• Title/Summary/Keyword: treatment systems

Search Result 2,947, Processing Time 0.037 seconds

Memtrane SEparation of Activated Sludge for Waste Water Treatment and Water Recycle

  • Miyano, O-Tadadki;Yohgi Inoue;Toyozo Hamada;Shuji Nakatsuka
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.39-39
    • /
    • 1999
  • Membrane separation technology has become a more attractive technology on waste water treatment and water recycle in recent years. On this application, membrane does not take main part of treatment, such as decomposition or handling of organic matter in the waste water, but it is very important supporting method in the total system. Activated sludge is most popular method as main part. In the system , membrane works as a separator to obtain clear water after biological treatment, by which the permeate could be released, recycled or applied to further additional treatment, instead of conventional sedimentation, coagulation and sand filtration. We would like to introduce our system cases for waste water treatment and water recycle, in which membrane separation technology works. In most of cases, membranes are applied to solid- liquid separation of activated sludge. Our experiences will be introduced as following items.

  • PDF

The removal of nitrogen & phoshorus for the swine wastewater by VSEP membrane system (진동막 분리장치를 이용한 축산폐수의 질소.인 제거에 관한 연구)

  • 지은상;김재우;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.31-36
    • /
    • 2000
  • Conventional membrane systems was difficults to treatment for the swine waste water. Technological advances in membrane filtration systems have created opportunity for the swine wastewater to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes it possible to filter effluent streams without the fouling problem exhibited by conventional membrane systems. Various kinds of waste water occurred to and swine wastewater experiment with "VSEP" set up conventional reverse osmosis membrane (ACM-4, ESPA, BW-30). The results were as followes : Treatment efficiency for the input COD(From $332mg/{\ell}$ to $4,968mg/{\ell}$) was 98%. Treatment efficiency for the input SS(From $140mg/{\ell}$ to $4,040mg/{\ell}$) was 100%(All together). Treatment efficiency for the input T-N(From $155mg/{\ell}$ to $934mg/{\ell}$) was 97%~99.8%. Treatment efficiency for the input T-P(From $28.6mg/{\ell}$ to $132mg/{\ell}$) was 99.7% and up. ESPA membrane excels three types of reverse osmosis membranes applied VSEP in removal efficiency.

  • PDF

Treatment Information based Risk Evaluation Method in Medical Information Systems (의료정보시스템에서 치료정보 기반 위험도 평가 방법론)

  • Choi, Donghee;Park, Seog
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.9
    • /
    • pp.441-448
    • /
    • 2016
  • RBAC(Role-Based Access Control), which is widely used in Medical Information Systems, is vulnerable to illegal access through abuse/misuse of permissions. In order to solve this problem, treatment based risk assessment of access requests is necessary. In this paper, we propose a risk evaluation method based on treatment information. We use network analysis to determine the correlation between treatment information and access objects. Risk evaluation can detect access that is unrelated to the treatment. It also provides indicators for information disclosure threats of insiders. We verify the validity using large amounts of data in real medical information systems.

Trends and Directions in the Development of Wastewater Reclamation and Reuse Technology for Alternative Water Resources (대체수자원 확보를 위한 하수 재이용 기술 동향과 발전방향)

  • Cho, Il Hyoung;Lee, Si Jin;Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.127-137
    • /
    • 2013
  • Reuse of wastewater will intensify in the coming decades due to water shortage, the change of climatic conditions, the need for industrial and agricultural use and the necessity of improving health and environmental conditions for the growing population. This paper considers (a) the status and trends of wastewater reuse and reclamation in the world, (b) case studies of wastewater reuse projects, (c) analysis of technology level, (d) forecast of global market, and (e) the future views and directions in development of wastewater reuse technologies. Based on the available documented literature, this paper provides a review assessment of the current status of the wastewater treatment processes including potential applications for reuse. Key challenges for both wastewater treatment and reuse are also discussed in the paper and include recommendations, e.g. cost, effluent water quality, energy use and technical solutions, for future developments.

