• Title/Summary/Keyword: transmission tower

Search Result 276, Processing Time 0.033 seconds

A Safety Analysis of Electric Detonator for Stray Currents by Domestic Transmission Network System (국내 송전계통별 미주전류에 의한 전기뇌관의 안전성 분석)

  • Park Hyun-Sik;Kim Young-Seok;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.296-304
    • /
    • 2005
  • This study is to observe stray currents generated around the steel tower by domestic transmission network system and analysis stability of electric detonator. It is measured the stay current of each ten place at steel tower of 765 kV, 345 tV, 154 tV transmission line among domestic transmission network system. Stay currents measured a total of 40m at intervals of 4m toward a line direction and a line vertical direction centering around steel tower. Temperature of the surface, EC, water content also are measured. Although stay currents show the highest values, that is 12 percent of at 4m and less than 1 percent of 40m with Institute of Makers of Explosives(IME) regulations. It is shown correlation between stay currents and water content$\cdot$EC$\cdot$temperature of the surface. Stay currents measured at line direction and line vertical direction were little different and the shape of diminution was also shown a similar aspect.

Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower (345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.14-21
    • /
    • 1998
  • In this paper, the measurements of ELF electric and magnetic fields due to double circuit 345[kV} transmission lines are made using planar-type electric field sensor and multitum loop-type magnetic field sensor, and the magnitudes of electric and magnetic fields are illustrated by a three-dimensional plot. Also, in order to predict the magnetic field strength with lad variation, a typical daily load current curves of the transmission lines are displayed because the magnetic field is changed with load current. experimental results of ELF electric and magnetic fields along center line versus lateral distance are compared with the theoretical values computed by using the FIELDS program. The electric field intensity in and around a transmission tower is lowered, and the greatest point of the magnetic field is shifted to the heavy load line but generally is given the trend that the peak value appear at the central part of the transmission tower. The magnitudes of the maximum electric and magnetic fields in the vicinity of a transmission tower are less than 3.5[kV/m] and $20[{\mu}T]$, respectively. The measured electric and magnetic fields are satisfied with limits and guidelines recommended by various authorized international institutes.

  • PDF

Calculation of Phase Center of Large Geomorphological Object on the Surface

  • Kim Jun-su;Park Sang-Eun;Kim Duk-jin;Moon Wooil M.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.741-744
    • /
    • 2005
  • A numerical scattering model for artificial metal structure based on physical optics approximation is developed to identify the height of phase center, and the result is compared with interferometric SAR DEM. The interferometric SAR data were gathered by AIRSAR during PACRIM- II campaign on Jeju Island. Power transmission towers on piedmont pasture along the slopes of Mt. Halla look like elliptic risings in TOPSAR DEM. The heights of risings are quantitatively analyzed using a scattering model in the way of achieving the height of phase centers of power transmission towers. A numerical algorithm is developed on the basis of physical optics approximation. The structure of power transmission tower was decomposed into hundreds of rectangular metal plates, of which the scattering matrix is known in analytic form, and the calculated scattering fields were summed coherently. The effect of direct backscattering component, ground-scatterer component and scatterer-ground component are decomposed and computed individually for each rectangular metal plate. The $\Deltak-radar$ equivalent was used to calculate height of phase center of the scatterer. The heights of a selected power transmission tower and scattering algorithm results give existence and location of the transmission towers but not actual tower heights.

  • PDF

A Study on Transmission Tower by Applying Polymer Insulation Arms (암절연물을 적용한 송전철탑 연구)

  • Park, Hoy-Yul;Ahn, Myeong-Sang;Lee, Tae-Joo;Lee, Dong-II;Choi, In-Hyuk;Kim, Joung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.1-4
    • /
    • 2005
  • The electric power demand is steadily high. It becomes difficult to secure the land for overhead transmission lines year after year. Downsizing of overhead transmission lines can be most effectively achieved by applying polymer insulation arm. This paper describes the outline of compact overhead transmission lines and the result of mechanical evaluation of FRP for the compact transmission towers. Bending strength of FRP was evaluated according to the fiber orientation because the fiber orientation in FRP has a great effect on the strength of FRP.

  • PDF

A Design of 150 meters high steal tower (150m 철탑의 설계 I)

  • 이재숙
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.43-56
    • /
    • 1968
  • The design of this antenna tower on the publication had been prepared by writer in order to compare with that of towers for power transmission line or to show the differences on designs existing on their design standards. The design of this antenna tower is also featuring on the following points; (1) the height of tower is 150meters high, (2) combined steel angles are adopted besides angles, (3) the direction of 45degree wind is taken account into design, (4) the additional stresses of horizontal members located in the bending points of main posts are contemplated though these additional stressess are not shown on stress diagram.

  • PDF

Seismic response and failure analyses of pile-supported transmission towers on layered ground

  • Pan, Haiyang;Li, Chao;Tian, Li
    • Structural Engineering and Mechanics
    • /
    • v.76 no.2
    • /
    • pp.223-237
    • /
    • 2020
  • Transmission towers have come to represent one of the most important infrastructures in today's society, which may suffer severe earthquakes during their service lives. However, in the conventional seismic analyses of transmission towers, the towers are normally assumed to be fixed on the ground without considering the effect of soil-structure interaction (SSI) on the pile-supported transmission tower. This assumption may lead to inaccurate seismic performance estimations of transmission towers. In the present study, the seismic response and failure analyses of pile-supported transmission towers considering SSI are comprehensively performed based on the finite element method. Specifically, two detailed finite element (FE) models of the employed pile-supported transmission tower with and without consideration of SSI effects are established in ABAQUS analysis platform, in which SSI is simulated by the classical p-y approach. A simulation method is developed to stochastically synthesize the earthquake ground motions at different soil depths (i.e. depth-varying ground motions, DVGMs). The impacts of SSI on the dynamic characteristic, seismic response and failure modes are investigated and discussed by using the generated FE models and ground motions. Numerical results show that the vibration mode shapes of the pile-supported transmission towers with and without SSI are basically same; however, SSI can significantly affect the dynamic characteristic by altering the vibration frequencies of different modes. Neglecting the SSI and the variability of earthquake motions at different depths may cause an underestimate and overestimate on the seismic responses, respectively. Moreover, the seismic failure mode of pile-supported transmission towers is also significantly impacted by the SSI and DVGMs.

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.

Total design and manufacturing system for Space Truss structure (입체 트러스 구조물의 설계 및 제작 통합 시스템 구축)

  • 이병해;김홍국;김성근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.04a
    • /
    • pp.49-56
    • /
    • 1994
  • The purpose of this study is to construct a total design & manufacturing system for the Space-Truss structure. In this study, we choose the transmission tower as the study model to show the possibility of a Total System for another space truss structure. We are confident that this total system should provide more convenience, accuracy and should help to save time from the design stage to construct stage of the transmission tower.

  • PDF

Stochastic Response Analysis of Transmission Tower Subjected to Young's Modulus Variation (송전철탑의 탄성계수의 변이에 따른 확률적 응답변이도)

  • 동원영;정영수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.207-215
    • /
    • 1993
  • With the aid of finite element method, this paper deals with the problem of structural response variability of transmission tower subjected to the spatial variability of material properties, Young's modulus herein. The spatial variability of material property are modeled as two-dimensional stochastic field which has an isotropic auto-correlation function. Response variability has been computed based on two numerical techniques, such as the Neumann expansion method in conjunction with the Monte Carlo simulation method. The results by these numerical methods are compared with those by the deterministic approach.

  • PDF

A Study on Multi-Phase Flashover in 765kV Transmission Line using EMTP (EMTP를 이용한 765kV 송전선로 다상 섬락에 관한 연구)

  • Ka, B.H.;Min, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1586-1588
    • /
    • 1998
  • To use the EMTP, in this paper, a arcing horn is simulated by non-linear resistor and inductor element using TACS, a tower by distributed parameter model, and lines as K. C. Lee model. Changing lightning current characteristics, lightning position, and tower footing resistor value, we analysis multi-phase flashover characteristics in 765 kV transmission line.

  • PDF