• Title/Summary/Keyword: treated sewage

Search Result 244, Processing Time 0.031 seconds

Effects of sewage sludge Application on the Growth of Lettuce (Lactuca sativa L.) (상추의 생육에 대한 도시하수 슬러지의 영향)

  • Lee, Sang-Uk;Yoon, Wha-Mo;Oh, In-Hye
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • This study was aimed to observe the effects of municipal sewage sludge as nutrients on the growth of Lettuce. The effects of heavy metal components of the sludge were also observed. Municipal sewage sludge from Taejon City were treated to the soil of PaiChai University Farm in order to make gradient of nitrogen concentration in soil among 6 experimental groups. Results are as follows ;The longest leaves and roots were produced in control pot, in which urea was supplied as nitrogen source to the soil. Any other sludge-treated groups produced shorter leaves and roots than control group, but the more sewage sludge treated the longer leaves and heavier vegetables were observed. No differences were observed among from 6 experimental groups in the view of N, K, Ca and Mg contents. But P contents in leaves from 6 groups varied. Zn content of Lettuce when was 65.8 mg/kg when it grew with sludge 200%. The groups treated with sludge 200% produced the vegetables of highest Zn contents. Accumulation of Zn, Mn and Cd was more heavier in Lettuce than in Altari radish. Accumulation of Zn, Mn, Cu and Cd in lettuce was not heavier than natural contents of those in market vegetables.

  • PDF

Economic Evaluation on Energy System Using Treated Sewage Water (하수처리수 이용 열원시스템의 경제성 평가)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.3
    • /
    • pp.16-22
    • /
    • 2017
  • It has become important for unutilized energy to be used for air conditioning of building. Economic evaluation on energy system by using treated sewage water as heat source, which is one of unutilized energy, was performed. The floor area of the subject building and the distance between heat source equipment and sewage treatment plant was assumed $30,000m^2$ and 200m. Absorption chiller-heater system was used for comparing to the energy efficient system, and payback period method was applied to carry out economic evaluation. Although the operating cost of this system is reduced compared to general heat source system, the ratio is not meaningful compared to the initial investment cost increase, and payback period was calculated to be about 36.1 years. However, when calculated based on the 2014 rate of electricity and city gas, it will be greatly reduced to 3.1 years. International commodity prices are constantly changing, and therefore national policy on the spread of unutilized energy should be maintained.

Effect of Reclaimed Sewage Irrigation on Paddy Rice Culture and Soil Characteristics (오수처리수의 관개가 벼 생육 및 토양 특성에 미치는 효과)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.3
    • /
    • pp.66-75
    • /
    • 2000
  • Effect of reclaimed sewage on the paddy rice culture was examined by field experiment for two consecutive years. The domestic sewage was treated by the constructed wetland and the effluent of the treatment wetland was used for irrigation water. The reclaimed sewage was diluted before irrigation in the first year and it was used without dilution in the second year experiment. Growth components and yields were compared against the control plot where conventional method was applied. And also soil characteristics of the plots before and after reclaimed sewage irrigation were analyzed Generally addition of the reclaimed sewage irrigation didn't affect paddy rice culture adversely and even enhancement was observed. Fertilization was thought to be important factor for rice culture rather than irrigation water quality. Conventional fertilization and reclaimed sewage irrigation which contained high nutrient concentration resulted in better growth and more yield. Unlike widespread concern lodging did not happen even in the case of irrigation with average 90mg/L of T-N and conventional fertilization. Soil characteristics changed after irrigation and significant EC increasing was observed for the reclaimed sewage irrigation plots. From soil analyses salt accumulation could be a more potential problem than nutrients like nitrogen and phosphorus in the use of reclaimed sewage irrigation. Overall reclaimed sewage irrigation was thought to be one of practical alternatives for the ultimate disposal of sewage in rural area.

  • PDF

Development of Constructed Wetland using Sand and Oyster shell for Sewage Treatment (모래와 굴패각을 이용한 인공습지 오수처리장치 개발)

