• Title/Summary/Keyword: triac

Search Result 51, Processing Time 0.027 seconds

A study on characteristics of three phase induction motor with stator voltage control by symmetrically triggered triacs (Triac을 이용한 삼상유도전동기의 일차전압평형제어에 따른 특성 연구)

  • 노창주;유춘식;정경열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.72-84
    • /
    • 1984
  • In this paper, the characteristics relating to the stator voltage control of a small three phase squirrel cage induction motor by means of symmetrically trggered triacs instead of antiparallel SCR's is described. A complete model of the system with 220V, $3{\phi}$, 1HP motor and triac gate control circuit has been designed and tested in the laboratory, and the experimental results are compared with the numerical values. As a result of the above investigation, it is found that the range of induction motor speed control by stator voltage control is narrow.

  • PDF

A study on the adjusting output energy of the CO2 laser controlled directly in AC power line (상용전원을 제어하는 CO2레이저의 출력 조절에 관한 연구)

  • Jeong, Jong-Jin;Lee, Im-Geun;Choi, Jin-Young;Park, Sung-Jin;Song, Gun-Ju;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2138-2139
    • /
    • 2005
  • We demonstrate a simple CO2 laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from 45 to 135. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of 90.

  • PDF

A Study on the Soft Starting Switch of Single Phase Condenser Induction Motor Using TRIAC (트라이액을 이용한 단상 유도전동기의 Soft Starting Switch에 관한 연구)

  • 강응석;신대철;최종문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.97-103
    • /
    • 2004
  • In general the starting current of single phase induction motor is 3 to 6times of the rated current It make flickering an electric lamp, dispersion a TV screen, insulation destructing an electric motor and momentary blazing of house wiring. Thus it happens losing an electric power loss and reducing an efficiency and a life of home electrical apparatus. In this paper, we proposed the method of reducing staring current with 3.7(%) using TRIAC and ACCT(alternated current transformer) in order to improve the above problem And also we verified semipermanent system with using semiconductor element.

the Design of Phase Angle Controller for Minimum Harmonic Current (최저 고조파전류발생 위상각제어기의 파라미터 설계)

  • Lim, H.W.;Park, S.K.;Cho, G.B.;Baek, H.L.;Kim, P.H.;Jang, Y.H.;Park, H.A.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.342-344
    • /
    • 2001
  • The single phase control system may become noisy when speed is controlled with a conventional triac AC controller. This paper describes that a simple modification to the triac circuit is shown to reduce the effect, at the cost of increased power dissipation in the controller.

  • PDF

A Novel Switching Mode for High Power Factor Correction and Low THD

  • Park, Gyumin;Eum, Hyunchul;Yang, Seunguk;Hwang, Minha;Park, Inki
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.210-212
    • /
    • 2018
  • A new switching mode has been proposed to obtain high power factor and low THD in single stage AC-DC converter. The conventional voltage mode control in critical conduction mode distorts input current shape with poor THD in flyback topology. Once TRIAC dimmer is connected, visible flicker in the LED lamp is easily detected due to a lack of TRAIC holding current near the input voltage zero cross. The newly proposed method can shape the input current by providing a desired reference voltage so that low THD is obtained by ideal sinusoidal input current in case of no dimmer connection and flat input current performs good TRIAC dimmer compatibility in phase-cut dimming condition. To confirm the validity of the proposed method, theoretical analysis and experimental result from 8W dimmable LED lighting system are presented.

  • PDF

Changes in Poly ADP Ribose Polymerase Immune Response Cells of Cerebral Ischaemia Induced Rat by Transcranial Magnetic Stimulation of Alternating Current Approach

  • Koo, Hyun-Mo;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.357-364
    • /
    • 2014
  • This study examined effect of a transcranial magnetic stimulation device with a commercial-frequency approach on the neuronal cell death caused ischemia. For a simple transcranial magnetic stimulation device, the experiment was conducted on an ischemia induced rat by transcranial magnetic stimulation of a commercial-frequency approach, controlling the firing angle using a Triac power device. The transcranial magnetic stimulation device was controlled at a voltage of 220 V 60 Hz and the trigger of the Triac gate was varied from $45^{\circ}$ up to $135^{\circ}$. Cerebral ischemia was caused by ligating the common carotid artery of male SD rats and reperfusion was performed again to blood after 5 minutes. Protein Expression was examined by Western blotting and the immune response cells reacting to the antibodies of Poly ADP ribose polymerase in the cerebral nerve cells. As a result, for the immune response cells of Poly ADP ribose polymerase related to necrosis, the transcranial magnetic stimulation device suppressed necrosis and had a protective effect on nerve cells. The effect was greatest within 12 hours after ischemia. Therefore, it is believed that in the case of brain damage caused by ischemia, the function of brain cells can be restored and the impairment can be improved by the application of transcranial magnetic stimulation.

