• Title/Summary/Keyword: treatment efficiency

Search Result 5,229, Processing Time 0.034 seconds

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

Treatment Study of Textile Wastewater by Fenton's Oxidation (펜톤 산화반응에 의한 염색폐수처리 연구)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.20-25
    • /
    • 2000
  • The wastewater treatment for the purpose of water-recycling was performed using Fenton's & ozone's methods. These methods were used to increase the treatment efficiency of textile wastewater and to search for the optimal operating conditions. The optimal conditions by Fenton process were determined so that input amounts of $FeSO_4{\cdot}7H_2O$ and $H_2O_2$ were $7.2mM/{\;}{\ell}$ and $49.0m/{\;}{\ell}$ respectively, treatment by ozone process had 92% removal efficiency at ozone concentration of 9.73g/min and $130mM/{\;}{\ell}$ of $H_2O_2$.

  • PDF

Assessing the removal efficiency of Synedra sp. through analysis of field data from water treatment plants

  • Seo, Dae-Keun;Kim, Yeong-Kwan
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.141-149
    • /
    • 2020
  • Prechlorination could increase the removal efficiency of Synedra, but there was no significant effect of increasing the amount of chlorine added. However, a removal efficiency of greater than 80% was noted when ozone was injected at concentrations greater than 2 mg/L. Also, it was found that on addition of polyamine, a removal efficiency of 80% or more could be achieved. As a result of the analysis of field operation data from the water treatment plants G and B, it was found that at water treatment plant G, the filter run time decreased to 10 hours or less when only coagulant was injected, but the filter run time increased to around 40 hours when polyamine (3 mg/L) was also injected. The Synedra population in the raw water subsequently increased to 2,340 cells/mL, and the filter continued running for more than 20 hours. At water treatment plant B, the average Synedra removal efficiency was 56% when only coagulant was injected, and the filter run time decreased drastically with the increasing population of Synedra in the raw water. However, the removal efficiency of Synedra reached 79% when polyamine was injected together with the coagulant, 90% when ozone was also injected, and 95% when polyamine and ozone were injected together and the filter continued running for over 50 hours. The filter run time was maintained at 60 hours when a Synedra population of 6,890 cells/mL flowed into the Paldang water source, but the filter run time with Synedra at 1,960 cells/mL decreased rapidly from 65 hours to 35 hours when the ratio of the size of the individual Synedra reaching 250 ㎛ or more, increased from 38% to 94%. Therefore, the size of the Synedra is considered to be a factor that significantly influences filter clogging, as well as the size of the Synedra population.

Effects of Current Density and Electrolyte on COD Removal Efficiency in Dyeing Wastewater Treatment by using Electro-coagulation (전기 응집법을 이용한 염색 폐수의 처리에서 전류 밀도와 전해질의 COD 제거율에 대한 영향)

  • Jang, Seong-Ho;Kim, Go-Eun;Kang, Jeong-Hee;Ryu, Jae-Yong;Lee, Won-ki;Lee, Jae-Yong;Park, Jin-Sick
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.653-659
    • /
    • 2018
  • In the industrial wastewater that occupies a large proportion of river pollution, the wastewater generated in textile, leather, and plating industries is hardly decomposable. Though dyeing wastewater has generally been treated using chemical and biological methods, its characteristics cause treatment efficiencies such as chemical oxygen demand (COD) and suspended solids (SS) to be reduced only in the activated sludge method. Currently, advanced oxidation technology for the treatment of dyeing wastewater is being developed worldwide. Electro-coagulation is highly adapted to industrial wastewater treatment because it has a high removal efficiency and a short processing time regardless of the biodegradable nature of the contaminant. In this study, the effects of the current density and the electrolyte condition on the COD removal efficiency in dyeing wastewater treatment by using electro-coagulation were tested with an aluminum anode and a stainless steel cathode. The results are as follows: (1) When the current density was adjusted to $20A/m^2$, $40A/m^2$, and $60A/m^2$ under the condition without electrolyte, the COD removal efficiency at 60 min was 62.3%, 72.3%, and 81.0%, respectively. (2) The removal efficiency with NaCl addition was 7.9% higher on average than that with non-addition at all current densities. (3) The removal efficiency with $Na_2SO_4$ addition was 4.7% higher on average than that with non-addition at all current densities.

