• Title/Summary/Keyword: true length

Search Result 172, Processing Time 0.029 seconds

Dimensional Measurement of Spent Fuel Assemblies Using Image Processing Technique (영상처리기술에 의한 사용후핵연료 집합체의 제원 측정)

  • Koo, Dae-Seo;Park, Seong-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • A pool image processing measurement method has been developed to improve the examination efficiency and to minimize the errors of dimensional measurements of spent fuel assemblies in pool. Diameter and length measurements of mock-up fuel rods using the image processing system are $-0.24{\pm}0.03mm,\;0.34{\pm}0.06mm$ on the basis of the true value and their maximum errors are within -0.3 and 0.4mm, respectively, According to the result of dimensional measurement of spent fuels in pool, the upper and lower part diameter and mid part diameter of fuel rods of the J44 fuel assembly irradiated for 2 cycles in the Kori-2 nuclear reactor were decreased by about 2.0 and 3.0% in comparison with design values, respectively. The length of fuel rods was elongated by about 0.4%. The change behavior of diameter and length. of fuel rods of the F02 fuel assembly irradiated for 3 cycles in the Kori-1 nuclear reactor showed a trend similar to the results of J44.

Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator

  • Uzunoglu, Emel;Eymirli, Ayhan;Uyanik, Mehmet Ozgur;Calt, Semra;Nagas, Emre
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.44-49
    • /
    • 2015
  • Objectives: This study compared the ability of several techniques to remove calcium hydroxide (CH) from the root canal and determined the influence of CH residues on the accuracy of the electronic apex locator. Materials and Methods: Root canals of 90 human maxillary lateral incisors with confirmed true working length (TWL) were prepared and filled with CH. The teeth were randomly assigned to one of the experimental groups according to the CH removal technique (n = 14): 0.9% saline; 0.9% saline + master apical file (MAF); 17% ethylenediamine tetraacetic acid (EDTA); 17% EDTA + MAF; 5.25% sodium hypochlorite (NaOCl); 5.25% NaOCl + MAF. Six teeth were used as negative control. After CH removal, the electronic working length was measured using Root-ZX (Morita Corp.) and compared with TWL to evaluate Root-ZX accuracy. All specimens were sectioned longitudinally, and the area of remaining CH (CH) and total canal area were measured using imaging software. Results: The EDTA + MAF and NaOCl + MAF groups showed better CH removal than other groups (p < 0.05). Root-ZX reliability to prevent overestimated working length to be > 85% within a tolerance of ${\pm}1.0mm$ (p < 0.05). There was strong negative correlation between amount of CH residues and EAL accuracy (r = -0.800 for ${\pm}0.5mm$; r = -0.940 for ${\pm}1.0mm$). Conclusions: The mechanical instrumentation improves the CH removal of irrigation solutions although none of the techniques removed the dressing completely. Residues of CH medication in root canals affected the accuracy of Root-ZX adversely.

Germination, Seedling Emergence, and Growth of Burcucumber Affected by Maturity and Size (안동대목 종자의 크기와 등숙 정도에 따른 발아.유묘 출현 및 생장)

  • 강진호;전병삼;윤수영;이상우;정종일
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.3
    • /
    • pp.152-155
    • /
    • 2003
  • Burcucumber (Sicyos angulatus L.), used as a medicinal or rootstock for cucurbitaceous crops have shown high variation in seed maturity and size. This study was carried out to determine the effect of seed maturity and size on seed germination, seedling emergence and growth of burcucumber, Seeds collected from a native site were divided into small, medium and large ones after sorted to mature and immature ones. Their germination, seedling emergence and growth were done in indoor and a green house. Mature seeds showed higher germination and seedling emergence rate than immature ones. Regardless of their maturity, medium. and small seeds showed higher germination rate than large ones. Medium and large seeds, however, had the greatest and the least seedling emergence, respectively. Seedling height, number of true leaves areas of cotyledons and true leaves except hypocotyl length were increased with increased seed size although were not affected by the maturity. Cotyledon, leaf, hypocotyl, root and their total dry weights were greater in large mature seeds than large immature ones while increased with increased seed size in both maturities.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Essential Factors in Predicting the Need for Angio-Embolization in the Acute Treatment of Pelvic Fracture with Hemorrhage

