원전 밀림관 열성층의 3 차원 수치해석 (3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant)

  • 김영종;김만원;고은미
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성 (Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines)

  • 심서현;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

임펄스전류에 의한 매설지선의 과도임피던스특성에 대한 모의해석 (Simulated Analysis for the Transient Impedance Behaviors of Counterpoises Subjected to the Impulsive Currents)

  • 조정현;이복희
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1861-1868
    • /
    • 2009
  • A ground electrode subjected to lightning surge current shows the transient impedance behaviors. The ground electrode for protection against lightning should be evaluated in view of the transient grounding impedance and conventional grounding impedance, not ground resistance. The transient impedance characteristics of ground electrodes are influenced by the shape of ground electrode and the soil characteristics, as well as the waveform of lightning surge current. In order to propose a simulation method of analyzing the transient impedance characteristics of the grounding system in practical use, this paper suggests a theoretical analysis method of distributed parameter circuit model to simulate the transient impedance characteristics of counterpoise subjected to lightning surge current. EMTP and Matlab programs were employed to compute the transient grounding impedances of three counterpoises with different lengths. As a consequence, the simulated results using the proposed distributed parameter circuit model are in good agreement with the measured results.

전력계통의 전자과도현상에 관한 연구 (A Study on the Electromagnetic Transients in A Power System)

  • 김경철;강창원;이일무
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

지중송배전계통에서 과도상태시 공통접지의 영향 분석 (Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems)

  • 임광식;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.

서지전류에 대한 과도접지임피던스의 특성 (Characteristics of Transient Grounding Impedance under Surge Currents)

  • 이덕희;박종순
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권11호
    • /
    • pp.717-723
    • /
    • 1999
  • The transient characteristics of grounding systems play a major role in the protection of power equipments, electronic circuits and info-communication facilities against surges which arise from lightning or ground faults. Electronic devices are very weak against lightning surges injected from grounding systems and can be damaged. The malfunction and damage of electronic circuits bring about bad operation performances, a lot of economical losses, and etc. Therefore, in order to obtain the effective protection measure of electronic devices from overvoltages and lightning surges, the analysis of the transient grounding impedances in essential. One of this work is to examine the transient behaviors of grounding impedances under steplike currents for various grounding systems. And the other of this work is to evaluate the transient behaviors of a grid with rods under impulse currents and to investigate the effect of grounding lead wire. Transient grounding impedances of a grid with rods under impulse current waves have been measured as a parameter of the length of the grounding leads. Z-t, Z-i and V-i curves of transient grounding impedance under impulse current waveforms have been measured and analyzed. It was found that the grounding impedance gives the inductive, resistive and capacitive aspects under steplike current. Transient grounding impedance characteristics were very different with shapes, geometries of ground electrodes. Also, they were dependent on the waveform and magnitude of impulse current.

  • PDF

Surge Phenomena Analytically Predicted in a Multi-stage Axial Flow Compressor System in the Reduced-Speed Zone

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권3호
    • /
    • pp.110-124
    • /
    • 2014
  • Surge phenomena in the zone of reduced speeds in a system of a nine-stage axial flow compressor coupled with ducts were studied analytically by use of a surge transient simulation code. Main results are as follows. (1) Expansion of apparently stable, non-surge working area of the pressure vs. flow field beyond the initial stage-stall line was predicted by the code in the lower speed region. The area proved analytically to be caused by significantly mismatched stage-working conditions, particularly with the front stages deep in the rotating stall branch of the characteristics, as was already known in situ and in steady-state calculations also. (2) Surge frequencies were found to increase for decreasing compressor speeds as far as the particular compressor system was concerned. (3) The tendency was found to be explained by a newly introduced volume-modified reduced surge frequency. It suggests that the surge frequency is related intimately with the process of emptying and filling of air into the delivery volume. (4) The upstream range of movement of the fluid mass having once passed through the compressor in surge was found to reduce toward the lower speeds, which could have caused additionally the increase in surge frequency. (5) The concept of the volume-modified reduced surge frequency was able to explain, though qualitatively at present, the behaviors of the area-pressure ratio parameter for the stall stagnation boundary proposed earlier by the author.

22.9kV 수전설비에서 측정된 과도과전압의 특성 (Features of Transient Overvoltages Observed at 22.9kV Consumer's Substation)

  • 심해섭;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.52-59
    • /
    • 2014
  • The aims of this paper are to characterize the transient overvoltages(TOVs) and to evaluate the risk occurring at 22.9kV consumer's substation. The measurements of lightning- and switching-caused TOVs were made during Mar. 2013 and Feb. 2014. As a consequence, 47 events of TOVs were recorded and 4 of them were higher than the input voltage envelope(IVE) of the information technology industry council(ITI) curve. The measured TOVs are characterized by longer front times and longer durations compared to the $1.2/50{\mu}s$ standard impulse voltage waveform, and some of them represent bipolar waves with lower oscillation frequencies. It suggests that the test of non-standard impulse voltage waveforms is needed for effective risk assessments of power apparatus. Lightning- and switching-caused TOVs exceeding IVE of ITI curve are induced at the secondary of 22.9kV potential transformer(PT). We may, therefore, conclude that the surge protection devices should be applied at the secondary of PT and the surge absorbers should be installed at the primary of VCB or PT. The results presented in this paper could be useful to design the reasonable insulation coordination for 22.9kV consumer's substation.

Development of a Simulation Method of Surge Transient Flow Phenomena in a Multistage Axial Flow Compressor and Duct System

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.189-199
    • /
    • 2013
  • A practical method of surge simulation in a system of a high-pressure-ratio multistage axial flow compressor and ducts, named SRGTRAN, is described about the principal procedures and the details. The code is constructed on the basis of one-dimensional stage-by-stage modeling and application of fundamental equations of mass, momentum, and energy. An example of analytical result on surge behaviors is included as an experimental verification. It will enable to examine the transient flow phenomena caused by possible compressor surges and their influences on the system components in plant systems including high-pressure-ratio axial compressors or gas turbines.

EMTP를 이용한 ESS가 연계된 배전계통에서 직격뢰 발생 시 계통 및 ESS 측의 서지 해석 (Analysis of Surge in Distribution System and ESS due to Direct Lightning in Distribution System with ESS using EMTP)

  • 서훈철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.47-53
    • /
    • 2015
  • The study concerning about the grid connection of the large-capacity energy storage system(ESS) is increasing. However, the transient study such as lightning or switching surge necessarily occurred at power system with ESS has been hardly performed. Therefore, this paper performs the analysis of lightning surge in distribution system with ESS using electromagnetic transient program(EMTP). The battery model in Matlab/Simulink is modeled by EMTP, which is the specialized software for power system transient study. Also, the bi-directional power electronics for interconnection of the battery and distribution system are modeled by EMTP. When the lightning is occurred at interconnection point of ESS, this paper simulates the existence of ESS and operation conditions of ESS and analyzes the surge in distribution system and ESS according to the various conditions.