A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy (Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구)

  • Hwang, Yong Ha
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

Bisphenol-A Removal in Conventional Water Treatment Systems (정수처리공정에서 bisphenol-A의 제거에 관한 연구)

  • 김혜리;이윤진;박선구;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.59-64
    • /
    • 2004
  • This study was carried out to investigate influencing factors of bisphenol A(BPA) removal characteristic in conventional water treatment systems to be connected with coagulation, sedimentation, filtration and disinfection. The result are summarized as follows; In BPA removal, optimal doses of PAC, alum, ferric chloride were 7.5 mg Al/L, 10.0 mg AI/L, 15.0 mg Fek. PAC was most effective coagulant to remove BPA. In coagulation process, BPA removal efficiency were increased about 2% by adjusting pH of raw water as 6. At temperature rise 1$0^{\circ}C$, BPA removal efficiency were increased 0.94%. but BPA removal efficiency in sand filtration process were under 1 %ie, so that BPA was almost not removed. At free chlorine dose 1, 2 mg/L, the reaction rate constant k in the BPA removal have been calculated to be 0.397, 0.953 min$^{-1}$ . At free chlorine dose 1, 2 mg/1-, degradation reaction of BPA was completed during 10 min and BFA removal efficiencies were 97.66, 99.99% at this time.

Estimation of Contribution Ratio and Community Sewerage Treatment Efficiency by using Advanced Sewage Treatment in the Basin of Hongcheon-river (홍천강 유역의 하수고도처리를 적용한 마을하수처리 효율 및 기여율 평가)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3570-3576
    • /
    • 2013
  • This paper calculated advanced sewage treatment efficiency and reduction pollution loads to estimation contribution ratio of for community sewerage in Hongcheon-gun County. The A2/O and SBR methods showed overall high treatment efficiency of 95% and 94% respectively, and SS was 80%. On the other hand, T-N and T-P showed relatively low processing efficiency of 56% and 60% respectively, but it was observed that SS showed high 96% in the MBR method. Next, by the result of yearly water change analysis on water quality of Hongcheon River which is the discharge river of community sewerage, it was observed that water quality was greatly deteriorated by COD, T-N and T-P. However, installation and operation of community sewerage showed high pollution load reduction in general water quality item by more than 80%, and in T-N and T-P by 58% and 68% respectively. It is expected that community sewerage will greatly contribute in water quality improvement of Hongcheon River.

Evaluation of Treatment Efficiencies of Water Quality for 5 years in Constructed Wetland to Upper Region of Water Source (상수원 상류지역 인공습지의 5년간 수질 정화효율 평가)

  • Park, Jong Seok;Kim, Kang Seok;Kim, Yong Chan;Rhee, Kyoung Hoon
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.479-488
    • /
    • 2012
  • This study evaluates treatment efficiencies of pollutants in Boknae bio-park constructed wetlands surrounding Juam Lake for 5 years from January 2006 to December 2010, in order to treat non-point pollutants effectively. The analysis of monthly treatment efficiency of pollutants shows that the scope of BOD is -19.11~37.72%, and of COD is 30.14~27.38%, thus the monthly deviation COD is relatively higher than BOD, and the scope of SS is -54.07~64.82%. Moreover, the analysis of seasonal treatment efficiency of pollutants shows that the treatment efficiency of TN is higher than 36.8% on average for 5 years in the spring and winter, and of TP relatively lower than other pollutants, however, the seasons don't make much difference to the treatment efficiency of TP.

A Study on the Removal of Nitrogen and Phosphorus by Operation Mode for Livestock Wastewater Treatment Post-process Using SBR (축산폐수의 후처리공정으로서 SBR 적용시 운전인자에 따른 질소와 인의 제거특성에 관한 연구)

  • Choi, Gun-Youl;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.214-219
    • /
    • 2009
  • This study examined the removal efficiency of the nitrogen and phosphorus in order to compensate for the combined process of ATAD(Autothermal Thermophilic Aaerobic Digestion) and EGSB(Expended Granular Sludge Bed), which are treatment methods for livestock wastewater, by introducing SBR(Sequencing Batch Reactor) as post-treatment process. The analysis on the treatment efficiency of each operation mode showed that, in the case of T-N, the treatment efficiency were 67.1% and 74.2% for Run-1 and Run-2, respectively, and in the case of T-P, the values were 71.2 and 74.1, respectively, which are indicating that the treatment efficacy is higher in the condition of Run-1, in which the time period of Anoxic and Aerobic segments were increased. In addition, the result of analyzing removal characteristics of nitrogen and phosphorus by Influx load showed that removal efficiency of nitrogen was better in the case of high influx load than in the case of low influx load. Regardless of Influx load, phosphorus showed constant influx concentration, so that removal efficiency of phosphorus was influenced littler by Influx load than that of nitrogen. This study also fed methanol as an external carbon source and performed experiment to induce denitrification under anoxic condition by using nitrate among nitrogen compounds of SBR reactor, and the results showed that intermittent feeding was more effective in Nitrogen Removal than composite feeding.