Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

Variation of dissolved organic matter in 2nd treated sewage water by Al(III) coagulant (Al(III) 응집제에 의한 하수처리수 중의 유기물 성상 변화)

  • Kim, Jungsun;Han, Seungwoo;Kim, Suhyun;Kang, Limseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.233-240
    • /
    • 2016
  • Control degree and property changes of dissolved organic matter (DOM) were conducted by coagulation of chemical treatment for 2 sewage treatment plants with different technical methods. As the result, SUVA value of the second treated water (supernatant of the second settling pond after biological treatment) was increased and DOC was reduced in comparison with supplied raw water. And, SUVA value and DOC were reduced by coagulation after coagulation treatment of the second treated water. Properties of dissolved organic matter for 2 sewage treatment plants's DOC were divided. As the result, there was lots of hydrophilic component with hydrophilicity in case of plant A. In case of the second treated water, Plant A showed fulvic acid with little molecular weight was reduced among the hydrophobic component with hydrophobicity, but numic acide with lots of molecular weight was increased. However, in case of plant B, both fulvic acid with little molecular weight and humic acid with lots of molecular weight were increased among the hydrophobic components with hydrophilicity. Before the operation of phosphorus facility, properties of dissolved organic matter after biodegradation with effluent water showed hydrophilic components were reduced and hydrophobic components were increased. However, after coagulation treatment of the second treated water, hydrophilic components and hydrophobic components were outstandingly decreased or increased. During the biodegradation after coagulation treatment, hydrophilic components were significantly decreased and hydrophobic components were increased.

Evaluation of Drying Performances by Hydrothermal Reaction of Sewage Sludge and Food wastes (하수슬러지 및 음식물류폐기물의 수열반응에 의한 건조 효율 평가)

  • Shin, Myung-Seop;Lee, Hyung-Don;Jeon, Yong-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.47-55
    • /
    • 2017
  • The technology for hydrothermal reaction of organic waste is one of the promising process to improve energy efficiency of biomass waste recycling system since moisture contents of treated biomass could be reduced at 40% or less than by dehydration processes. For these reasons, many parts of the world are interested in hydrothermal reaction of organic waste. In this paper, drying performances were evaluated with and without hydrothermal reaction of organic wastes which are sewage sludge and food wastes. For the hydrothermal reaction, organic wastes were treated at $200^{\circ}C$ for 1hr. Drying time of treated organic waste by hydrothermal reaction was reduced. In case of food waste drying at $100^{\circ}C$, drying time of treated wasted was reduced more 52.9% than non-treated. Hence, drying performances of sewage sludge and food wastes should be improved by hydrothermal reaction. Drying rates of treated wastes were considerably increased at preheat period of drying characteristic curve as followings; at $80^{\circ}C$ sludge as 148%, $100^{\circ}C$ sewage sludge as 151%, $80^{\circ}C$ food waste as 209%, $100^{\circ}C$ food waste as 366%. It means the surface area of treated wastes could be increased with destruction of cell membrane by hydrothermal reaction. However, the designer and operator of drying process should be careful, since enhanced drying rate cause the extension the decreasing drying period.

Efficient Sewage Treatment with Less sludge Production by Used Briquets (연탄재를 이용한 슬러지 저감 하수처리 연구)

  • Jeong, Doo-Young;Jeong, Myung-Hee;Song, Dae-Yong;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • We have investigated the efficacy and efficiency of the used briquets for the sewage treatment in this study. The effluent of wastewater treated by Used Briquets Process (UBP) showed very low values of $BOD_5$, CODcr, and SS (1.1 mg/L, 9.5 mg/L, and 3.8mg/L, respectively), which corresponded to 99%, 92.7%, and 96.3% of removal efficiency to the raw wastewater. The number of total bacteria and E. coli in the effluent water treated by UBP was found to be 9 and 1.2 cfu/ml, respectively, showing the remarkable decrease in number, when compared to that of other sewage treatment plants. In the long period of experiment over 1 year, UBP has also shown the high removal efficiency with less sludge production, and low seasonal fluctuation of the values. This UBP is very environmentally-friendly process in the aspects of recycling used briquets and reducing the sludge production. We think that this process will be useful for both the small-scale sewage treatment and reuse of the effluent water.

