• 제목/요약/키워드: transient thermal loads

검색결과 29건 처리시간 0.039초

THERMAL AND STRUCTURAL ANALYSIS OF CALANDRIA VESSEL OF A PHWR DURING A SEVERE ACCIDENT

  • Kulkarni, P.P.;Prasad, S.V.;Nayak, A.K.;Vijayan, P.K.
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.469-476
    • /
    • 2013
  • In a postulated severe core damage accident in a PHWR, multiple failures of core cooling systems may lead to the collapse of pressure tubes and calandria tubes, which may ultimately relocate inside the calandria vessel forming a terminal debris bed. The debris bed, which may reach high temperatures due to the decay heat, is cooled by the moderator in the calandria. With time, the moderator is evaporated and after some time, a hot dry debris bed is formed. The debris bed transfers heat to the calandria vault water which acts as the ultimate heat sink. However, the questions remain: how long would the vault water be an ultimate heat sink, and what would be the failure mode of the calandria vessel if the heat sink capability of the reactor vault water is lost? In the present study, a numerical analysis is performed to evaluate the thermal loads and the stresses in the calandria vessel following the above accident scenario. The heat transfer from the molten corium pool to the surrounding is assumed to be by a combination of radiation, conduction, and convection from the calandria vessel wall to the vault water. From the temperature distribution in the vessel wall, the transient thermal loads have been evaluated. The strain rate and the vessel failure have been evaluated for the above scenario.

초고주파 탐색기 신호처리부의 방열설계에 관한 연구 (A Study on the Thermal Design for A Signal Processor in the Micro-Wave Seeker)

  • 이원희;유영준;김호용
    • 한국항공우주학회지
    • /
    • 제39권1호
    • /
    • pp.76-83
    • /
    • 2011
  • 본 논문에서는 초고주파 탐색기 신호처리부의 방열설계 과정을 연구하였다. 신호처리부는 고온환경조건과 초기고장배제시험 조건을 고려하여 설계되어져야 한다. 우선, 신호처리부의 열적 신뢰성 검증을 위하여 전산 열해석을 수행하였으며, 해석 결과를 바탕으로 열적으로 취약한 소자에 방열 블록을 적용하였다. 이 기술은 방열블록이 각각의 소자의 열 부하를 조절하기 때문에 효율적인 방열을 할 수 있게 된다. 다음으로 전산모델 결과와 실험 결과를 검증하였으며, 이를 통하여 신호처리부의 열적 신뢰성을 확인하였다. 또한 실험결과와 해석결과의 최대 온도차가 약 $2^{\circ}C$ 임을 알 수 있다.

Comparative dynamic studies of thick laminated composite shells based on higher-order theories

  • Ganapathi, M.;Patel, B.P.;Pawargi, D.S.;Patel, H.G.
    • Structural Engineering and Mechanics
    • /
    • 제13권6호
    • /
    • pp.695-711
    • /
    • 2002
  • Here, the dynamic response characteristics of thick cross-ply laminated composite cylindrical shells are studied using a higher-order displacement model. The formulation accounts for the nonlinear variation of the in-plane and transverse displacements through the thickness, and abrupt discontinuity in slope of the in-plane displacements at any interface. The effect of inplane and rotary inertia terms is included. The analysis is carried out using finite element approach. The influences of various terms in the higher-order displacement field on the free vibrations, and transient dynamic response characteristics of cylindrical composite shells subjected to thermal and mechanical loads are analyzed.

Non-linear fire-resistance analysis of reinforced concrete beams

  • Bratina, Sebastjan;Planinc, Igor;Saje, Miran;Turk, Goran
    • Structural Engineering and Mechanics
    • /
    • 제16권6호
    • /
    • pp.695-712
    • /
    • 2003
  • The non-linear structural analysis of reinforced concrete beams in fire consists of three separate steps: (i) The estimation of the rise of surrounding air temperature due to fire; (ii) the determination of the distribution of the temperature within the beam during fire; (iii) the evaluation of the mechanical response due to simultaneous time-dependent thermal and mechanical loads. Steps (ii) and (iii) are dealt with in the present paper. We present a two-step computational procedure where a 2D transient thermal analysis over the cross-sections of beams are made first, followed by mechanical analysis of the structure. Fundamental to the accuracy of the mechanical analysis is a new planar beam finite element. The effects of plasticity in concrete, and plasticity and viscous creep in steel are taken into consideration. The properties of concrete and steel along with the values of their thermal and mechanical parameters are taken according to the European standard ENV 1992-1-2 (1995). The comparison of our numerical and full-scale experimental results shows that the proposed mechanical and 2D thermal computational procedure is capable to describe the actual response of reinforced concrete beam structures to fire.

