• 제목/요약/키워드: transient thermal behavior

검색결과 162건 처리시간 0.023초

Transient dynamic analysis of sandwich beam subjected to thermal and pulse load

  • Layla M. Nassir;Mouayed H.Z. Al-Toki;Nadhim M. Faleh;Hussein Alwan Khudhair;Mamoon A.A. Al-Jaafari;Raad M. Fenjan
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.1-8
    • /
    • 2024
  • Transient dynamic behavior of a sandwich beam under thermal and impulsive loads has been researched in the context of higher-order beam theory. The impulse load of blast type has been enforced on the top exponent of the sandwich beam while it is in a thermal environment. The core of the sandwich beam is cellular with auxetic rectangular pattern, whereas the layers have been built with the incorporation of graphene oxide powder (GOP) and are micromechanically introduced through Halpin-Tsai formulization. Governing equations for the sandwich beam have been solved through inverse Laplace transform style for obtaining the dynamical deflections. The connection of beam deflections on temperature variability, GOP quantity, pulse load situation and core relative density has been surveyed in detail.

TAPINS: A THERMAL-HYDRAULIC SYSTEM CODE FOR TRANSIENT ANALYSIS OF A FULLY-PASSIVE INTEGRAL PWR

  • Lee, Yeon-Gun;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.439-458
    • /
    • 2013
  • REX-10 is a fully-passive small modular reactor in which the coolant flow is driven by natural circulation, the RCS is pressurized by a steam-gas pressurizer, and the decay heat is removed by the PRHRS. To confirm design decisions and analyze the transient responses of an integral PWR such as REX-10, a thermal-hydraulic system code named TAPINS (Thermal-hydraulic Analysis Program for INtegral reactor System) is developed in this study. Based on a one-dimensional four-equation drift-flux model, TAPINS incorporates mathematical models for the core, the helical-coil steam generator, and the steam-gas pressurizer. The system of difference equations derived from the semi-implicit finite-difference scheme is numerically solved by the Newton Block Gauss Seidel (NBGS) method. TAPINS is characterized by applicability to transients with non-equilibrium effects, better prediction of the transient behavior of a pressurizer containing non-condensable gas, and code assessment by using the experimental data from the autonomous integral effect tests in the RTF (REX-10 Test Facility). Details on the hydrodynamic models as well as a part of validation results that reveal the features of TAPINS are presented in this paper.

Performance evaluation of the Floating Absorber for Safety at Transient (FAST) in the innovative Sodium-cooled Fast Reactor (iSFR) under a single control rod withdrawal accident

  • Lee, Seongmin;Jeong, Yong Hoon
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1110-1119
    • /
    • 2020
  • The Floating Absorber for Safety at Transient (FAST) is a safety device used in the innovative Sodium-cooled Fast Reactor (iSFR). The FAST insert negative reactivity under transient or accident conditions. However, behavior of the FAST is still unclear under transient conditions. Therefore, the existing Floating Absorber for Safety at Transient Analysis Code (FASTAC) is improved to analyze the FAST movement by considering the reactivity and temperature distribution within the reactor core. The current FAST system is simulated under a single control rod withdrawal accident condition. In this investigation, the reactor thermal power does not return to its initial thermal power even if the FAST inserts negative reactivity. Only a 9 K of coolant temperature margin, in the hottest fuel assembly at EOL, can lead to unnecessary insertion of the negative reactivity. On the other hand, the FASTs cannot contribute to controlling the reactivity when normalized radial power is less than 0.889 at BOL and 0.972 at EOL. These simulation results suggest that the current FAST design needs to be optimized depending on its installed location. Meanwhile, the FAST system keeps the fuel, cladding and coolant temperatures below their limit temperatures with given conditions.

Heat transfer characteristics of redan structure in large-scale test facility STELLA-2

  • Yoon, Jung;Lee, Jewhan;Kim, Hyungmo;Lee, Yong-Bum;Eoh, Jaehyuk
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1109-1118
    • /
    • 2021
  • The construction of STELLA-2 facility is on-going to demonstrate the safety system of PGSFR and to provide comprehensive understanding of transient behavior under DBEs. Considering that most events are single-phase natural circulation flow with slow transient, STELLA-2 was designed with reduced-height of 1/5 length scale. The ratio of volume to surface area in the vessel can relatively increase resulting in excessive heat transfer. Therefore, a steady-state thermal-hydraulic analysis was performed and the effect of design change to reduce the heat transfer through redan was investigated. The heat transfer through single wall redan in STELLA-2 was 3% of the core power, comparable to 1% of the core power in PGSFR. By applying the insulated redan, about 70% of decrease effect was observed. The effect on transient behavior was also evaluated. The conclusion of this study was directly applied to the STELLA-2 design and the modified version is under construction.

비정상 열 하중을 받는 이질재료의 다중 크랙 문제 (Multi-Crack Problems for Non-homogeneous Material Subjected to Unsteady Thermal Load)

  • 김귀섭
    • 한국항공운항학회지
    • /
    • 제19권1호
    • /
    • pp.15-23
    • /
    • 2011
  • The purpose of this paper is to investigate the time behavior of a multiple crack problems. It is assumed that the medium contains cracks perpendicular to the crack surfaces, that the thermo-mechanical properties are continuous functions of the thickness coordinate. we use the laminated composite plate model to simulate the material non-homogeneity. By utilizing the Laplace transform and Fourier transform techniques, the multiple crack problems in the non-homogeneous medium is formulated. Singular integral equations are derived and solved to investigate the multiple crack problems. As a numerical illustration, transient thermal stress intensity factors(TSIFs) for a functionally graded material plate subjected to sudden heating on its boundary are provided. The variation in the TSIFs due to the change in material gradient and the crack position is studied.

화재시 콘크리트의 열특성계수가 비정상 열전달해석에 미치는 영향 (An Effectiveness of Temperature-Dependency Thermal Properties in Transient Thermal Analysis of Concrete Structures Exposed to Fire)

  • 이재영;한병찬;김재환;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.11-14
    • /
    • 2008
  • This paper is currently being conducted to develop a nonlinear finite element analysis methods for predicting the structural behavior of reinforced concrete structures, exposed to fire. The changes in thermal parameters are discussed from the point of view of changes of structure and chemical composition due to the high temperature exposure. Although, this study considers codes standard fire for reinforced concrete frame, any other time-temperature relationship can be easily incorporated.

  • PDF

가열로 내 슬랩의 온도 예측을 위한 2차원 열전달 모델 (2D Heat Transfer Model for the Prediction of Temperature of Slab in a Direct-Fired Reheating Furnace)

  • 이동은;박해두;김만영
    • 대한기계학회논문집B
    • /
    • 제30권10호
    • /
    • pp.950-956
    • /
    • 2006
  • A mathematical heat transfer model for the prediction of heat flux on the slab surface and temperature distribution in the slab has been developed by considering the thermal radiation in the furnace and transient conduction governing equations in the slab, respectively. The furnace is modeled as radiating medium with spatially varying temperature and constant absorption coefficient. The slab is moved with constant speed through non-firing, charging, preheating, heating, and soaking zones in the furnace. Radiative heat flux which is calculated from the radiative heat exchange within the furnace modeled using the FVM by considering the effect of furnace wall, slab, and combustion gases is applied as the boundary condition of the transient conduction equation of the slab. Heat transfer characteristics and temperature behavior of the slab is investigated by changing such parameters as absorption coefficient and emissivity of the slab. Comparison with the experimental work shows that the present heat transfer model works well for the prediction of thermal behavior of the slab in the reheating furnace.

연속주조 몰드의 구조해석 (Structural Analysis of Continuous Casting Mold)

  • 원종진;이종선;홍석주
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.104-110
    • /
    • 2001
  • The objective of this study is structural analysis of continuous casting mold. A two-dimensional finite element model was developed to compute the temperature distribution, thermal stress and thermal strain behavior for continuous casting mold. Structural analysis was made using thermal analysis result, utilizing transient analysis of ANSYS. This structural analysis results, many variables such as casting speed, cooling condition film coefficient, convection and load condition are considered.

  • PDF

비함침 초전도마그네트의 과도안정성 (Transient Stability in Dry-winding Superconducting Magnets)

  • 김석범;석산돈사;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.89-91
    • /
    • 1996
  • In dry-winding(unfilled) superconducting magnets, the behavior of liquid helium occupying the extremely small void space within the winding is contributed as a primary factor for transient stability of magnets. Therefore, numerical experiments have been carried out concerning the influences of transient heat transfer of liquid helium ocupying the void space in the winding and thermal properties of insulation at the conductor surface on the transient stability of magnets, by using three-dimensional finite element method(FEM). In this paper, we are going to consider three different cases for heat transfer characteristics of liquid helium to observe the influences of the rest of liquid helium in void space within the winding on the transient stability.

  • PDF