  • PDF

Cost Analysis of Ocean Outfall and Tertiary Treatment Processes in Suyong Sewage Treatment Plant (수영 하수처리장 방류수의 해중 방류법과 3차 처리시설 설치시 비용 비교 분석)

  • 박해식;조은일;박청길
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.115-123
    • /
    • 1999
  • Sewage has been almost treated by secondary treatment process. Secondary-treated effluent of sewage treatment plant caused the pollution of nearby beach. Nitrogen(N) and Phosphorus(P) in effluent water have caused many problems on estuary, such as red tide, eutrophication and aquatic toxicity. Therefore, the effective nitrogen and phosphorus removal from sewage treatment plants is necessary to prevent those pollution problems. However, little sewage treatment plant in Korea is effectively being operated for the removal of the nutrients. This study is analyzed for the effectiveness of cost when tertiary treatment process and Ocean Outfall are applied for the water quality of Suyong Bay After secondary treatment process, the effluent was discharged from the seabed in the depth of 32m of 4000m offshore. Pollutant concentration is decreased as much as the 180 times after the result of initial dilution, so that environmental protection requirement of Suyong Bay can satisfied. This Ocean Outfall process can save the 2.6~3.5 times as much as the cost of construction and operation for tertiary treatment process running over a 20 year.

  • PDF

Analysis of Water Quality caused by Improvement of Sewage Treatment Plant in Masan Bay (하수처리장 개선이 마산만 수질에 미치는 영향분석)

  • Oh Hyun-Taik;Goo Jun-Ho;Park Sung-Eun;Choi Yun-Sun;Jung Rae-Hong;Choi Woo-Jeung;Lee Won-Chan;Park Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.777-783
    • /
    • 2005
  • For the sustainable management of marine ecosystem in Masan Bay, we have to assess the carrying capacity and standard of target water quality. In this research, we assume that all pollutants loads are treated in Dukdong sewage treatment plant, then we simulate the physical-biological model for prediction water quality for the achievement of standard water quality. In 2001 year, for the achievement of COD 2.5 mg/L, we need to reduce COD $90\%$, nitrogen $30\%$, phosphate $90\%$ than that of the present value, According to these results, the water quality of sewage treatment plant is required to treat COD 13.5 mg/L, nitrogen 33.3 mg/L, phosphate 6,0 mg/L. If the sewage treatment plant will be expanded much larger in 2011, it will need to be treated in COD 6.6 mg/L, nitrogen 2.5 mg/L, phosphate 5 mg/L for the achievement of water quality standard in COD 2.5 mg/L.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

하수슬러지의 토양개량재 적용시 유기인계 농약의 흡착능력에 관한 연구

  • 임은진;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.125-130
    • /
    • 2004
  • This study has been assessed the influence of applying sewage sludge to soil amendments on the sorption properties, and leaching potential of three commonly used organophosphorus pesticides, Diazinon, Fenitrothion, and Chlorpyrifos. A sandy soil with a low content of organic carbon was treated with sewage sludge with a ratio sandy soil : sludge ratio of 30:1. The sorption was determined with the batch equilibrium technique. The sorption isotherms could be described by Freundlich equation. The Freundlich constant, K value which measures sorption capacity, were 3.97, 9.94, 22.48 for Diazinon, Fenitrothion, Chlorpyrifos in non-amended soil. But in amended soil, K value was 12.58, 28.47, and 61.21 for Diazinon, Fenitrothion, and Chlorpyrifos. The overall effect of sewage sludge addition to soil was to increase pesticides adsorption, due to the high sorption capacity of the organic matter. The effect of sludge on tile leaching of pesticides in the soil was studied using packed soil columns. Total recoveries of pesticides in soil and leachate with leaching in soil column, were in the range of about 73~84%, was reduced with the passage of time. Diazinon moved more rapidly than Chlorpyrifos in the unamended soil due to greater sorption and lower water solubility of Chlorpyrifos. Total amounts of pesticides leached from the sewage sludge amended soils were significantly reduced when compared with unamended soils. This reduction may be mainly due to and increase in sorption in amended soils, as a consequence of the increase in the organic matter content.

  • PDF

Optimum Operation of a PVDF-type Hollow Fiber Membrane Bioreactor for Continuous Sewage Treatment

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1315-1322
    • /
    • 2010
  • A membrane bioreactor (MBR) was designed using polyvinylidene fluoride(PVDF)-type hollow fiber membrane modules with a treatment capacity of 10 ton/day. A pilot plant was installed in a sewage treatment plant and was operated with an intermittent aeration method which avoids any concentration gradient of suspended solids (SS) in the MBR. For continuous operation, the pilot plant was first tested with influent (mixed liquor suspended solid:MLSS of 1000-2000 mg/L) of aeration tanks in the sewage treatment plant. The MBR was pre-treated with washing water, 10% ethanol solution, 5% NaOCl solution and finally washing water, one after another. To demonstrate the effect of the MBR on sewage treatment, compared with conventional activated sludge processes, we investigated the relationships among permeate amount (LMH), change in operation conditions, influent MLSS level and sludge production. It was found that the optimum aeration rate and suction pressure were $0.3\;m^3$/min and 30~31 cmHg, respectively. Under stable conditions in aeration, suction pressure, influent flow rate and drainage, the SS removal efficiency was more than 99.99% even when the MLSS loading rate changes. Compared with conventional activated sludge processes, the MBR was more effective in cost reduction by 27% based on permeate amount and by 51.5% on sludge production.