  • Park, Hyun-Geoun;Lee, Chun-Sik;Lee, Hong-Jae;Seo, Dong-Cheol;Heo, Jong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.437-446
    • /
    • 2004
  • To develop sewage treatment apparatus by natural purification method, the sewage treatment plant that consisted of aerobic and anaerobic plot was constructed. And then, the effects of treatment conditions on the removal of pollutants in the relation to sewage loading, sewage injection method and season according to the pebble kind. Removal rate of BOD and COD according to the sewage loading in effluent were over 95 and 77%, respectively. Removal rate of nitrogen in treated water by aerobic plot and effluent using sand were about 22~40 and 49~75%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% as filter media in comparison with using sand were about 7~25 and 16~23%, respectively. Removal rate of phosphorus in treated water by aerobic plot and effluent using sand as filter media were about 30~36 and 52~56%, respectively. Those of effluent using sand 75%+ oyster shell 25% and sand 50%+ oyster shell 50% in comparison with using sand as filter media were about 11~40 and 12~45%, respectively. Removal efficiency of BOD and COD according to the intermittent injection method of sewage were slightly decreased, but those of nitrogen and phosphorus were little varied in comparison with continuous injection method. Removal efficiency of BOD and COD in winter in comparison with the others were little varied, but those of nitrogen and phosphorus slightly decreased.

Implementations of Geographic Information Systems on Sewage Management for Water Resources Protection

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Chou, Wen-Shang;Huang, Hsiu-Lan
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1188-1190
    • /
    • 2003
  • Taipei Watershed Management Bureau (WRATB) is a government agency entitled for water resources protection at two major watersheds in order to provide drinking water for about four millions population in Taipei on a sustainable basis. At WRATB, there are two major public sewage treatment facilities which can convert sewage in each watershed into an acceptable state before they were discharged into rivers. More than 82% of household wastewater have been collected and treated by the two public sewage systems. However, households at remote area still need more effective sewage management prescriptions. The objective of this paper is to implement geographic information systems in order to provide more effective approaches that sewage management can be easier and cost effective. ArcIMS was implemented for Internet browsing and map server of those sewage facilities on personal computers, laptop computers. In the open field, ArcPAD was implemented with personal digital assistant (PDA) such that compact flash type's global positioning systems (GPS) and digital camera can be utilized with PDA. All sewage facilities digital files were convert into ArcMap format files. MapObjects and visual BASIC were used to create sewage application modules to meet every single technician personal flavor. ASP.NET was implemented for Internet database manipulations of all sewage databases. Mobile GIS was the key component of GIS applications in the open field for sewage management on a basis of house by house. Houses at remote area, which can not cover by the two public sewage systems, were managed by PDA and laptop computers with GPS and digital camera. Sewage management at Taipei Watershed Management Bureau is easier both in the open field and in the office. Integration of GPS, GIS, and PDA makes sewage management in the open field much easier. ArcIMS, MapObjects, ASP.NET and visual BASIC make sewage management can be done in the office and over Internet.

  • PDF

Sewage and Tissue Wastewater Treatment Using Quartz Porphyry and Natural Zeolite (맥반석과 천연제올라이트를 이용한 도시하수와 화장지폐수처리)

  • Lee, Chang Hyun;Kim, Jae Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.517-522
    • /
    • 2012
  • In this study, not only making an effort to find a solution for sewage and wastewater treatment, but also demonstrating a feasibility of wastewater disposal process which is treated with the cohesion and adsorption mechanism of sewage and wastewater using quartz porphyry and zeolite, which is a domestic natural resource. By using a jar test, we evaluated removal efficiency of $COD_{Cr}$ after reation. According to the result of experiment, when we injected 400~1,200 g/L of quartz porphyry and zeolite into a sewage as a coagulant, there was no difference of the rejection rates of $COD_{Cr}$, however, when quartz porphyry and zeolite, which were sintered at $600^{\circ}C$, were treated into urban sewage, removal efficiency of $COD_{Cr}$ had increased by about 15%, 3% respectively. In addition, we applied into a cosmetic tissue wastewater by using mixture of quartz porphyry and natural zeolite in order to analyze the applicability of other wastewater as well as Municipal Sewage.

Evaluation of Anaerobic Fermentation and Nitrate Removal Efficiency of Sewage Sludge Pre-treated with Electrolysis (전기분해 전처리 슬러지의 혐기성 소화 및 질산염 제거효율 평가)

  • Kim, Jaehyung;Jeon, Hyeyeon;Pak, Daewonk
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • This study was performed with electrolysis treatment method for improving anaerobic digestion gas production efficiency in a sewage sludge, thereby confirmed in anaerobic digestion production and denitrification effect. As a result, solubilization was increased by increasing treatment time of electrolysis and current density, also showed to be 9.02% with 10 mA/cm2 of current density in 4 mm electrode distance. Based on the results of BMP test used the above experiment, methane production was 0.49 L CH4/g VS, and increased by 88.4% compared with control groups. As for the results of denitrification using the sewage sludge treated with the same conditions, denitrification rate appeared $19.2mg\;NO_3{^{-}}N/g\;MLVSS{\cdot}hr$, and through the sewage sludge treated with electrolysis, it can be applied to anaerobic digestion and denitrification process by increasing biodegradation.

