• Title/Summary/Keyword: transient state

Search Result 1,623, Processing Time 0.028 seconds

Transient Heat Flux Evaluation of Underwear for Protective Clothing using Sweating Manikin (발한 마네킹을 이용한 보호복용 언더웨어의 동적(Transient) 열류량 평가)

  • Park, Hye-Jun;Kim, Hyun-Jung;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.157-165
    • /
    • 2008
  • Transient thermal response of five types of underwear(cotton jersey, wool jersey, nylon jersey, cotton mesh and polyester mesh) for a protective coverall is evaluated using a sweating thermal manikin. Experimental protocol for transient thermal response of the sweating thermal manikin was also proposed. As results, it was found that steady state thermal response from sweating thermal manikin was not sensitive enough to evaluate thermal comfort of the experimental garments. However, when half time is used as an index of the heat flux change in transient thermal response, difference was found among underwear materials. Half time of cotton was the shortest and heat transfer of cotton was the fastest followed by polyester mesh, cotton jersey, nylon jersey and wool jersey. Dynamic thermal response of wool underwear was quite different from that of cotton underwear. Wool shows quite less heat flow at the initial stage, however, moisture permeability of wool was higher than cotton at the later stage. It was difficult to distinguish surface temperature difference visually using thermogram taken right before the completion of dry and wet test in steady state thermal response.

Transient thermal stresses of orthotropic functionally graded thick strip due to nonuniform heat supply

  • Ootao, Yoshihiro;Tanigawa, Yoshinobu
    • Structural Engineering and Mechanics
    • /
    • v.20 no.5
    • /
    • pp.559-573
    • /
    • 2005
  • This paper is concerned with the theoretical treatment of transient thermal stresses involving an orthotropic functionally graded thick strip due to nonuniform heat supply in the width direction. The thermal and thermoelastic constants of the strip are assumed to possess orthotropy and vary exponentially in the thickness direction. The transient two-dimensional temperature is analyzed by the methods of Laplace and finite sine transformations. We obtain the exact solution for the simply supported strip under the state of plane strain. Some numerical results for the temperature change, the displacement and the stress distributions are shown in figures. Furthermore, the influence of the orthotropy and nonhomogeneity of the material is investigated.

NUPEC BFBT SUBCHANNEL VOID DISTRIBUTION ANALYSIS USING THE MATRA AND MARS CODES

  • Hwang, Dae-Hyun;Jeong, Jae-Jun;Chung, Bub-Dong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.295-306
    • /
    • 2009
  • The subchannel grade void distributions in the NUPEC (Nuclear Power Engineering Corporation) BFBT (BWR Full-Size Fine-Mesh Bundle Tests) facility were evaluated with the subchannel analysis code MATRA and the system code MARS. Fifteen test series from five different test bundles were selected for an analysis of the steady-state subchannel void distributions. Two transient cases, a turbine trip without a bypass as a typical power transient and a re-circulation pump trip as a flow transient, were also chosen for this analysis. It was found that the steady-state void distributions calculated by both the MATRA and MARS codes coincided well with the measured data in the range of thermodynamic qualities from 5% to 25%. The results of the transient calculations were also similar and were highly feasible. However, the computational aspects of the two codes were clearly different.

A comparison of transient electromagnetic analysis and experiment result of Limeted angle torque motor (Limeted angle torgue motor의 전자기 과도해석 및 실험 결과의 비교)

  • Kim, Yong-Hoon;Kwon, Soon-O;Lee, Suwoong;Jang, Seung-Gyo;Kim, Young-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.898-899
    • /
    • 2015
  • This paper present a transient experiment to verify the performance of limited angle torque motor(LATM) designed using electromagnetic transient analysis. LATM requires access to the transitional state to the torque performance evaluation. Because LATM moves the rotor using a magnetic torque generated by the interaction of the permanent magnet and the armature winding. A separate control is not applied, it is switched on at the same time under the conditions that the current applied to the armature winding. It was compared to the transient analysis of the experimental data of LATM for the verification of approach method in the transitional state.

  • PDF

Analysis and Estimation of the Transient Thermal Characteristics of OF Cable systems (OF 케이블 계통 과도상태 열특성 해석 및 평가)

  • Kang, Ji-Won;Lee, Dong-Il;Jung, Chae-Kyun;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.10
    • /
    • pp.487-495
    • /
    • 2005
  • This paper reviews the characteristic of thermal and temperature of oil field cable in transient state such as grounding fault and lightning surge. For analysis in various conditions, many actual underground power cable systems are modeled using ATP. These results are applied for the examination of temperature increase when the single line to ground fault by the breakdown of insulation part and hitting of lightning surge are occurred. The inner part temperature of OF cable is analysed according to the various kinds of cable using the thermal model of transient state. The temperature increase of sheath and crossbonded lead bv fault current is also analysed using IEC 60949.

Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions (그리드/연계선 사고 시 풍력발전단지의 응동 분석)

  • Lee, Hye-Won;Kim, Yeon-Hee;Zheng, Tai-Ying;Lee, Sang-Cheol;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

Aspect of Naked Infinitives of English Perceptual Reports (지각동사 원형부정사 보문의 상의 분석과 학습 도모)

  • 김선희
    • Korean Journal of English Language and Linguistics
    • /
    • v.2 no.4
    • /
    • pp.519-536
    • /
    • 2002
  • This paper is to provide an analysis of the aspectual nature of naked infinitives(NIs) of English perceptual reports. Higginbotham(1983) proposes that only ‘active’ or ‘transient’ verbs can be used as NIs of English perceptual reports, but ‘state’ verbs cannot. This is called “confinement to the active or transient”. But there will be one problem when NIs of English perceptual reports are negatives. This is why the meaning of negative NIs of English perceptual reports may be static, which isn't in line with “confinement to the active or transient”. There are similar problems with ‘state’ NIs of English perceptual reports. In this paper some of these problems can be solved with the “Event Structure” of Pustejovsky(1991). According to Pustejovsky(1991), ‘process’ and ‘transition’ verbs have sub-eventual individuation units, but state verbs have no such units. It is the units that make it possible for ‘process’ and ‘transition’ to be perceived. As a result ‘process’ and ‘transition’ verbs are suitable for NIs of English perceptual reports. Nevertheless, there are still some problems unsolved. Moreover some state verbs are grammatically used as NIs of English perceptual reports. This paper proposes that these state verbs have “potentiality of transition”, and the potentiality comes from only the combination of the two parts of the complement - the subject and the naked infinitive. And the potentiality causes the “Event Structure” of Pustejovsky(1991) to be modified. And this modification makes it possible for us to explain aspect of NIs of English Perceptual Reports. It is concluded with some implication for Korean learners of English as a Foreign Language.

  • PDF

Time-resolved Anisotropy Study on the Excited-State Intramolecular Proton Transfer of 1-Hydroxyanthraquinone

  • Choi, Jun-Rye;Jeoung, Sae-Chae;Cho, Dae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.11
    • /
    • pp.1675-1679
    • /
    • 2003
  • The photodynamics of excited-state intramolecular proton transfer reaction of 1-hydroxyanthraquinone (1-HAQ) and 1-deuterioanthraquinone was investigated in toluene with time-resolved emission and femtosecond transient transmittance techniques at room temperature. The temporal profiles of transient transmittance of 1-HAQ could be well described with multi-decaying time constants. The ultrafast time constant within ca. 260 fs reflects the dynamics of proton transfer. The decay component of 2 ps is assigned to an additional proton translocation process induced by the intramolecular vibrational relaxation, whereas the decay component of 18 ps is assigned to the vibrational cooling process, while the long component (200 ps) can be explained in terms of the relaxation from excited-state keto-tautomer to its ground state. Time-resolved anisotropy decay dynamics and isotope effects on the photodynamics reveals that the ESIPT from enol-tautomer to keto-one of 1-HAQ is barrierless reaction and coupled to a vibrational relaxation process.

Boundary Element Analysis of Thermal Stress Intensity Factors for Cusp Crack in Transient State (천이상태에 있는 커스프균열에 대한 열응력세기계수의 경계요소 해석)

  • 이강용;홍정균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1700-1710
    • /
    • 1992
  • The boundary element method is applied to determine thermal stress intensity factors for a cusp crack in transient state. In the steady temperature field, numerical values of thermal stress intensity factors for a Grifith crack and a symmetric lip cusp crack in a finite body are in good agreement within .+-. 5% with the previous solutions. In transient state, the numerical values of thermal stress intensity factors for the Griffith crack are also in good agreement with the pervious solutions. In both steady and transient states, those for the symmetric lip cusp crack with the crack surface insulated or fixed to the constant temperature are calculates for various effective crack lengths, configuration parameters and uniform heat flow angles. The variations of the thermal boundary conditions of the crack surface have a effect on stress intensity factors. The signs on the values of thermal stress intensity factors can be changed in time variation.

Hotelling T2 Index Based PCA Method for Fault Detection in Transient State Processes (과도상태에서의 고장검출을 위한 Hotelling T2 Index 기반의 PCA 기법)

  • Asghar, Furqan;Talha, Muhammad;Kim, Se-Yoon;Kim, SungHo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.276-280
    • /
    • 2016
  • Due to the increasing interest in safety and consistent product quality over a past few decades, demand for effective quality monitoring and safe operation in the modern industry has propelled research into statistical based fault detection and diagnosis methods. This paper describes the application of Hotelling $T^2$ index based Principal Component Analysis (PCA) method for fault detection and diagnosis in industrial processes. Multivariate statistical process control techniques are now widely used for performance monitoring and fault detection. Conventional methods such as PCA are suitable only for steady state processes. These conventional projection methods causes false alarms or missing data for the systems with transient values of processes. These issues significantly compromise the reliability of the monitoring systems. In this paper, a reliable method is used to overcome false alarms occur due to varying process conditions and missing data problems in transient states. This monitoring method is implemented and validated experimentally along with matlab. Experimental results proved the credibility of this fault detection method for both the steady state and transient operations.