Improvement of Transparent Electrodes Based on Carbon Nanotubes Via Corona Treatment on Substrate Surface (기판의 코로나 표면처리에 의한 탄소 나노튜브 투명전극의 물성 향상)

  • Han, Sang-Hoon;Kim, Bu-Jong;Park, Jin-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • In this study, we investigate the effects of corona-discharge pre-treatment on the properties of carbon nanotubes (CNTs) which are used as flexible transparent electrodes. The CNTs are deposited on PET (polyethylene terephthalate) substrates using a spray coating method. Prior to the deposition of CNTs, the PET substrates are corona-treated by varying the feeding directions of the PET substrate and the numbers of treatments. The variations in the surface morphologies and roughnesses of the PET substrates due to corona-treatment are characterized via atomic force microscopy (AFM). Dynamic contact angles (DCAs) of the corona-treated PET substrates are measured and analyzed as functions of the treatment conditions. Also, the sheet resistances and visible-range transmittances of the CNTs deposited on PET substrates are measured before and after bending test. The experimental results obtained in this study provide strong evidences that the adhesive forces between CNTs and PET substrates can be substantially enhanced by corona-discharge pretreatment.

Overcapacity of Water Treatment Plants in Korea (국내 정수장 과다시설용량 실태 분석)

  • Lee, Sangeun;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.57-67
    • /
    • 2009
  • Under the supply-oriented policy, efficiency and rationale have not been fully considered in planning of water supply facilities in Korea. As a case, this study shows that large-size systems are suffering from overcapacity problem of water treatment plants, and thus discusses what options should be applied to deal with inefficiency. Water demand of large-size systems has suddenly decreased for the last 10 years while water demand has been often assumed to increase at a regular rate in planning of plants according to excess capacity hypothesis. This inconsistency led to a serious overcapacity. In 2006, total excess capacity of nine large-size systems was more than 1.2 times as large as maximum daily demand of total customers in Seoul. However, their options are expected to stay ex post facto. To prepare the risk of overcapacity, and draw large benefits out of the plants, the authors and other professionals in Korea should further discuss the more adaptive method for prediction of water demand, and systems integration between a large-size system and adjoining systems.

Microbial population dynamics in constructed wetlands: Review of recent advancements for wastewater treatment

  • Rajan, Rajitha J.;Sudarsan, J.S.;Nithiyanantham, S.
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.181-190
    • /
    • 2019
  • Constructed wetlands are improvised man-made systems, designed for adopting the principle of natural wetlands for purifying wastewater - the elixir of life. They are used widely as a cost-effective and energy-efficient solution for treating greywater generated from different tertiary treatment sources. It provides an elaborate platform for research activities in an attempt to recycle earth's natural resources. Among the several organic impurities removal mechanisms existing in constructed wetland systems, the earth's active microbial population plays a vital role. This review deals with the recent advancements in constructed wetland systems from a microbiological perspective to (effect/ devise/ formulate) chemical and physical treatment for water impurities. It focuses on microbial diversity studies in constructed wetlands, influence of wetland media on microbial diversity and wetland performance, role of specific microbes in water reuse, removal of trace elements, some heavy metals and antibiotics in constructed wetlands. The impurities removal processes in constructed wetlands is achieved by combined interactive systems such as selected plant species, nature of substrate used for microbial diversity and several biogeochemical effected reaction cycles in wetland systems. Therefore, the correlation studies that have been conducted by earlier researchers in microbial diversity in wetlands are addressed herewith.

The Inpatients' Awareness of Co-operative Treatment System on Western Hospital and Oriental Hospital (양방과 한방병원의 협진체계에 대한 입원환자의 인식도)

  • Jin, Sam-Kon;Nam, Eun-Woo
    • Korea Journal of Hospital Management
    • /
    • v.3 no.1
    • /
    • pp.134-164
    • /
    • 1998
  • The purpose of this study is to provide the data for the co-operative treatment of western and oriental hospital. The studies were made a questionnaire to analyze inpatients' awareness on the systems of co-operative treatment and to observe the differences in medical service satisfaction between inpatients who had experienced the co-operative treatment of western and oriental hospital(Group 1) and those who did not (Group 2). The survey was conducted in February 1998, on 250 inpatients who were in a hospital which provided co-operative treatment of western and oriental medicine in Pusan. Korea. The results of this study were disclosed as follows: 54.2% of western hospital inpatients and 90.5% of oriental hospital inpatients suffered from diseases of the nervous system 88.9% of Group 1 and 72.2% of Group 2 believed that the co-operative treatment of western and oriental hospital was more effective in curing diseases of the nervous system. 33.5% or inpatiens in the western hospital and 87.4% of inpatients in the oriental hospital had received the co-operative treatment. In the case of the oriental hospital inpatients who had experienced western treatment, 36.8% received an examination radiologic, 30.7% received a laboratory test, 17.8% received physical therapy, and 14.1% received medication. Whereas, in case of the western hospital inpatients who had experienced oriental treatment, 71.8% received acupuncture, 23.9% received herbal medicine, and 2.8% received oriental medical tests. As to the opinion on the systems of co-operative treatment, 49.6% of Group 1 agreed that 'New medical institutions that adopt the merits of both western and oriental medicine are absolutely necessary.', and 48.9% of Group 1 agreed that 'Since there are strong points and weak points in both western and oriental medicine, partial and gradual introduction of the two systems would be better.' Whereas, 49.6% of Group 2 agreed that the partial and gradual introduction, and 35.7% of Group 2 agreed that the necessity of the new medical institutions. As to the motives for visiting the hospital, the most popular reason for all the inpatients was "others' advice". In the case of Group 1, however, the most popular reason was "the possibility of co-operative treatment". In regards to medical cost, the oriental hospital inpatients felt that their medical cost was too expensive. On the other hand, a smaller percentage of the western hospital inpatients felt that western hospital medical cost were too expensive. And between Group 1 and Group 2, a higher percentage of Group 1 felt that their medical cost was too expensive.

  • PDF

Volatile Fatty Acids Production During Anaerobic and Aerobic Animal Manure Bio-treatment

  • Hong, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.219-232
    • /
    • 2007
  • Odors from manures are a major problem for livestock production. The most significant odorous compounds in animal manure a.e volatile fatty acids(VFAs). This work reviews the VFAs from the anaerobic sequencing biofilm batch reactor(ASBBR), anaerobic sequencing batch reactor(ASBR), solid compost batch reactor(SCBR), and aerobic sequencing batch reactor(SBR) associated with the animal manure biological treatment. First, we describe and quantify VFAs from animal manure biological treatment and discuss biofiltration for odor control. Then we review certain fundamentals aspects about Anaerobic and aerobic SBR, composting of animal manure, manure compost biofilter for odorous VFAs control, SBR for nitrogen removal, and ASBR for animal wastewater treatment systems considered important for the resource recovery and air quality. Finally, we present an overview for the future needs and current experience of the biological systems engineering for animal manure management and odor control.

  • PDF

Study on the Network System between of the Outpatient and Central Treatment Department of Long Term Care Hospitals (요양병원 외래 및 중앙진료부의 의료영역 간 연결관계에 관한 연구)

  • Bae, Sunmi;Kim, Suktae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.7-17
    • /
    • 2016
  • Purpose: As our population ages and becomes an elderly society the number of elderly care hospitals is rapidly increasing. Because physical functions and spatial perception in the elderly decrease with age, these hospitals require more systematic and intelligent space designs. The design of these spaces are even more complex because they must accommodate medical programs to treat various different diseases and ailments and also because there are many first time patients and irregular short term patients that seek out outpatient treatment services. Also by analyzing the spatial configuration systems and systematic relationships between each of the functional spaces of the outpatient treatment service departments for hospitals specialized in care for the elderly by focusing on the hallway and corridor systems of these hospitals, the according characteristics and trends were examined. Methods: Based on preceding research, the types of hallway and corridor systems of these hospitals were categorized into five types, including gallery corridors, middle corridors, hall-type, mixed type and cyclic type corridors, and into six types according to function including by medical diagnosis, patient registration, examination, administration and convenience and shared common space to derive any interconnecting relationships between the corridor systems. Also by comprehensively examining the types and combined utilization of the corridor types and the integration and the intelligibility of the space syntax, any trends within the corridor system were derived. The elderly care hospitals examined in this research study were twelve hospitals that opened after the year 2000 in Korea with more that 150 sick beds with areas larger than $1000m^2$ and with all outpatient medical service related rooms located entirely on a single floor of the hospital. Results: The following results could be confirmed based on this research study. 1) The spaces where medical diagnosis and examination occurred were adjacent, and the movement lines for first time patients and re-visiting patients were taken into consideration by separating the treatment space. 2) This research study confirmed that the larger the size of the hospital was, there were more detailed categorizations of treatment services and that there was a tendency for treatment areas to be separated and independent from examination areas. 3) There was a tendency for integration and intelligibility to decrease the more complex and diverse the combination of hall types designed into the corridor systems of these hospitals was. cyclic type corridors dramatically decreased the intelligibility of the corridor systems of these hospitals. 4) The priority rank of these spaces were confirmed to be highest in the order of registration, diagnosis, examination, treatment, administration and shared common spaces. However it was confirmed for the local integration that the diagnosis scope had the highest priority rank. Implications: There were exceptional cases confirmed where the number of unit spaces did not have an absolute effect on integration and intelligibility. These results can be interpreted to mean that this can be overcome through efficient architectural planning.