• Title/Summary/Keyword: transmission power

Search Result 5,780, Processing Time 0.037 seconds

An Improved Dynamic Programming Approach to Economic Power Dispatch with Generator Constraints and Transmission Losses

  • Balamurugan, R.;Subramanian, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.320-330
    • /
    • 2008
  • This paper presents an improved dynamic programming (IDP) approach to solve the economic power dispatch problem including transmission losses in power systems. A detailed mathematical derivation of recursive dynamic programming approach for the economic power dispatch problem with transmission losses is presented. The transmission losses are augmented with the objective function using price factor. The generalized expression for optimal scheduling of thermal generating units derived in this article can be implemented for the solution of the economic power dispatch problem of a large-scale system. Six-unit, fifteen-unit, and forty-unit sample systems with non-linear characteristics of the generator, such as ramp-rate limits and prohibited operating zones are considered to illustrate the effectiveness of the proposed method. The proposed method results have been compared with the results of genetic algorithm and particle swarm optimization methods reported in the literature. Test results show that the proposed IDP approach can obtain a higher quality solution with better performance.

Development of a Measuring Instrument of Current and Voltage on Power-Transmission Lines for the Construction of Energy-Network

  • Park, Kyi-Hwan;Jiang, Zhongwei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.107.2-107
    • /
    • 2001
  • We propose portable equipment that monitors a current and potential on high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to a hollow insulator that supports a power transmission line: A current on a power line is detected by an air-core solenoidal coil clamped to the line and the detected current signal is transmitted to the ground station by using optical data link, A potential on a power transmission line is detected by a high resistance element, zinc oxide (ZnO) that acts as a potential divider between the power line and the ground. The equipment does not require high potential insulators and magnetic cores which. This leads to the following advantages of the equipment: (a) It is easily installed owing to its small size and its simple structure; (b) It operates in low ...

  • PDF

Dispersion Managed Optical Transmission Links with Optimized Optical Phase Conjugator

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.3
    • /
    • pp.372-376
    • /
    • 2009
  • In this paper, new and simple optical transmission link with fixed dispersion management (DM) scheme, i.e., pre(post) compensation and residual dispersion per span (RDPS) are fixed to net residual dispersion (NRD) = 0 ps/nm, and optical phase conjugator (OPC) having optimal position depending on launch power in WDM transmission system is proposed. Also, effective launch power range of WDM channels resulting 1 dB eye opening penalty (EOP) is induced as a function of OPC position. First, it is confirmed that, for applying DM into WDM transmission link fixed pre(post)compensation and RDPS, which are independence on exact system parameters except launch power, sufficiently are used in WDM links, but OPC with optimal position is needed for effective compensating impairments of WDM channels. And, it is confirmed that effective launch power is broader in case of RDPS = 100 ps/nm than in RDPS = 50 ps/nm. But, it is shown that the best OPC position offset is -0.6 km from a point of view of power window, which is defined as difference between maximum and minimum effective launch power.

Minimizing Power Transmission Losses by Optimum Control of Reactive Power Flow (무효전력조류의 최적제어에 의한 전력손실 최소화 연구)

  • 김준현;유석구
    • 전기의세계
    • /
    • v.28 no.10
    • /
    • pp.41-47
    • /
    • 1979
  • The paper develops a method of minimizing power transmission losses by optimum control of reactive power flow. In the past, because the optimizing method considers as the first step the minimization of node voltage deviations and as the second step the minimization of transmission losses within the system, the calculating procedure was more complex and difficult to handle. In this paper, a new computing method for real time control on a digital computer is described which aims at a coordinated use of reactive power sources and voltage regulating devices. The power transmission losses are minimized by a gradient method while satisfying the constrained system voltage conditions and sensitivity parameters are the basis of the method.

  • PDF

Analysis on Market Power in Power Transaction with Transmission Constraints (송전선 제약조건에 따른 전력거래에서의 시장지배력 연구)

  • Lee, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.403-408
    • /
    • 2002
  • As the electricity industry undergoes a process of fundamental restructuring, horizontal market power appears as a potential obstacle to a fully competitive wholesale electricity market. Market power is the ability profitably to maintain prices above competitive levels by restricting output below competitive levels. In models for imperfect competition under the consideration of the transmission constraints, the Nash equilibrium has the form of a mixed strategy. In this paper, the models for analyzing imperfect competition are compared using the solution of pure and mixed equilibria. The relation between market power and the capacity of a transmission line is investigated by imperfect competition analysis methods: Cournot, Bertrand, and Supply Curve model.

Urgency-Aware Adaptive Routing Protocol for Energy-Harvesting Wireless Sensor Networks

  • Kang, Min-Seung;Park, Hyung-Kun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.25-33
    • /
    • 2021
  • Energy-harvesting wireless sensor networks(EH-WSNs) can collect energy from the environment and overcome the technical limitations of existing power. Since the transmission distance in a wireless sensor network is limited, the data are delivered to the destination node through multi-hop routing. In EH-WSNs, the routing protocol should consider the power situations of nodes, which is determined by the remaining power and energy-harvesting rate. In addition, in applications such as environmental monitoring, when there are urgent data, the routing protocol should be able to transmit it stably and quickly. This paper proposes an adaptive routing protocol that satisfies different requirements of normal and urgent data. To extend network lifetime, the proposed routing protocol reduces power imbalance for normal data and also minimizes transmission latency by controlling the transmission power for urgent data. Simulation results show that the proposed adaptive routing can improve network lifetime by mitigating the power imbalance and greatly reduce the transmission delay of urgent data.

A Resonance Power Combining Technique Using CRLH-Transmission Line (CRLH 전송 선로를 이용한 공진 기법의 전력 결합 기술)

  • Kim, Ell-Kou;Kim, Young;Kwon, Sang-Keun;Yoon, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.673-679
    • /
    • 2009
  • This paper proposes a resonance power-combining technique using CRLH-transmission line. The circuits using proposed technique consist of the parallel capacitances and transmission lines to satisfy matching conditions and to combine power of amplifiers. The CRLH(Composite Right/Lefi-Handed) transmission lines are used to reduce the circuit size. As a result, the power combining amplifier using proposed techniques is measured that a gain is equal and the output power is increased about 2.2 dB higher than the single amplifier. Also, a size of amplifier is 78.3 % smaller than the conventional amplifier using RH transmission line.

Design of Power Transmission System of a Water Bike (수상 자전거의 동력전달장치 설계)

  • Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.3
    • /
    • pp.153-159
    • /
    • 2013
  • The power transmission system has always been considered critical for a human powered boat(or water bike) since it first showed up at Human Powered Vessel Festival. Mechanical problems, such as abrasions and other damages of the gear system for the power transmission, lead to poor durability and low efficiency of a boat. This paper described mechanical problems and a design process of power transmission system and then suggested the method to solve the problems. It is selected a module and a type of gears that are structurally stable thus can transmit the power durable. Especially the lower gear box is applied to CRP(contra rotating propeller) system for improving the structural stability and the propeller efficiency as well. As the results, the upper and lower gear box are designed and manufactured. And from the trial test, it is confirmed that the power transmission system is reliable.

A Study on the Impact of HVDC Transmission System to Interconnect Large-scale Power Generation Plants to Power Grid in Korea (HVDC 송전을 이용한 동해안 신규전원의 수도권 계통 연계방안에 대한 연구)

  • Han, Su-Young;Gwon, Do-Hun;Chung, Il-Yop;Lim, Jae-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1647-1656
    • /
    • 2013
  • Although the demand for electricity has been increasing these days, it becomes more difficult to find new sites for large-scale power generation plants near urban areas due to environmental and economic issues. Therefore, new power plants are forced off to rural or desolate coastal areas. As a result, there is significant regional imbalance in power generation and consumption between urban and rural areas in South Korea. This paper investigates the feasibility of high-voltage DC (HVDC) system as a candidate for electric power transmission system from east-coastal sites to metropolitan area. To this end, this paper analyzes transient stability and dynamic impact of a HVDC transmission system and compares the results to conventional high-voltage AC (HVAC) transmission systems via PSS/E simulation. This paper also examines the effect of HVDC system to voltage variation and low-frequency resonance in the neighboring buses in the grid using ESCR(Effective Short Circuit Ratio)과 UIF(Unit Interaction Factor) indices.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.