• 제목/요약/키워드: transmission power

검색결과 5,780건 처리시간 0.044초

혼합 정수 선형 계획법 기반의 최적 경제 급전을 활용한 분산형 열병합 발전원의 송전선로 건설비용 회피 편익계산 (Calculating the Benefit of Distributed Combined Heat Power Generators from Avoiding a Transmission Expansion Cost by Solving a Mixed Integer Linear Programming)

  • 권욱현;박용기;노재형;박종배;이두희
    • 전기학회논문지
    • /
    • 제68권4호
    • /
    • pp.513-522
    • /
    • 2019
  • We calculate the benefit of distributed combined heat power generators from avoiding a transmission expansion cost by building distributed generators near electricity demand centers. We determine a transmission expansion plan by solving a mixed integer linear problem, where we modify capacities of existing transmission lines and build new transmission lines. We calculate the benefit by comparing the sum of generation and transmission expansion costs with or without distributed generators through two simulation frames. In the first frame, for the current demand, we substitute existing distributed generators for non-distributed generators and measure an additional cost to balance the generation and demand. In the second frame, for increased future demand, we compare the cost to invest only in distributed generators to the cost to invest only in non-distributed generators. As a result, we show that the distributed generators have at least 5.8 won/kWh of the benefit from avoiding the transmission expansion cost.

도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구 (Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor)

  • 신구용;권구민;송성환;우정욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.141-147
    • /
    • 2019
  • 최근 전력산업에 가장 커다란 이슈는 신재생에너지의 증가이며 이에 따라 전력계통의 수용성을 확보하기 위한 다양한 기술개발이 추진되고 있다. 또한 세계적으로 보다 융통성 있는 친환경 에너지의 활용을 위하여 국가 및 지역간 전력계통을 연계하는 슈퍼그리드의 구성이 추진되고 있다. 이러한 성격이 서로 다른 계통 간에 연계를 위하여 반드시 요구되는 기술이 초고압 직류송전기술이다. 지금까지 국내에서는 육지와 제주도를 해저케이블로 연결하는 HVDC 송전기술이 적용되었으나 동해안의 발전단지에서 수도권의 부하밀집 지역으로 장거리 대용량 전력전송을 위한 직류가공송전 방식의 기술개발이 추진되고 있다. 인구밀도가 높고 산악이 많은 국내 환경을 고려해 최소한의 경과를 활용하여 8 GW 급의 대용량 전력을 전송하기 위해 도체귀로방식의 ${\pm}500kV$ Double Bipole 송전선로 설계기술을 개발하고 이를 적용하기 위한 사업화를 추진하고 있다. 본 논문에서는 세계 최초로 적용 예정인 도체귀로방식의 Double Bipole 송전선로의 설계를 위한 절연특성에 관한 연구를 수행하고 송전선로에 발생하는 다양한 과전압현상에 견디는 공기절연특성을 실증시험을 통하여 검증하고 이를 서술하였다.

디지털 위성방송 시스템의 고속 서비스를 위한 Pulse Shaping Filter 설계 (Design of Pulse Shaping Filter for High-Speed Service in Digital Satellite Broadcasting System)

  • 오재현;이인섭;이완범;강정용;박형근;김환용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.337-340
    • /
    • 2002
  • In data transmission at the digital satellite broadcasting systems, the delay and spread are caused whit receiving original signals from the transmitter in the receiver. So, there are some problems in data fast transmission. Also, transmitted signals ate received in stale of the combination of transmission delay and noise of channel. The affect of channel noise is reduced when increasing transmission power, but as signal interference due to the transmission delay and spread of channel increase in proportion to the transmission power, there is a problem in spite of increasing the transmission power. And there is the problem to add ISI(inter symbol interference) because the property of the channel is limo-varying due to relative moving in the transceiver Therefore, in this paper, a pulse shaping filter for the high-speed service in digital satellite broadcasting systems was designed and reduced the ISI.

  • PDF

송전선로 DC화에 따른 융통조류 마진 분석 (Analysis of system power flow margin on replacement of transmission line to DC line)

  • 황성철;이재형;황평익;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF

트랙터 8단 자동변속기 기어 열 설계 (Gear Train Design of 8-Speed Automatic Transmission for Tractor)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권2호
    • /
    • pp.30-36
    • /
    • 2013
  • Tractor is a farm vehicle that is designed to provide a high tractive effort at low speed. It is used for versatile agricultural tasks such as hauling a trailer, tillage, mowing and construction work. Most older tractors use a manual transmission. However, as the intensity of work increases, tractors equipped with automatic transmission become popular due to the work convenience. In order to give the operator a large degree of control in field work, 24 gears with automatic 8-speed and manual 3-speed are arranged in transmission. This paper deals with the gear train that is designed for 8-speed automatic transmission by the engagement of multi-disk clutches. The gear ratio for each speed as well as power transmission mechanism is analyzed through velocity analysis. In addition, constraints of mesh gear ratio are derived by investigating the power flow path in velocity diagram for the given 8-speed gear ratio.

혼합송전선로 편단접지 구간 과전압 저감 방안에 관한 연구 (A Study on Overvoltage Reduction Method of Single Point Bonded Section on Combined Transmission Lines)

  • 정채균;강지원;박흥석;김진
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1881-1887
    • /
    • 2009
  • This paper discusses the effects of ECC (Earth Continuity Conductor) for reducing the level of induced sheath overvoltages at the single point bonded section of combined transmission lines which are mixed underground power cable with overhead line in one T/L. In previous papers, the characteristics of ECC on only underground power cable systems were sufficiently analyzed. However, the result of only underground power cable systems are totally different from that of combined transmission lines because ECC is commonly grounded with overhead grounding wire at mesh of cable head. Therefore, in this paper, the installation effects of ECC have been variously analyzed considering the three kinds of fault positions, cable formation of duct and trefoil, spacing between phase conductor and ECC, and the change of overhead transmission line section length on 154kV combined transmission line. Finally, simulation results show that ECC can effectively reduce the induced sheath voltage.

Cross-Entropy를 이용한 전력계통계획의 확률적 기법 연구 (Probabilistic Technique for Power System Transmission Planning Using Cross-Entropy Method)

  • 이재희;주성관
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2136-2141
    • /
    • 2009
  • Transmission planning is an important part of power system planning to meet an increasing demand for electricity. The objective of transmission expansion is to minimize operational and construction costs subject to system constraints. There is inherent uncertainty in transmission planning due to errors in forecasted demand and fuel costs. Therefore, transmission planning process is not reliable if the uncertainty is not taken into account. The paper presents a systematic method to find the optimal location and amount of transmission expansion using Cross-Entropy (CE) incorporating uncertainties about future power system conditions. Numerical results are presented to demonstrate the performance of the proposed method.

전력구 터널 내 전력선 발열 시 환기방식에 따른 온도분포에 대한 전산해석 (Numerical Simulation on the Temperature Distribution by Ventilation Type during Heat of the Power line in Electric Power Tunnel)

  • 이호형;이승철;곽동걸;백두산
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.3-4
    • /
    • 2014
  • Power line in electric power tunnel generate heat around during power transmission. Rising temperature inside the electric power tunnel reduces the transmission efficiency of the power line. In this study, trying to understand the change in temperature in the electric power tunnel by forced ventilation and natural ventilation when the temperature rise of the electric power tunnel. The results show that average temperature in electric power tunnel by natural ventilation, forced ventilation is $56.55^{\circ}C$, $23.25^{\circ}C$. Therefore electric power tunnel during power transmission needs cooling or ventilation system.

  • PDF

HVDC시스템 밸브홀의 기계적 강도 계산 (Mechanical Strength Calculation of HVDC Valve Hall)

  • 김찬기;이성두;강지원;윤용범
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.442-448
    • /
    • 2016
  • This paper presents electromagnetic force effect of the conductor and insulator in the HVDC valve hall. This paper is based on IEC 60865, which is applicable to the mechanical and thermal effects of short-circuit currents. The paper contains procedures for the calculation of the electromagnetic effect on HVDC conductors and flexible conductors, as well as the thermal effect on HVDC conductors. The results are applied to the Godeok -Dangjin HVDC system.

Integrated Generation and Transmission Expansion Planning Using Generalized Bender’s Decomposition Method

  • Kim, Hyoungtae;Lee, Sungwoo;Kim, Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2228-2239
    • /
    • 2015
  • A novel integrated optimization method based on the Generalized Bender’s Decomposition (GBD) is proposed to combine both generation and transmission expansion problems. Most of existing researches on the integrated expansion planning based on the GBD theory incorporate DC power flow model to guarantee the convergence and improve the computation time. Inherently the GBD algorithm based on DC power flow model cannot consider variables and constraints related bus voltages and reactive power. In this paper, an integrated optimization method using the GBD algorithm based on a linearized AC power flow model is proposed to resolve aforementioned drawback. The proposed method has been successfully applied to Garver’s six-bus system and the IEEE 30-bus system which are frequently used power systems for transmission expansion planning studies.