A Study on LED Driver Compatible with Triac-dimmer Employing Active Bleeder (능동 블리더 회로를 적용한 조광기 호환용 LED 구동회로에 관한 연구)

  • Yeom, Bong-Ho;Kim, Teak-Woo;Kim, Ju-Rae;Hong, Sung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.159-160
    • /
    • 2013
  • 본 논문에서는 백열등 조도 조절용 조광기에 호환 가능한 LED 구동회로를 제안한다. 조광기와 일반적인 LED 구동회로를 연결할 경우 트라이악(Triac)의 오동작에 의해 플리커(Flicker) 현상이 발생하는 문제점을 지니고 있다. 트라이악의 오동작을 방지하기 위해서는 트라이악에 일정 크기 이상의 전류가 인가되어야 하며 이를 만족하기 위한 조광기 호환회로가 필수적이다. 이러한 호환회로로써 수동 블리더(Passive Bleeder)는 전 동작 구간에서 전력소모가 발생하는 단점을 지니고 있다. 본 논문의 제안회로는 역률 만족을 위 해 Valley-fill 회로를 적용하였으며 트라이악의 오동작 시점을 정확히 검출하여 새로운 방식의 능동 블리더(Active Bleeder)를 적용함으로써 조광기의 오동작을 방지하면서 수동 블리더에 비해 효율이 개선되는 장점을 지닌다. 또한, Valley-fill과 인덕터를 적용한 1단 구성으로 효율개선 및 역률 개선의 장점과 입력 전류 리플의 감소로 인한 EMI 노이즈 저감 효과를 나타낸다. 본 논문에서는 제안된 회로의 타당성을 검증하기 위하여 13W급 조명용 LED 구동회로의 시작품 제작을 통해 그 우수성을 확인한다.

  • PDF

Deduction of Optimal Conditions for Acrylic Etching Technique by using CO2 Laser

  • Kim, Hee-Je;Song, Keun-Ju;Park, Sung-Jin;Seo, Hyun-Woong;Kim, Ho-Sung;Choi, Jin-Young;Park, Sung-Joon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.106-111
    • /
    • 2007
  • Laser cutting with the micro-control technique has great potential to be employed for acrylic machining. In this paper, the optimal conditions of acrylic etching have been investigated. The three parameters such as laser power, moving velocity, and thickness of acrylic are experimented to find out optimal conditions. From these experimental results, we have known that it is very important to control accurate power by the TRIAC switching technique. The best condition of acrylic etching is performed 10 Wand 72 mm/sec at the plastic thickness of 1.33 mm. The other case is performed 10 W and 48 mm/sec, and 12 W and 56 mm/sec at the acrylic thickness of 2.00mm, respectively.

A Method of Reliability Improvement of TRIAC for Incandescent Lamp Switching (백열전구 스위칭용 트라이액의 신뢰성 향상 방안)

  • 김순기
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.44-49
    • /
    • 1997
  • 백열전구 시스템의 설계에서 스너버 회로의 설계는 백열전구의 특성을 고려하는 것이 대단히 중요하다. 특히 서지전압 유입시 백열전구의 과도특성은 설계시 보다 많은 설계사양들을 제공하게 된다. 본 논문에서는 서지전압 유입시 과도특성에 근거한 백열전구의 동작모델을 등가회로로 나타냈다. 이 모델은 제조사가 다른 백열전구에도 광범위한 적용이 가능하다. 본 논문에서 제시한 모델이 실질적으로 효용성이 있음을 나타냈으며, 스너버 회로와 리액턴스(LS) 설계시 백열전구의 서지전압 및 과도 특성에 의한 최적설계를 더욱 명확히 할 수 있다.

  • PDF

A Study on the Adapting for Interrupting Capacity Augmentation of Circuit Breaker (차단기의 차단합성성대기적에 관한 연구)

  • 황석영;조무제
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.299-309
    • /
    • 1984
  • This paper proposes the adapter for interrupting capacity augmentation of circuit breaker which can be applied in case of shortage in a existing circuit breaker's interrupting capacity due to utility system extension. The adapter utilizes two winding type of reactor instead of single winding type of reactor and the control of 2ry circuit is excuted by a triac interlocked with the system protective relays actuation so as to cut out the reactor by short circuit of the 2ry winding in normal situation and to cut in the reactor by open circuit of the 2ry winding in abnomal situation such as short circuit accident. As a result of the theoritical analysis and experiment, it is proved that the adaptor can reduce the voltage crop and iron loss due to the reactor signigicantly in normal system condition and do a role of reactor upon the power system accident.