differential cell count according to folds of gauze filtraion. But without gauze filtration, mucus threads that hampered total and differential cell count were found in 2 cases (33%). Centrifugation resulted in loss of total cell count($24{\pm}18%$) without change in differential cell count. There was no change in total cell count after 2hr storage but significant cell loss was found after 24hr storage time(24hr : $28{\pm}21%$, 48hr : $41{\pm}24%$). However there was no change in differential cell count with 48hr storage time. Conclusion: Total and differential cell count of BAL fluid may be best performed after cotton gauze filtration without centrifugation and within 2 hours.

  • PDF

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.