두개의 제어기를 사용한 건물 내부의 온도변화와 에너지소비량을 계산하기 위한 해석적 연구 (A study on the analytical method for calculating the inside air temperature transient and energy consumption load of the building using two different controllers)

  • 한규일
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.82-90
    • /
    • 2012
  • Four different buildings having various wall construction are analyzed for the effect of wall mass on the thermal performance and inside building air and wall temperature transient and also for calculating the energy consumption load. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one-dimensional, linear, partial differential equations is obtained using the Laplace transform method, Bromwich and modified Bromwich contour method. A simple dynamic model using steady state analysis as simplified methods is developed and results of energy consumption loads are compared with results obtained using the analytical solution. Typical Meteorological Year data are processed to yield hourly average monthly values. This study is conducted using weather data from two different locations in Korea: Daegu having severe weather in summer and winter and Jeju having mild weather almost all year round. There is a significant wall mass effect on the thermal performance of a building in mild weather condition. Buildings of heavyweight construction with insulation show the highest comfort level in mild weather condition. A proportional controller provides the higher comfort level in comparison with buildings using on-off controller. The steady state analysis gives an accurate estimate of energy load for all types of construction. Finally, it appears that both mass and wall insulation are important factors in the thermal performance of buildings, but their relative merits should be decided in each building by a strict analysis of the building layout, weather conditions and site condition.

온도의존성 열특성 계수를 고려한 화재에 노출된 철근콘크리트 골조의 해석적 연구 (Temperature-Dependency Thermal Properties and Transient Thermal Analysis of Structural Frames Exposed to Fire)

  • 한병찬;권영진;김재환;신영수;최은규
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.283-292
    • /
    • 2007
  • 본 연구는 화재에 노출된 철근콘크리트 구조물의 열적 특성 및 구조 거동을 예측할 수 있는 비정상 온도 분포 해석 및 비선형 유한요소해석 기법 개발에 관한 것으로써, 범용 유한요소해석 프로그램인 DIANA를 이용하여 화재에 의한 고온을 받는 철근콘크리트 구조에 대한 수치해석을 수행하고 그 결과를 비교분석하였다. 고온을 받는 철근콘크리트 골조에 대한 수치해석은 시간의존 비정상 온도 분포 해석과 비선형 유한요소해석의 2단계로 진행된다. 비정상 온도 분포 해석에서는 열전도율, 열용량, 열팽창계수에 대한 시간의존 변수를 온도 함수로 표현하여 이를 고려하였으며, 비선형 유한요소해석에 있어서는 콘크리트의 비선형성과 균열을 고려하기 위하여 파괴 역학적 관점을 도입하였다. 또한 철근콘크리트 단순보에 대한 내화 실험을 실시하여, 재료의 열적 특성 및 해석 기법에 대한 검증을 실시하였다. 이러한 해석 기법을 철근콘크리트 골조로 확장하여 열에 의한 콘크리트 및 철근의 역학적 물성 변화 요인을 고려한 해석을 통하여 각각의 변수에 대한 비교 분석을 수행하였다. 본 연구에서의 고온 환경하의 철근콘크리트 구조물에 대한 비선형 유한요소해석기법은 온도에 따른 재료의 열적 특성 및 역학적 성능 및 화재-온도 곡선을 자유롭게 입력하여 고려할 수 있으며, 추후 관련 해석에 용이하게 사용될 수 있을 것으로 판단되었다.

열-음향 복합하중에 놓인 등방성 평판의 비선형 응답특성 (Nonlinear Transient Responses of Isotropic Plates Under Thermo-Acoustic Load)

  • 오일권;성태홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.235-238
    • /
    • 2006
  • For high-speed aircraft and high-speed civil transport planes, certain structural skin components are subjected to very large acoustic loads in an elevated thermal environment. In this study, we used the single-mode Fokker-Panck distribution to predict displacements of isotropic plates subject to thermo-acoustic combined load. The single mode was formulated to predict the nonlinear dynamic responses of postbuckled plates under acoustic random excitation. Acoustic random excitation was used with Gauss distribution. Some important effects of the snap-through motion on the dynamic responses of the postbuckled plates are described.

  • PDF

원전 방진기 검사 및 관리 현황 (Status of Inspection and Management for Nuclear Power Plants Snubbers)

  • 조용배;문균영;유현주
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.20-24
    • /
    • 2014
  • Recently, it is getting more and more important ensuring the integrity for the equipment degradation according to the increase of nuclear power plant operating period. In many equipment of the nuclear power plant, snubbers mainly installed in reactor coolant pumps, steam generators and piping protected the equipment and piping from the occurrence of transient dynamic loads such as the earthquake, thermal load during the plant operation. This report describes the function, regulation, inspection requirements and management status of the snubbers installed in domestic nuclear power plants.

설계하중 및 고온을 받은 초고강도 콘크리트의 잔존압축강도 및 변형 특성 평가 (Evaluation on Residual Compressive Strength and Strain Properties of Ultra High Strength Concrete with Design Load and Elevated Temperature)

  • 윤민호;김규용;남정수;윤종일;배창오;최경철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.263-264
    • /
    • 2012
  • In this study, the ultra high strength concrete which have 100, 150, 200MPa took the heat from 20℃ to 70 0℃ and the 0, 20% stress in normal condition's to evaluate stress-strain, residual compressive strength and thermal expansion deformation were evaluated. The heating speed of specimen was 0.77℃/min 20~50℃, 50℃ before the target temperature, and the other interval's heating speed was 1℃/min. As a result, the stress-strain curve of non-load specimen showed the liner behavior at high temperature when the specimen's strength increased more. If ultra high strength concrete got loads, its compressive strength tended to decrease different from the normal strength concrete. The thermal expansion deformation was expanded from a vitrification of quartz over 500℃. however, over the 600℃, it was shrinked because of the dehydration of the combined water.

  • PDF

창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석 (Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung)

  • 김민휘;김진효;권오현;한욱;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF