• Title/Summary/Keyword: trend line

Search Result 783, Processing Time 0.028 seconds

Genetic Parameters and Annual Trends for Birth and Weaning Weights of a Northeastern Thai Indigenous Cattle Line

  • Intaratham, W.;Koonawootrittriron, S.;Sopannarath, P.;Graser, H.-U.;Tumwasorn, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.4
    • /
    • pp.478-483
    • /
    • 2008
  • Records of a Northeastern Thai indigenous cattle line population were used to estimate genetic parameters and annual trends for calf weights. The data set comprised records of 1,922 and 1,489 animals for birth and weaning weight, respectively born from 1993 to 2004. A bivariate analysis was carried out for variance and covariance components estimations using average information restricted maximum likelihood procedure. Average estimated breeding value and maternal breeding value of the animals born in 1993 were set to zero as a base group. Genetic trends of each trait were calculated by regressing average estimated breeding values and maternal breeding values on birth year of calves. Phenotypic trends for each trait were calculated by regressing the yearly adjusted weight on birth year of calves. The results revealed that the estimate of direct heritability, maternal heritability and maternal permanent environmental variance as a proportion of phenotypic variance for birth and weaning weight was 0.40, 0.14 and 0.04; 0.27, 0.05 and 0.23, respectively. Direct heritability was moderately heritable and genetic improvement through selection can be achieved. The estimate of phenotypic, direct genetic, maternal genetic and maternal permanent environmental correlation between birth and weaning weight was 0.48, 0.65, 0.98 and 0.73, respectively. The phenotypic trend, genetic trends of estimated breeding value and maternal breeding value for birth weight was 0.18, 0.04 and 0.01 kg/year, respectively. The phenotypic trend, genetic trends of estimated breeding value and maternal breeding value for weaning weight was -1.36, 0.32 and 0.03 kg/year, respectively. As maternal genetic effect was considerably less important than direct genetic effect, selection for improved weaning weight of this Northeastern Thai indigenous cattle line can place more emphasis on the direct genetic effect.

Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities (다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화)

  • Choi, Im-Cho;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

Electrical Resistivity Survey in the Eon-Yang Fault Area, Southeastern Korean Peninsula (경상분지(慶尙盆地) 언양단층(彦陽斷層) 지역(地域)에 대(對)한 전기비저항(電氣比抵抗) 탐사연구(探査硏究))

  • Kim, In-Soo;Kim, Jong-Yeol
    • Economic and Environmental Geology
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 1983
  • Gyeongsang Basin in the southeastern part of the Korean peninsular is characterized by many fault systems. To decipher the geotectonical evolution of the Korean peninsular and marginal basins in her adjacent areas it is prerequisite to understand the spatial distribution pattern and mutual relationships of these fault systems. Because of difficulties in finding any criterion to recognize the faults in field, their extension and mutual relationships in ages are not very clear yet. As an attempt to find geophysical criteria to recognize the fault, geoelectrical resistivity survey was carried out in this study. With the Wenner configuration four resistivity soundings and twenty seven resistivity profilings were done. The electrode distance used was up to 50m. From the results of the resistivity soundings and boring data of earlier groundwater investigations the depth of alluvial and weathered zone was established to be at most 20m in the study area. In the resistivity profiling low resistivity anomaly zones are detected on every traverse, which are interpreted as caused by fractures, fault clays and mylonites in the fault zone. The width of the fault zone amounts to 0.3-1km. By correlating and connecting the negative anomaly zones from traverse to traverse one can determine the trend of th of the faultzone and therefore that of fault itself. The recognized fault trend in this way was $N15^{\circ}-20^{\circ}E$ and this coincides with the direction of the inferred fault line from earlier geological surface mapping. With the help of this characteristical negative anomaly the existance of another $N80^{\circ}W$ trending fault was estabished. This study has shown that geoelectrical resistivity survey can be applied successfully to the problem of tracing fault line insofar as a fault zone has been developed along fault line.

  • PDF

Variance component analysis of growth and production traits in Vanaraja male line chickens using animal model

  • Ullengala, Rajkumar;Prince, L. Leslie Leo;Paswan, Chandan;Haunshi, Santosh;Chatterjee, Rudranath
    • Animal Bioscience
    • /
    • v.34 no.4
    • /
    • pp.471-481
    • /
    • 2021
  • Objective: A comprehensive study was conducted to study the effects of partition of variance on accuracy of genetic parameters and genetic trends of economic traits in Vanaraja male line/project directorate-1 (PD-1) chicken. Methods: Variance component analysis utilizing restricted maximum likelihood animal model was carried out with five generations data to delineate the population status, direct additive, maternal genetic, permanent environmental effects, besides genetic trends and performance of economic traits in PD-1 chickens. Genetic trend was estimated by regression of the estimated average breeding values (BV) on generations. Results: The body weight (BW) and shank length (SL) varied significantly (p≤0.01) among the generations, hatches and sexes. The least squares mean of SL at six weeks, the primary trait was 77.44±0.05 mm. All the production traits, viz., BWs, age at sexual maturity, egg production (EP) and egg weight were significantly influenced by generation. Model four with additive, maternal permanent environmental and residual effects was the best model for juvenile growth traits, except for zero-day BW. The heritability estimates for BW and SL at six weeks (SL6) were 0.20±0.03 and 0.17±0.03, respectively. The BV of SL6 in the population increased linearly from 0.03 to 3.62 mm due to selection. Genetic trend was significant (p≤0.05) for SL6, BW6, and production traits. The average genetic gain of EP40 for each generation was significant (p≤0.05) with an average increase of 0.38 eggs per generation. The average inbreeding coefficient was 0.02 in PD-1 line. Conclusion: The population was in ideal condition with negligible inbreeding and the selection was quite effective with significant genetic gains in each generation for primary trait of selection. The animal model minimized the over-estimation of genetic parameters and improved the accuracy of the BV, thus enabling the breeder to select the suitable breeding strategy for genetic improvement.

A Study on the Characteristics of Change by Observation Area which changes as the observation time passes in Interior Space (실내공간에서 주시시간의 경과에 따른 구역별 주시특성에 관한 연구)

  • Kim, Jong-Ha;Ban, Young-Sun
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.84-91
    • /
    • 2012
  • The total data of observing interior space was divided into a few time frames for analysis. If we can understand the changing process of observation degree as the observation time passes, we will be able to analyse the characteristic and process of information obtainment in the case of space observation. For this purpose, the observation time was parted into 30 second units and the changing characteristic by time frame and observation area was analysed. The conclusion derived from this study is as the following: First, analysis of observation frequency and time on the basis of the average data of each subject showed that the observation time increased compared with the subject's frequency and the overall trend but that it was difficult for me to think there was a certain trend in the observation time of each subject. However, when I examined the time change by using the trend line which is a dynamic average line representing the observation time from the subjects as the trend element of time series, I could see the trend that the subject's observation time increased at a fixed rate as the frequency increased. Second, when I compared and analysed the average observation area at Area I set up by the time of 30 second unit and the observation area of Area I from the all data, I could see that the former had more degree of concentration at Area I. This analysis enabled me to get the degree of concentration on the observed area every time, and accordingly I could also see that when the data of intensive observation by time frame is analysed, the degree of concentration is dispersed for the subjects to observe very intensively or the area with overlapping observations each time frame can be seen as Area I out of the entire observation data. Third, when I analysed the observation characteristics by time frame at the 6 areas divided at 30 second unit at the rate of the number to the time of observation areas, I could see that as the observation time passed while the number of the observation areas defined as decreased the observation time increased, which means that when the area numbers decreases the area intensively observed by the subjects decreases as the time passes. In spit of that, the increase of time can be interpreted as more intensive observation of a specific area.

  • PDF

Development of Up-Down Turnout System of AGT for Reduction of Construction costs (건설비 절감을 위한 고무차륜 경량전철 상하식분기기 개발)

  • Cha, Kwon-Jung;Yoon, Il-Ro;Kim, Dong-Howal;Fukumoto, Yozo
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.745-752
    • /
    • 2011
  • Light Rail Vehicle(LRT) is "New Transit System" that has transportation capacity as well as physical size of vehicle is in-between bus and subway. The demand of LRT system is increasing rapidly; both domestically and internationally. Reason being is that it is more economical and eco-friendly compare to existing heavy rail vehicle. Especially, Busan Subway Line 4 K-AGT (Rubber-tired LRT) being the first of its kind to start revenue service in Korea, it is very much likely that application of its demand will continue to increase. Considering its trend, study to reduce implementation cost of LRT is being pursued in many different aspects; reducing construction cost is one that aspect. In this study, on-site application of 'Up-Down Turnout System' implementation research has been carried out which can replace existing 'Left-Right Turnout System'. When safety of its type gets verified, application of this system to line which intends to use K-AGT, Shin-Lim Line and Dong-Book Line, expects to save its construction cost. This thesis paper reports ongoing research of AGT 'Up-Down Turnout System' development and main component design factors, fundamental principle, performance test result.

  • PDF

Study on Very High-Rate Power Line Communications for Smart Grid (스마트그리드를 위한 초고속 전력선통신기술 연구)

  • Choi, Sung-Soo;Oh, Hui-Myoung;Kim, Young-Sun;Kim, Yong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1255-1260
    • /
    • 2011
  • In this paper, we study on the reliability of Very High-rate Power Line Communication (VH-PLC) for Smart Grid, so that the resultant data rate is over 400Mbps at a physical layer. Firstly, reviewing the research trend of the PLC, we discuss the required techniques for supporting the Smart Grid. Considering a pre-specification with the value of several parameters, we investigate a multi-carrier modulation technique to overcome limitations of higher rate transmission under power line channel environments. Then, we propose a system specification of the VH-PLC in the sense of enhancing two features. One is resolving the problem of the co-existence of the deployed high-speed PLC according to the published standardization of KS X 4600-1 in Korea. The other is getting better performance on the grid adopting the diverse element techniques, such as multi-carrier modulation, a subcarrier utilization mode, a variable rate LDPC (Low Density Parity Check) code, and a time and frequency diversity technique. Further, a simulation tool, composed of an Event-Driven simulator and a Time-Driven simulator, is developed for the purpose of verifying the system performance and continuously cross-checking the test bench signal of the proposed VH-PLC system.

New Technical Trend of Inspection and Test of Transmission Line (가공송전선로 점검 및 진단기술에 대한 해외기술동향)

  • Shin, Tai-Woo;Jang, Suk-Han;Kim, Mu-Soo;Min, Byeong-Wook;Choi, Jin-Sung;Yoon, Gen-Hwa;Gwon, Yeon-Han;Jung, Du-Ok;Bang, Hang-Kwon;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.315-317
    • /
    • 2008
  • Recently, a new construction of transmission line has been through quite hard situation due to demands for a new construction of transmission line have been saturated in south korea and also difficulties of purchasing the routes. In addition, the demands for electricity have been decreased in all of advanced countries of the world due to slowdown of the rate of economic growth. So they are trying to find a way to utilize a existing transmission line by extending the durable period. Therefore this is necessary to apply an applicable technology on domestic markets such as inspection, examination, maintenance of existing transmission lines by introducing advanced countries's example which shall be based on Japan's electric power companies.

  • PDF

A study Improvement Direction for Arc Interruption Equipment and On-line Monitoring System of Consumer Low Voltage Facilities (수용가 저압 전기설비의 원격 감시시스템 및 아크차단 장치 활성화 방안에 관한 연구)

  • Kim, Gi-Hyun;Park, Chee-Hyun;Lim, Young-Bai;Choi, Myeong-Il;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • Domestic and foreign follows the trend which is that safety checkup of electrical facilities is serviced by on-line system with joining information technology. This paper research improvement of what kind of system and law for market environment of electric power value added service. For improvement of market environment of electric power value added service, this paper researches improvement of on-line monitoring system and necessity of arc interruption and revision of arc related law.

Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator (공랭식 가스터빈 발전기의 운전중 부분방전 분석)

  • Lee, Eun-Chun;Kong, Tae-Sik;Kim, Jae-Chul;Kim, Hee-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly