• 제목/요약/키워드: treated temperature

검색결과 3,587건 처리시간 0.03초

붕산처리(硼酸處理) 합판(合板)의 열판건조(熱板乾燥) 및 동적(動的) 탄성율(彈性率)에 관(關)한 연구(硏究) (Studies on Press Drying and Dynamic Elastic Modulus of Plywood Treated with Boric Acid)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권3호
    • /
    • pp.56-67
    • /
    • 1987
  • Plywoods used for construction as a decorative interior material are inflammable and can make fire accidents, causing destruction of human life and property. Therefore, it is indeed required to make fire-retardant treated plywood. In this study, 3.7mm yellow meranti plywoods were soaked in 18% boric acid solutions and tap water by hot-cold bath for 1/2, 2/2, 4/2, 6/2 hours and redrying of treated plywoods was carried out by press drying at the platen temperature of 110, 130, 160, $180^{\circ}C$ and then it was conducted to investigate solution absorption, drying rates, dynamic young's modulus. specific gravity and fire-retardant factors such as burning point, flame spread length. flame exhausted time, back side carbonized area and weight loss by treating time, treating solutions and platen temperature. The results are as follows; 1. When plywood was impregnated with the hot bath temperature of $70^{\circ}C$ for 1. 2, 4, 6 hours and the cold bath temperature of $15^{\circ}C$ for 2 hours respectively, retentions of boric acid were 1.565, l.597, 1.643, 1.709kg/$(30cm)^3$ and all of them exceeded the minimum retention [1.125kg/$(30cm)^3$] even in the shortest treatment. 2. In hot-cold bath method for 1/2 hours, the drying rates of treated plywood remarkably increased with the extension of platen temperature of 110, 130, 160, $180^{\circ}C$ and the values of boric acid treated plywood were 5.900, 10.196, 45.42, 54.958m.c%/min and the values of water treated plywood were 6.014, 12.373, 46.520, 55.730m.c%/min and drying rates of water treated plywood were faster than those of boric acid treated plywood. 3. The values of boric acid treated plywoods in dynamic young's modulus were widely higher than those of water treated plywoods. And it can be observed that there were highly significant differences for treating time between dynamic young's modulus, and the values of boric acid plywoods increased with the extension of treating time but on the contrary water treated plywoods were decreased values with prolonged time 4. It was observed that there were highly significant differences for platen temperature between dynamic young's modulus. When the values of water treated plywoods in dyna nic young's modulus were abruptly decreased according to the rise of platen temperature. boric acid treated plywoods showed rather increased values at $160^{\circ}C$ of platen temperature. And in 2- way interactions, there were also highly significant for dynamic young's modulus between treating time x treating solutions and platen temperature x treating solutions. 5. Correlation coefficients of fire-retardant factors were shown in table 5. It could be recognized that there were close correlations between the treating solutions and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, but there was no correlation between fire-retardant factors and treating time and platen temperature. 6. From table 6, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carbonized area, weight loss between treating solutions. And in 2-way interactions, there were highly significant for burning point, flame spread length, weight loss between treating time $\times$ treating solutions.

  • PDF

액체암모니아 처리 면직물의 염색성 - 저온형과 고온형 반응성 염료에 의한 염색물의 색상강도 - (Dyeability of Cotton Fabrics Treated with Liquid Ammonia - Color strength of the dyeings with low-temperature and high-temperature reactive dyes -)

  • 전성기;이창수;임용진;김태경
    • 한국염색가공학회지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2004
  • The dyeability of cotton fabrics treated with liquid ammonia was investigated using low-temperature and high-temperature reactive dyes. From the results of dyeing rates of direct dye, the inversion time was shown at 600 hours at $40^{\circ}C$, and however it was shown at 10 minutes at $80^{\circ}C$. This was applied to reactive dyeings. In the low-temperature reactive dyes, the color strength of the fabrics treated with liquid ammonia was lower than that of mercerized fabrics. By contrast, in the high-temperature reactive dyes, the color strength of the fabrics treated with liquid ammonia was higher than that of mercerized one.

저융점 폴리에스터 자카드직물의 물성에 대한 열처리 효과 (Effect of Heat Treatment on the Physical Properties of LM PET Jacquard Fabrics)

  • 이선영;김정화;김의화;이정순;이승구
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.206-214
    • /
    • 2013
  • There has been an increasing demand for high performance and energy-saving of blind. In order to develop the eco-friendly blind textiles, heat treatment process has been utilized for LM(Low Melting) polyester fabrics and the changes of the physical properties of the treated fabrics were examined according to temperature of heat treatment. Morphology, surface reflectance, contact angle, luster, thermal property and mechanical property of heat treated LM polyester fabrics were investigated. As results, morphology analysis of thermal treated fabrics confirmed that degree of fusion of LM polyester yarns improved with increase of temperature. Surface reflectance of thermal treated fabrics decreased with increase of temperature. Luster and contact angle of a water droplet on thermal treated fabrics increased slightly with increase of temperature. The mechanical properties of the fabrics by KES-FB system were found to be temperature-dependent and especially, bending and shear properties among them were highly related to temperature.

열처리된 알루미늄 6061, 7075 합금의 온간 액압 성형 적용을 위한 온도 및 변형 속도 변화에 따른 변형 특성 연구 (A study on the deformation characteristic of heat-treated 6061,7075 aluminum alloy with changes of elevated temperature and strain rate for warm hydroforming)

  • 이혜경;문영훈;손성만;이문용;서동우;이상용
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.23-26
    • /
    • 2004
  • The deformation behaviors of fully annealed or T6-treated 6061 and 7075 aluminum tubes are investigated at elevated temperature using uniaxial tensile test. Fully annealed 6061 and 7075 tube, and T6-treated 7075 tube do not show sharp local necking with an elongation of $50\%$ at tensile temperature of $300^{\circ}C$, accordingly, it is expected that warm hydroforming process can be applied. The increase of tensile temperature does not significantly affect the total elongation of T6-treated 6061 tube.

  • PDF

The Physiological Response on Wear Comfort of Polyethylene Terephthalate Irradiated by Ultra-violet

  • Choi, Hae-Young;Lee, Jung-Soon
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.446-449
    • /
    • 2006
  • The purpose of this study was to evaluate the comfort of PET clothing treated by UV. The physiological responses of the human body were investigated. Mean skin temperature and physiological signals such as Electroencephalogram (EEG), and heart rate (Electrocardiogram, (ECG)) were examined for 20 minutes during stable wearing conditions. Mean skin temperature was measured every two seconds using Ramanathan's method. Physiological responses were measured using Biopac MP100 series and analyzed using the software, Acqknowledge 3.5.2. Psychological effects were analyzed every five minutes. Comfort of untreated PET clothing decreased with the passage of time. Compared with PET clothing untreated, treated for 30 minutes, and treated for 90 minutes, the analysis of EEG showed that PET clothing treated for 90 minutes was the most comfortable after 20 minutes. In addition, the interval of the heart rate shown on the ECG was the highest in PET clothing treated for 90 minutes. Skin temperature was the lowest in PET treated for 90 minutes. We thus conclude that suitable UV irradiation would improve comfort.

질산칼슘 처리농도에 따른 수축견사의 이화학적 특성 (Physical and Chemical Properties of Silk Fiber Treated with Calcium Nitrate)

  • 이광길;이용우
    • 한국잠사곤충학회지
    • /
    • 제40권1호
    • /
    • pp.70-77
    • /
    • 1998
  • This study was carried out in order to find out the relationship between physical and chemical properties of silk fiber treated by concentrated calcium nitrate solution. The tensile, thermal and dynamic mechanical properties are also examined on Ca(NO3)2 treated silk fibers. The tensile properties of silk fibers treated by calcium nitrate changed with a concentration. The thermal behavior were also affected by the concentration of calcium nitrate. The degradation temperature (endotherms) and glass transition temperature shifted to lower temperature as the treated concentration increased. It is thought that the physical properties are strongly related to the structure and morphology of Ca(NO3)2 treated silk fibers. As a result, these give property changes with a concentration dependence.

  • PDF

공단폐수슬러지의 토양중 화학적 특성 변화 (Changes of Chemical Characteristics of the Industrial Wastewater Sludge in Soil)

  • 이흥재;조주식;허종수
    • 한국환경과학회지
    • /
    • 제5권4호
    • /
    • pp.525-533
    • /
    • 1996
  • Chemical characteristics of the industrial wastewater sludge, degradation of the sludge in soil and CO2 generation and changes of nitrogen in soil treated with the sludge were investigated. The results obtained were summarized as follows: 1. Degradation rate of the sludge in soil was 26% at natural temperature, and 33% at incubation temperature at 12 weeks after treatment. 2. T-C, T-N and the C/N ratio of sludge in soil was 16.0%, 0.63% and 26, respectively, at natural temperature, and 15.0%, 0, 65% and 23, respectively, at incubation temperature at 12 weeks after treatment. 3, Camulative CO2 generation in soil treated with l%, 3% and 5% of sludge was 284, 440 and 512 mg/100 g, respectively, at natural temperature, and 440, 558 g and 654 mg/100g, respectively, at incubation temperature at 12 weeks after treatment. 4, Changes of :norganic nitrogen in soil treated with l%, 3% and 5% of sludge were 7.8, 12.8 and 16.3 mg/100g, respectively, at incubation temperature at 12 weeks after treatment. Mineralization ratio of organic nitrogen in soil treated with 1%, 3% and 5% of sludge was 10.7%, 13.6% and 15.2%, respectively, at incubation temperature at 12 weeks after treatment. 5. Chanties of pH in soil treated with 1%, 3% and 5% of Industrial wastewater sludge were in the range of 6.7~7, 5 at natural temperature, and 6.1~7.9 at incubation temperature at 12 weeks after treatment.

  • PDF

초음파 신호의 패턴 인식에 의한 금속의 열처리 온도 분류 (Temperature Classification of Heat-treated Metals using Pattern Recognition of Ultrasonic Signal)

  • 임내묵;신동환;김덕영;김성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1544-1553
    • /
    • 1999
  • Recently, ultrasonic testing techniques have been widely used in the evaluation of the quality of metal. In this experiment, six heat-treated temperature of specimen have been considered : 0, 1200, 1250, 1300, 1350 and 1387$^{\circ}C$. As heat-treated temperature increases, the grain size of stainless steel also increases and then, eventually make it destroy. In this paper, a pattern recognition method is proposed to identify the heat-treated temperature of metals by evidence accumulation based on artificial intelligence with multiple feature parameters; difference absolute mean value(DAMV), variance(VAR), mean frequency(MEANF), auto regressive model coefficient(ARC), linear cepstrum coefficient(LCC) and adaptive cepstrum vector(ACV). The grain signal pattern recognition is carried out through the evidence accumulation procedure using the distances measured with reference parameters. Especially ACV is superior to the other parameters. The results (96% successful pattern classification) are presented to support the feasibility of the suggested approach for ultrasonic grain signal pattern recognition.

  • PDF

ATY 사가공에 의한 Fluffy Spun-like Yarn의 물성 (1) (The Mechanical Properties of Fluffy Spun-like Yarn by ATY Textured (1))

  • 박명수
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.223-231
    • /
    • 2013
  • This research has a main focus on providing fundamental data for on-the-spot industrial fields by comparing and contrasting physical properties of fluffy spun-like material. The fluffy spun-like yarn is developed as fluffy yarn similar to natural spun-like yarn by treating polyester(FDY and + type shaped DTY) with ATY machine. In this experiment, using ATY machine for raw material texturing, we produced two fluffy yarns: (i) + type shaped(50d/36f, DTY) as core yarn and 100d/192f FDY as effect yarn[ATY(D)], (ii) FDY(75/36) as core yarn and 100d/192f FDY [ATY(F)] as effect yarn. After producing thous yarns, we twisted them with 500T/M, 700T/M, 1000T/M, respectively. produced yarns through this process were used as the samples for this experiment. Even though the shrinkage of fluffy yarn ATY(F) and ATY(D) becomes high as treated temperature rises and treated time lengthens, it is more affected by treated temperature then by treated time. In this experiment, produced fluffy yarn[ATY(D)] shows a little high values for temperature, but almost same values for higher temperatures. When we compare ATY(F) with ATY(D) fluffy yarn shows more natural fluffy yarn surface structure like natural cotton. The shrinkage of 700T/M twisted ATY(D) fluffy yarn show about 11% under treated temperature $180^{\circ}C$ and treated time 30min, and about 7% under $120^{\circ}C$ and 30min, respectively. But the shrinkage of 1000T/M fluffy yarn shoes about 9% and 6% under same conditions. Regarding treated time, tenacity and initial modulus of ATY(D) fluffy yarn rise high until 30min, but do not show much increase above 30min. Regarding treated temperature, tenacity and initial modulus of it rise high aboyer $140^{\circ}C$.

STUDIES ON THE HIGH TEMPERATURE PROPERTIES OF DUPLEX-TREATED AISI H13 STEEL

  • Chung, J.W.;Lee, S.Y.;Kim, C.W.;Kim, S.S.;Han, J.G.;Lee, S.Y.
    • 한국표면공학회지
    • /
    • 제29권6호
    • /
    • pp.634-639
    • /
    • 1996
  • In oder to improve the wear resistance as well as oxidation resistance at high temperature a AISI H13 steel was treated by a duplex process of calorizing followed by plasma nitriding. The surface properties of the duplex-treated AISI H13 steel was characterized and compared with those treated by single surface process of calorizing and plasma nitriding, in terms of microstruture, microhardness, wear resistance at $500^{\circ}C$, and the oxidation behaviours at $700^{\circ}C$, Duplex process on H13 steel had created duplex layer of approximately $190\mu\textrm{m}$ on the surface, and surface microhardness was measured to be above 1450Hv(0.1Kgf). There was considerable improvement of the high temperature wear resistance at $500^{\circ}C$ in the duplex-treated steel when both wear volume and weight change due to oxidation were considered. In addition the duplex-treated steel showed an improved high temperature oxidation resistance than the plasma nitrided steel at $700^{\circ}C$.

  • PDF