  • Yang, Seok-Won;Park, Hee-Gon;Kim, Sung-Hyun;Yoon, Sung-Hyun;Park, Seung-Gwan
    • Journal of Trauma and Injury
    • /
    • v.32 no.2
    • /
    • pp.101-106
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the essential factors for prompt arrangement of angio-embolization in patients with pelvic ring fractures. Methods: A total of 62 patients with pelvic ring fractures who underwent angio-embolization in Dankook University Hospital from March 2013 to June 2018 were retrospectively reviewed. There were 38 men and 24 women with a mean age of 59.8 years. The types of pelvic ring fractures were categorized according to the Tile classification. Patient variables included sex, initial hemoglobin concentration, initial systolic blood pressure, transfused packed red blood cells within 24 hours, Injury Severity Score (ISS), mortality rate, length of hospital stay, and time to angio-embolization. Results: The most common pelvic fracture pattern was Tile type B (n=34, 54.8%). The mean ISS was $27.3{\pm}10.9$ with 50% having an $ISS{\geq}25$. The mean time to angio-embolization from arrival was $173.6{\pm}89minutes$. Type B ($180.1{\pm}72.3minutes$) and type C fractures ($174.7{\pm}91.3minutes$) required more time to angio-embolization than type A fractures ($156.6{\pm}123minutes$). True arterial bleeding was identified in types A (35.7%), B (64.7%), and C (71.4%). Conclusions: It is important to save time to reach the angio-embolization room in treating patients with pelvic bone fractures. Trauma surgeons need to consider prompt arrangement of angio-embolization when encountering Tile type B or C pelvic fractures due to the high risk of true arterial bleeding.

A comparative study of the physical and cooking characteristics of common types of rice collected from the market by quantitative statistical analysis

  • Evan Butrus Ilia;Mahmood Fadhil Saleem;Hamed Hassanzadeh
    • Food Science and Preservation
    • /
    • v.30 no.4
    • /
    • pp.602-616
    • /
    • 2023
  • Fifteen types of rice collected from Kurdistan region-Iraq were investigated by principal component analysis (PCA) in terms of physical properties and cooking characteristics. The dimensions of evaluated grains correspond to 5.05-8.75 mm for length, 1.54-2.47 mm for width, and 1.37-1.95 for thickness. The equivalent diameter was in the range of 5.23-10.03 mm, and the area took 13.30-28.25 mm2. The sphericity analysis values varied from 0.32 to 0.56, the aspect ratio from 0.17 to 0.39, and the volume of the grain was measured in the range from 4.48 to 17.74 mm3, hectoliter weight values were 730-820 kg/m3, and true density from 0.6 to 0.96 g/cm3. The broken grain ratio was 1.5-18.3%, thousand kernel weight corresponded to 15.88 to 22.42 g. The water uptake ratios for 30 min of soaking were increased at 60℃ compared to 30 and 45℃. The PCA was used to study the correlation of the most effective factors. Results of PCA showed that the first (PC1) and second (PC2) components retained 63.4% and 34.8% of the total variance, which PC1 was mostly related to hectoliter, broken ratio, and moisture content characteristics while PC2 was mostly concerned with hardness and true density. For cooking properties, the PC1 and PC2 retained 88.5% and 9.3% of the total variance, respectively. PC1 was mostly related to viscosity, spring value, and hardness after cooking, while PC2 was mostly concerned with spring value, hardness before cooking, and hardness after cooking.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Study on the Design of a Beta Ray Sensor Reducing Digital Switching Noise (디지털 스위칭 노이즈를 감소시킨 베타선 센서 설계)

  • Kim, Young-Hee;Jin, Hong-Zhou;Cha, Jin-Sol;Hwang, Chang-Yoon;Lee, Dong-Hyeon;Salman, R.M.;Park, Kyung-Hwan;Kim, Jong-Bum;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.403-411
    • /
    • 2020
  • Since the analog circuit of the beta ray sensor circuit for the true random number generator and the power and ground line used in the comparator circuit are shared with each other, the power generated by the digital switching of the comparator circuit and the voltage drop at the ground line was the cause of the decreasein the output signal voltage drop at the analog circuit including CSA (Charge Sensitive Amplifier). Therefore, in this paper, the output signal voltage of the analog circuit including the CSAcircuit is reduced by separating the power and ground line used in the comparator circuit, which is the source of digital switching noise, from the power and ground line of the analog circuit. In addition, in the voltage-to-voltage converter circuit that converts VREF (=1.195V) voltage to VREF_VCOM and VREF_VTHR voltage, there was a problem that the VREF_VCOM and VREF_VTHR voltages decrease because the driving current flowing through each current mirror varies due to channel length modulation effect at a high voltage VDD of 5.5V when the drain voltage of the PMOS current mirror is different when driving the IREF through the PMOS current mirror. Therefore, in this paper, since the PMOS diode is added to the PMOS current mirror of the voltage-to-voltage converter circuit, the voltages of VREF_VCOM and VREF_VTHR do not go down at a high voltage of 5.5V.

Effect of Shading Using Different Colored Fabrics on Burcucumber(Sicyos angulatus L.) Seedling Growth and Cotyledon Chlorophyll Content (차광막의 색상이 안동대목 유묘의 생장과 자엽의 엽록소 함량에 미치는 영향)

  • Cho, Gun-Hyun;Jeon, Seung-Ho;Lee, Chang-Woo;Kim, Hong-Young;Kang, Jin-Ho
    • Korean Journal of Plant Resources
    • /
    • v.20 no.5
    • /
    • pp.466-470
    • /
    • 2007
  • Nowadays burcucumber(Sicyos angulatus L.) has been widely used as a rootstock of Cucurbitaceae. The study was done to examine the effects of shading with different colored fabrics(white, red and aluminum-coated) on growth and cotyledon chlorophyll content of its seedling. Shading with the white colored fabric lengthened seedling height and hypocotyl length, but shading with the red colored fabric enlarged true leaf area. Total dry weight of each seedling was decreased in the order of no shading, white, red and aluminum, in which resulted from reductions of cotyledon dry weight in white colored fabric, cotyledon and true leaf dry weight in red colored fabric, and dry weight of cotyledon, true leaf and root in aluminum colored fabric. Cotyledon chlorophyll content was reduced by shading treatments although the 3 shading treatments showed nearly same content.

Sequence analysis of partial LSU rDNA of three Alexandrium species (Dinophyceae) hitherto unreported

  • Kim, Keun-Yong;Makoto Yoshida;Kim, Chang-Hoon
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.35-35
    • /
    • 2003
  • We, for the first time, reported molecular sequences of large subunit ribosomal DNA Dl-D3 region of A. hiranoi, A. leei and A. satoanum hitherto unreported. In addition, this study presented the full-length sequences of A. affine, A. fraterculus, A. catenella and A. tamarense occurring in Korean coastal waters. In total, 17 Alexandrium morphospecies were subjected to the phylogenetic analysis using the Maximum-likelihood (ML) method. The alignment result of sequences of A. hiranoi and A. pseudogonyaulax showed that there were only two substitutions without length heterogeneity implying their genetic affiliation. In ML tree, A. leei formed a deeply diverging branch probably because of the accelerated evolutionary rate, and its phylogenetic position was so ambiguous to resolve the phylogenetic relationship to the residual taxa. An A. satoanum culture showing morphological variation in the sulcal plate formed an independent divergent branch with consistent sister relationship to A. hiranoi/A. pseudogonyaulax clade supported by the high posterior probability (PP) value. Blast search in GenBank showed the sequence data of A. affine, A. fraterculus, A. catenella and A. tamarense corresponded to their morphological species designation. In ML tree, Alexandrium species were commonly split into four main clades. The inter-clade relationships were not clear and usually supported by the week PP values. In general, the sulcal plate of Alexandrium species seemed to reflect the true phylogeny at the main clade level, and the connection between the 1 and the apical pore complex seemed to reflect the phylogeny at the subclade level.

  • PDF