• Title/Summary/Keyword: transmission map

Search Result 258, Processing Time 0.031 seconds

Security Analysis of KS X 4600-1 / ISO IEC 12139-1 (원격 검첨용 PLC 기술(KS X 4600-1 / ISO IEC 12139-1) 보안성 분석)

  • Hong, Jeong-Dae;Cheon, Jung-Hee;Ju, Seong-Ho;Choi, Moon-Suk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.1
    • /
    • pp.65-75
    • /
    • 2011
  • Power Line Communication (PLC) is a system for carrying data on a conductor used for electric power transmission. Recently, PLC has received much attention due to connection efficiency and possibility of extension. It can be used for not only alternative communication, in which communication line is not sufficient, but also for communication between home appliances. Korea Electronic Power Cooperation (KEPCO) is constructing the system, which automatically collects values of power consumption of every household. Due to the randomness and complicated physical characteristics of PLC protocol (KS X4600-1), it has been believed that the current PLC is secure in the sense that it is hard that an attacker guesses or modifies the value of power consumption. However, we show that the randomness of the protocol is closely related to state of the communication line and thus anyone can easily guess the randomness by checking the state of the communication line. In order to analyze the security of PLC, we study the protocol in detail and show some vulnerability. In addition, we suggest that PLC needs more secure protocol on higher layers. We expect that the study of PLC help in designing more secure protocol as well.

Individual Ortho-rectification of Coast Guard Aerial Images for Oil Spill Monitoring (유출유 모니터링을 위한 해경 항공 영상의 개별정사보정)

  • Oh, Youngon;Bui, An Ngoc;Choi, Kyoungah;Lee, Impyeong
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1479-1488
    • /
    • 2022
  • Accidents in which oil spills occur intermittently in the ocean due to ship collisions and sinkings. In order to prepare prompt countermeasures when such an accident occurs, it is necessary to accurately identify the current status of spilled oil. To this end, the Coast Guard patrols the target area with a fixed-wing airplane or helicopter and checks it with the naked eye or video, but it was difficult to determine the area contaminated by the spilled oil and its exact location on the map. Accordingly, this study develops a technology for direct ortho-rectification by automatically geo-referencing aerial images collected by the Coast Guard without individual ground reference points to identify the current status of spilled oil. First, meta information required for georeferencing is extracted from a visualized screen of sensor information such as video by optical character recognition (OCR). Based on the extracted information, the external orientation parameters of the image are determined. Images are individually orthorectified using the determined the external orientation parameters. The accuracy of individual orthoimages generated through this method was evaluated to be about tens of meters up to 100 m. The accuracy level was reasonably acceptable considering the inherent errors of the position and attitude sensors, the inaccuracies in the internal orientation parameters such as camera focal length, without using no ground control points. It is judged to be an appropriate level for identifying the current status of spilled oil contaminated areas in the sea. In the future, if real-time transmission of images captured during flight becomes possible, individual orthoimages can be generated in real time through the proposed individual orthorectification technology. Based on this, it can be effectively used to quickly identify the current status of spilled oil contamination and establish countermeasures.

Changes of Qualities of Green Asparagus Packed with Different Types during Low Temperature Storage (포장 방법에 따른 아스파라거스의 저온저장 중 품질변화)

  • Wang, Lixia;Choi, In-Lee;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.239-244
    • /
    • 2020
  • Effect of 6kg large unit with the carton box (20% open ratio) and MA box (10,000cc·m-2·day-1·atm-1 oxygen transmission rates modified atmosphere package), and the 100g small unit with MA film on asparagus sensory quality were evaluated. The CO2 concentration depended largely on the packing unit and maintained at around 3% in small MA packages, whereas in the MA box increased to 12%. Ethylene concentration rapidly increased until after 3 days of storage in MA packages and then decreased to maintain 5μL·L-1. Unrelated to the unit size, the lower weight loss was obtained in MA packages. A significant difference in visual quality was shown since the 15th day, the best and worst were the MA box and small MA package on the finish day. Off-odor was the highest in small MA packages and the lowest in the carton box (< 3.0). Although there was no significant difference in firmness among all treatments, the packages showed the highest firmness in tips and stems, respectively. The sugar content and hue angle decreased during storage, but there was no statistical difference in all treatments. EL was lowest and highest in small MA package and carton box, respectively. On the 10th day, the total aerobic bacteria was lowest in small MA packages, but no significant difference on the 20th day. E. coli was not found in all treatments on the 10th day, while it was the lowest in the MA box on the 20th day. The mold and yeast were not observed during the whole storage. Based on the above results, the carton box packaged with 10,000cc OTR film was more effective in maintaining the quality of green asparagus with the suitable CO2 concentration for asparagus cold storage.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Effect of Seasonal Distribution Temperature on Storability of Modified Atmosphere Packaged Baby Leaf Beet (계절별 수송 온도가 MA 포장한 어린잎 비트의 저장성에 미치는 영향)

  • Choi, In-Lee;Han, Su Jung;Kim, Ju Young;Ko, Young-Wook;Kim, Yongduk;Hwang, Myung-Keun;Yu, Wanggun;Kang, Ho-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.2
    • /
    • pp.85-89
    • /
    • 2018
  • The effects of distribution temperature due to season all changes on quality and storability of baby leaf beet (Beta vulgaris L.) was examined in modified atmosphere (MA) packages. The beet leaf had been harvested at the 10 cm leaf length stage and packaged with an oxygen transmission rate (OTR) film of $1,300cc{\cdot}m^{-2}{\cdot}day^{-1}{\cdot}atm^{-1}$ and then held at 4 different distribution temperatures which were $-2^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$, or $30^{\circ}C$ for 5 hrs and then stored for 18 days at $8^{\circ}C$. The loss of fresh weight of packged baby leaf beet was lowest at the $4^{\circ}C$ treatment, and below 0.6% in all distribution temperature treatments. The atmosphere composition in packages did not show any significant differences among treatments. The oxygen conc. was the highest at 18.0% after the $4^{\circ}C$ treatment, carbon dioxide conc. showed the maximum value of 4% at the $30^{\circ}C$ and $-2^{\circ}C$ treatments, and ethylene conc. was highest at the $10^{\circ}C$ treatment after 10 days in storage. The hardness was the highest at the $4^{\circ}C$ treatment on the final storage day. The $4^{\circ}C$ treatment showed the highest visual quality and the lowest off-odor and aerobic plate count. Therefore, it is necessary to establish a low-temperature distribution system which is controlled under $4^{\circ}C$, because the baby leaf beet's storability and microbial growth are effected even during a short time of 5 hrs during the distribution process.

Comparison of Leaf Color and Storability of Mixed Baby Leaf Vegetables according to the Mixing Ratios of Red Romaine lettuces (Lactuca sativa), Peucedanum japoincum, and Ligularia stenocephala during MA Storage (MA저장중 혼합비율에 따른 적로메인, 갯기름나물, 그리고 곤달비 혼합 어린잎채소의 엽색과 저장성 비교)

  • Choi, In-Lee;Lee, Joo Hwan;Wang, Li-Xia;Park, Wan Geun;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.77-84
    • /
    • 2021
  • This study attempted to find a way to maintain the quality of mixing baby wild leaf vegetables with existing baby leaf vegetables in various ratios. The crops for mixing baby leaf vegetables were Peucedanum japoincum Thunberg and Ligularia stenocephala, as wild vegetables, and red romaine, which is widely used in young leafy vegetables. The mixing ratio of red romaine and wild vegetables was red romaine 0: mantilla oil 5: L. stenocephala ratio 5 (R0: P5: L5), red romaine 3.3: P. japoincum 3.3: L. stenocephala ratio 3.3 (R3.3: P3.3: L3.3), red romaine 5: P. japoincum 2.5: L. stenocephala 2.5 (R5: P2.5: L2.5), red romaine 8: P. japoincum 1: L. stenocephala 1 (R8: P1: L1), red romaine 10: P. japoincum 0: L. stenocephala 0 (R10: P0: L0). All treatments were packaged in OTR (oxygen transmittance) 10,000 cc m-2·day-1·atm-1 film and stored for 27 days at 2℃/85% RH conditions. Fresh weight, carbon dioxide, oxygen, and ethylene concentrations of the baby leaf packages were examined approximately every 3 days, and visual quality, chlorophyll content, and chromaticity were examined on the 27th day of storage. The oxygen and carbon dioxide concentration in the packages were affected by the respiration rate of the crop. As the mixing ratio of lettuce, which had a low respiration rate, increased, the oxygen concentration in the packages was higher and the carbon dioxide concentration was lower. Oxygen concentration decreased significantly after 15 days, but was remained above 16%, and on the contrary, carbon dioxide concentration was kept at 1-4% until the 15th, and then gradually increased to 2-5% on the 27th day. The concentration of ethylene was maintained at 3-6 µL·L-1 until the end of storage (27th day). Visual quality score measured at the end of storage was slightly less than 3.0, which is the limit of marketability of all treatments. Although there was no significant difference, the chlorophyll content (SPAD) of red romaine and P. japoincum were most similar with an initial value in R8:P1:1 treatment, and L. stenocephala was higher value in R8:P1:L1 and R5:P2.5:L2.5 treatments at the end of storage. The leaf color (L∗, a∗, b∗, chroma) of the three crops at end of storage compared with the heat map showed the least change in the R5:P2.5:L2.5 and R8:P1:L1 treatments at the end of storage. Among them, R8:P1:L1 treatment maintained the highest chlorophyll content, the second lowest ethylene concentration, and adequate carbon dioxide concentration of 2-3%. Therefore, it is judged that the mixed ratio of red romaine 8: P. japoincum 1: L. stenocephala 1 (R8: P1: L1) is most suitable for the mixed package of baby leaf vegetables of these three crops.

Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction (CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정)

  • Choi, Joon-Young;Woo, Sang-Keun;Choi, Yong;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.49-53
    • /
    • 2007
  • Purpose: It was reported that CT-based measured attenuation correction (CT-MAC) produced radioactivity concentration values significantly higher than $^{68}Ge$-based segmented attenuation correction (Ge-SAC) in PET images. However, it was unknown whether the radioactivity concentration difference resulted from different sources (CT vs. Ge) or types (MAC vs. SAC) of attenuation correction (AC). We evaluated the influences of the source and type of AC on the radioactivity concentration differences between reconstructed PET images in normal subjects and patients. Material and Methods: Five normal subjects and 35 patients with a known or suspected cancer underwent $^{18}F-FDG$ PET/CT. In each subject, attenuation corrected PET images using OSEM algorithm (28 subsets, 2 iterations) were reconstructed by 4 methods: CT-MAC, CT-SAC, Ge-MAC, and Ge-SAC. The physiological uptake in normal subjects and pathological uptake in patients were quantitatively compared between the PET images according to the source and type of AC. Results: The SUVs of physiological uptake measured in CT-MAC PET images were significantly higher than other 3 differently corrected PET images. Maximum SUVs of the 145 foci with abnormal FDG uptake in CT-MAC images were significantly highest among 4 differently corrected PET images with a difference of 2.4% to 5.1% (p<0.001). The SUVs of pathological uptake in Ge-MAC images were significantly higher than those in CT-SAC and Ge-MAC PET images (p<0.001). Conclusion: Quantitative radioactivity values were highest in CT-MAC PET images. The adoption of MAC may make a more contribution than the adoption of CT attenuation map to such differences.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.