• Title/Summary/Keyword: transient gain control

Search Result 115, Processing Time 0.021 seconds

Diminution of Current Measurement Error in Vector Controlled AC Motor Drives

  • Jung Han-Su;Kim Jang-Mok;Kim Cheul-U;Choi Cheol;Jung Tae-Uk
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.151-159
    • /
    • 2005
  • The errors generated from current measurement paths are inevitable, and they can be divided into two categories: offset error and scaling error. The current data including these errors cause periodic speed ripples which are one and two times the stator electrical frequency respectively. Since these undesirable ripples bring about harmful influences to motor driving systems, a compensation algorithm must be introduced to the control algorithm of the motor drive. In this paper, a new compensation algorithm is proposed. The signal of the integrator output of the d-axis current regulator is chosen and processed to compensate for the current measurement errors. Usually the d-axis current command is zero or constant to acquire the maximum torque or unity power factor in the ac drive system, and the output of the d-axis current regulator is nearly zero or constant as well. If the stator currents include the offset and scaling errors, the respective motor speed produces a ripple related to one and two times the stator electrical frequency, and the signal of the integrator output of the d-axis current regulator also produces the ripple as the motor speed does. The compensation of the current measurement errors is easily implemented to smooth the signal of the integrator output of the d-axis current regulator by subtracting the DC offset value or rescaling the gain of the hall sensor. Therefore, the proposed algorithm has several features: the robustness in the variation of the mechanical parameters, the application of the steady and transient state, the ease of implementation, and less computation time. The MATLAB simulation and experimental results are shown in order to verify the validity of the proposed current compensating algorithm.

Research on a Development of Power System Analysis Software Considering User Convenience (사용자 편의성을 고려한 전력계통 해석 프로그램 개발 연구)

  • Ko, Baekkyeong;Song, Jiyoung;Han, Sangwook;Lee, Jaegul;Shin, Jeonghoon;An, Youngho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.31-39
    • /
    • 2016
  • Power system engineers use power systems solution programs such as PSS/E, DSATool, Power World simulators for power system analysis. In this reason, KEPCO has begun to develop independent power system program, KW-PSS(KEPCO World Power system Solution) since 2002 and KW-PSS ver2.0 development was completed in 2011. However, it did not have much better functions compared with other programs. Therefore, we focused on the development of the practical and specialized functions. Consequently, PAZ(Power system AnalyZer) ver3.0 has been developed and it realized a differentiation than previous version. In other words, previous version focused on the basic function of power system analysis, PAZ ver3.0 has implemented many automated functions for power system operators were driven maximize operational efficiency. The unique feature of the implementation is as follows : Automated check for exceeding the breaker capacity, Scheduled outage automation, Control-file wizard for various voltage stability analysis, Scenario-based multiple transient stability analysis and Auto calculation of transmission line impedance. As shown in these functions, Those functions provide to use power system analysis easily by automation and simplification for power system engineers. We will secure national expertise through PAZ ver3.0. In addition it will be able to gain competitive edge through the steady development in the world market.

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF

A Capacitorless Low-Dropout Regulator With Enhanced Response Time (응답 시간을 향상 시킨 외부 커패시터가 없는 Low-Dropout 레귤레이터 회로)

  • Yeo, Jae-Jin;Roh, Jeong-Jin
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.506-513
    • /
    • 2015
  • In this paper, an output-capacitorless, low-dropout (LDO) regulator is designed, which consumes $4.5{\mu}A$ quiescent current. Proposed LDO regulator is realized using two amplifier for good load regulation and fast response time, which provide high gain, high bandwidth, and high slew rate. In addition, a one-shot current boosting circuit is added for current control to charge and discharge the parasitic capacitance at the pass transistor gate. As a result, response time is improved during load-current transition. The designed circuit is implemented through a $0.11-{\mu}m$ CMOS process. We experimentally verify output voltage fluctuation of 260mV and recovery time of $0.8{\mu}s$ at maximum load current 200mA.

Subchronic Toxicity of a Combined Preparation of Ticlopidine and Giekgo Biloba Extract Orally Administered to Rats for 30 Days

  • Kim, Sung Y.;Yim, Hye K.;Yoon, Mi Y.;Kim, Sang K.;Lee, Ja Y.;Oh, Soo J.;Kim, Hye S.;Kang, Sung A.;Kim, Young C.
    • Toxicological Research
    • /
    • v.14 no.4
    • /
    • pp.547-555
    • /
    • 1998
  • The subchronic toxicity of a combined preparation of ticlopidine and ginkgo biloba extract (EGb 761) mixed in a ratio of 10: 4 was examined in male and female Sprague-Dawley rats. Rats were treated with the test substance at a dose of 52 mg/kg, 156 mg/kg, or 467 mg/kg intragastrically for 30 consecutive days. Control rats were treated with vehicle only. Each group consisted of 10 rats. No death or abnormal clinical signs were observed throughout the administration period. A transient decrease in body weight gain and food intake was observed in the rats treated with the high dose (467 mg/kg), which was recovered to normal in a week. There were no drug-related differences in urinalysis and hematological results. A significant increase in serum total cholesterol and total protein was observed in both sexes of the rats treated with a dose of 467 mg/kg daily, but all the other values obtained in serum chemistry appeared to be within normal range. A dose dependent increase in liver weight was observed in both male and female rats. Relative kidney weight was also increased in the high dose groups. There was no gross pathological finding at terminal sacrifice. Microscopic histopathological examination did not show any lesion in terms of correlation with administration of the test substance. The results suggest that under the conditions employed in this study no observable effect level (NOEL) of the test substance be 52 mg/kg/day.

  • PDF