Conversion of CODMn into TOC and Refractory Organic Matter Concentrations for Treated Sewage using Regression Equations (회귀식을 사용한 하수처리장 방류수 CODMn 농도의 총 유기탄소 및 난분해성 물질 농도 전환)

  • Lee, Tae-Hwan;Lee, Bomi;Hur, Jin;Jung, Myung-Sook;Kang, Tae-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.969-975
    • /
    • 2010
  • Estimating the organic matter loadings from individual treated sewage has become important for establishment of effective management strategies to control refractory organic matter (R-OM) in watersheds. For this study, regression equations were constructed using treated sewage data to convert the chemical oxygen demand (COD) concentrations, which are mostly available from open database, into total organic carbon (TOC) and R-OM concentrations. Effluent samples were collected from five major sewage treatment plants (STPs) located upstream of the lake Paldang. Variations in the OM concentrations were not associated with either the location of the STP or the sampling season. The effluent investigated were characterized by higher ratio of R-OM with respect to biodegradable organic matter (B-OM) and higher presence of dissolved organic matters (DOM) versus particulate organic matter (POM). Compared to $COD_{Mn}$, $COD_{Cr}$ exhibited higher oxidation efficiencies and greater variations in the concentrations. The concentrations of $COD_{Mn}$ were positively correlated with dissolved organic carbon (DOC), total organic carbon (TOC), and R-OM concentrations. There was nearly no seasonal and annual variation in the regression equations between $COD_{Mn}$ and TOC or R-OM concentrations. The constructed regression equations for TOC and R-OM were $0.650({\pm}0.071){\times}COD_{Mn}+1.426({\pm}0.575)$ and $0.340({\pm}0.083){\times}COD_{Mn}+2.054({\pm}0.670)$, respectively. The established equations are expected to contribute to estimating OM loadings from the STPs into the lake Paldang and also to compensating for the deficiency of the data for effluent OM concentrations in STP.

Feasibility study on district heating Magok area by sewage water heat source (마곡지구 하수열에너지이용 타당성 검토)

  • Lee, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.357-362
    • /
    • 2009
  • As a unutilized energy, treated sewage water locates widespread near urban areas. From the previous survey, the sewage water is reported to hold energy potential up to 36,000 Tcal/year, which was 2.1% of the total domestic energy consumption and 9.7% of the energy usage in the household and business sector in 2006. Temperature of the sewage water differs locally, but its range is observed in a range of $20{\sim}25^{\circ}C$ in summer and $8{\sim}13^{\circ}C$ in winter. Since the temperature range of the sewage water has a better seasonal distribution about $5{\sim}10^{\circ}C$ compared to ambient air, it is a promising heat sink for summer or heat source for winter. The sewage water is also a high quality heat source from its abundant quantity and uniform temperature. Considering the ambient temperature of Korea is very low in winter, a heat pump system using the sewage water can be an alternative to prevent problems of capacity deficiency and frost formation.

  • PDF

Effect of slag on stabilization of sewage sludge and organic soil

  • Kaya, Zulkuf
    • Geomechanics and Engineering
    • /
    • v.10 no.5
    • /
    • pp.689-707
    • /
    • 2016
  • Soil stabilization is one of the useful method of ground improvement for soil with low bearing capacity and high settlement and unrequired swelling potential. Generally, the stabilization is carried out by adding some solid materials. The main objective of this research was to investigate the feasibility of stabilization of organic soils and sewage sludge to obtain low cost alternative embankment material by the addition of two different slags. Slags were used as a replacement for weak soil at ratios of 0%, 25%, 50%, 75% and 100%, where sewage sludge and organic soil were blended with slags separately. The maximum dry unit weights and the optimum water contents for all soil mixtures were determined. In order to investigate the influence of the slags on the strength of sewage sludge and organic soil, and to obtain the optimal mix design; compaction tests, the California bearing ratio (CBR) test, unconfined compressive strength (UCS) test, hydraulic conductivity test (HCT) and pH tests were carried out on slag-soil specimens. Unconfined compressive tests were performed on non-cured samples and those cured at 7 days. The test results obtained from untreated specimens were compared to tests results obtained from soil samples treated with slag. Laboratory tests results indicated that blending slags with organic soil or sewage sludge improved the engineering properties of organic or sewage sludge. Therefore, it is concluded that slag can be potentially used as a stabilizer to improve the properties of organic soils and sewage sludge.