• Title/Summary/Keyword: tube internal

Search Result 582, Processing Time 0.026 seconds

Development of Magnetic Abrasive Jet Machining System for Precision Internal Polishing of Circular Tubes (원형관의 내면정밀가공용 순환식 자기입자분사가공 시스템 개발)

  • 강윤희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.24-29
    • /
    • 1995
  • A recently developed finishing process using rotating magnetic field is known to be very efficient for the finishing of parts such as vacuum tube, sanitary tube, etc., which are difficult to be finished by the conventional finishing methods as they are generally curbed tubes. But, the finishing system using rotating magnetic field have the defect that is the cross section of workpiece only circle because of internal rotating tool. Therefore, new finishing process of the workpieces which cross section are not circle is important and required. magnetic abrasive jet machining is a new concept finishing process. It is the precision internal finishing method using working fluid mixed with magnetic abrasives, which is jetted into the internal surface of tube. And magnetic poles are equipped on external surface of tube. In this study new concept finishing process or, magnetic abrasive jet machining system was developed. machining condition was predicted using simulation and some characteristics of the finishing process was analyzed.

  • PDF

Analysis of Internal Flow for Component Cooling Water Heat Exchanger in CANDU Nuclear Power Plants (중수로 기기냉각수 열교환기 내부 유동 해석)

  • Song, Seok-Yoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.33-41
    • /
    • 2012
  • The component cooling water heat exchangers are critical components in a nuclear power plant. As the operation years of the heat exchanger go by, the maintenance costs required for continuous operation also increase. Most heat exchangers have carbon steel shells, tube support plates and flow baffles. The titanium tube is susceptible to flow induced vibration. The damage on carbon steel tube support rod and titanium tube around cooling water entrance area is inevitable. Therefore, analysis of internal flow around the component cooling water entrance and tube channel is a good opportunity to seek for failure prevention practice and maintenance method. The numerical study was carried out by FLUENT code to find out the causes of tube failure and its location.

Manufacturing of High-Performance Double Layered Tube with Corrugated Internal Pattern via the Hydroforming Process (액압 성형을 이용한 내부복합파형 고효율 이중관 제조 기술)

  • Han, S. W.;Kim, D. Y.;Moon, Y. H.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.143-150
    • /
    • 2022
  • The purpose of this study was to investigate an innovative hydroforming process for the cost-effective manufacturing of double layered tube with circumferentially corrugated patterns. Conventional double pipe heat exchanger has relatively poor heat transfer efficiency because of the limited contact area resulting from the concentrically arranged simple cylindrical structure. As a promising alternative to enhance heat transfer efficiency, double layered tube with corrugated internal pattern was considered in this study. To fabricate corrugated inner tube, innovative tube hydroforming system was developed. The customized loading paths were established using the simulated forming pressure and contracting stroke at various bar diameters. Experimentally obtained cross-sectional profiles were analyzed to evaluate the reliability and applicability of the hydroformed tube with various patterns. The results demonstrate that the proposed hydroforming process can be a feasible alternative for manufacturing high-performance double-tube heat exchangers.

Study on Surface Roughness due to WA-BF-Fe Grain for Internal Magnet-abrasive Finishing Apparatus of STS 304 Pipe (STS 304 파이프 내면의 자기연마법에 있어서 WA-BF-Fe 자성입자가 표면거칠기에 미치는 영향)

  • 김용수;정윤중;김희남;김순채;배재만
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.35-40
    • /
    • 2001
  • An internal finishing process applying Magnetic Abrasive Finishing (MAF) was proposed to produce smooth inner surfaces of tubes at a high rate. Since this process uses the tube rotation system, it has been considered applicable only to tubes which are rotatable at high speeds. Here development of the stainless tube(STS 304) rotation system to extend the scope of the application of the internal finishing process applying MAF was made. By the stainless tube(STS 304) rotation system, the abrasive magnetically attracted by the poles is rotated along the inner surface of the tube by magnetic force together with fixed poles, finishing the inner surface of the tube. The main results obtained are as follows : 1) The magnet abrasive finishing minimized influence due to external force because non-contact finishing, 2) The profile of surface roughness decreased very good in 11.4m/min range because abrasive size and speed, 3) The profile of surface roughness by flux density decreased in finishing speed 28m/min, 4) The profile of surface roughness by fled rate decreased in 0.16mm/rev and 0.18mm/rev.

  • PDF

Study on the Tube Reducing Process Subject to Internal Pressure (내압을 받는 튜브 리듀싱에 관한 연구)

  • Lee, Hang-Soo;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.4
    • /
    • pp.72-83
    • /
    • 1987
  • In axisymmetric tube reducing process for thin sheet metal tubes, the reduction ration of diameter is an important factor in the process design. For very thin sheet metal tubes, tube reducing cannot be successfully employed due to wrinkling of the edge portion of a tube as well as due to buckling of its rest portion. In the present study, thin sheet metal tubes are subjected to internal pressure during the tube reducing process in order to increase the forming limits. Analysis is made for the sound flow deformation in nonsteady tube reducing considering the normal anisotropy. Experiments are carried out for brass tubes. The present study is shown to give an effective guide line in designing the tube reducing process for very thin-walled sheet metal tubes. Hpwever, it is suggested that an analysis for instability should be made to design the process more effectively.

  • PDF

Behaviors of Internally Confined Hollow Reinforced Concrete Piers by Thickness of Internal Steel Tube (내부 강관 두께에 따른 내부 구속 중공 RC 교각의 거동)

  • Choi, Jun-Ho;Han, Taek-Hee;Yi, Gyu-Sei;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.333-338
    • /
    • 2007
  • An infernally confined hollow reinforced concrete pier (ICH RC pier) is hollow RC pier which has a internal steel tube to enhance its ductility and stiffness by internal confinement. In this study, the internal steel tube were changed to investigate the behavior of ICH RC pier. The behavior of internally confined hollow reinforced concrete piers were evaluated with safety ratio, ductility, total material cost, the total weight of the pier, etc. As a result of analytical study, the usage of a minimum necessary thickness of the internal steel tube the most effective. The ICH RC pier has decrease of weight compare to Solid RC pier.

  • PDF

A Case Report about Diarrhea of Soeumin Caused by Tube Feeding Treated with Korean Medicinal Treatment (경관 영양으로 유발된 소음인 설사에 관한 한방 처치 1례)

  • Ha, Jeong-been;Lee, Su-jung;Lew, Jae-hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objectives: This study aimed to investigate the effect of Soeumin-Seonghyangjeongki-san on diarrhea with tube feeding causing mental deterioration induced by subdural hemorrhage (SDH) in an 83-year-old male patient. Methods: The patient was treated with Soeumin-Seonghyangjeongki-san. His symptoms were assessed using the Bristol stool form index, the King's Stool Chart, and records of stool state. The treatment was executed for one week from September 10, 2018 to September 16, 2018. The patient was observed during that same period. Results: After being treated with Soeumin-Seonghyangjeongki-san for seven days, the patient's diarrhea symptoms were evaluated using the Bristol stool form index, the King's Stool Chart, and records of stool state. After the treatment, the results of all three evaluation methods showed that the patient's condition had improved. Conclusions: The results suggest that Soeumin-Seonghyangjeongki-san can be a valuable option for treating diarrhea with tube feeding causing mental deterioration induced by SDH.

Cavitary Lung Abscess Mistaken for Pneumothorax after Drainage of Pus (배농후 기흉으로 오인된 공동성 폐농양)

  • Hong, Bum-Kee;Chang, Jung-Hyun;Kim, Se-Kyu;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.449-453
    • /
    • 1993
  • A 64-year-old male was admitted due to abruptly developed, severe dyspnea via local clinic. He had been a heavy smoker and alcoholic for a long time. Chest PA showed huge haziness in right upper lung field. Sputum culture for bacteriology was positive for Klebsiella pneumoniae. Immediately, appropriate antibiotics were administered and artificial ventilation was started. On 40th hospital day, simple chest roentgenogram taken due to sudden aggravated dyspnea showed marked hyperlucency in right upper lung field, suggestive of rupture of abscess cavity and resultant pneumothorax. At that time, chest tube was inserted but air leakage from the chest tube persisted. Chest CT scan taken after chest tube insertion showed the tube inserted into a thin-walled cavity in the above lesion. on 84th hospital day, right upper lobectomy with decortication was performed. Pathologically, cavittary lung abscess was diagnosed on the findings of partial re-epithelialization of ciliated columnar epithelium with severe pulmonary vascular occlusion and extensive fibrous pleural adhesions.

  • PDF

A Case of Focal Reexpansion Pulmonary Edema after Chest Tube Insertion (흉관 삽관 후 발생한 국소성 재팽창성 폐부종 1예)

  • Chung, Hye Kyoung;Jang, Won Ho;Kim, Yang Ki;Lee, Young Mok;Hwang, Jung Hwa;Kim, Ki-Up;Uh, Soo-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.59-62
    • /
    • 2009
  • Reexpansion pulmonary edema is not a common phenomenon after chest tube insertion but some reports from 0% to 14%. There are various resulting complications, including acute respiratory distress syndrome. We report a case of focal reexpansion pulmonary edema after chest tube insertion. A 49-year-old male came to the hospital due to ongoing dyspnea and left chest pain for 3 days. On chest X-ray, the patient had a left pneumothrax. We planned to insert a chest tube for symptom relief. To determine whether or not the chest had expanded as a result of the chest tube insertion, the patient underwent repeated chest X-rays the following day. The patient experienced brief respiratory symptoms upon initial suction; a chest PA showed patchy consolidated infiltration at the inserted site. After 5 days of conservative management, the recovered completely.

Loading Path Optimization in Aluminum Tube Hydroforming using Response Surface Method (반응표면법을 이용한 알루미늄 튜브 하이드로포밍의 하중경로 최적화)

  • Lim, H.T.;Kim, H.J.;Kim, H.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.314-317
    • /
    • 2007
  • Automotive rear subframe of aluminum tube was developed by using hydroforming process, based on the numerical analysis and physical tryouts. In the previous study, the effect of prebending was evaluated on the basis of forming limit diagram which had been obtained from free bulging, T-shape forming and cross-shape forming, using the developed tube hydroformability testing system. In order to get the sound products, appropriate internal pressure is to be imposed corresponding to the axial feeding. In this study, the loading path, the combination of internal pressure and axial feeding during the process, was optimized to ensure minimum thickness variation and dimensional accuracy, by using response surface method.

  • PDF