• Title/Summary/Keyword: transient dynamic response

Search Result 347, Processing Time 0.024 seconds

Load Analysis of the FuelCell/Battery Hybrid Power System (연료전지 축전지 하이브리드 동력원의 접속 특성 분석)

  • Lee, Bong-Do;Lee, Won-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3081-3083
    • /
    • 2000
  • Fuel cell/battery hybrid power systems were studied to develop high efficient zero-emission fuel cell electric vehicles, Fuel cells were used as an auxiliary energy source and batteries were used as a transient power source. The fuel cell system is used to supply the average power demand. Dynamic response of the hybrid systems was simulated using PSPICE program and also tested experimentally, The results can be used to design the interface module and to determine the power requirement between the fuel cell unit and the battery pack.

  • PDF

Transient analysis of monopile foundations partially embedded in liquefied soil

  • Barari, Amin;Bayat, Mehdi;Saadati, Meysam;Ibsen, Lars Bo;Vabbersgaard, Lars Andersen
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.257-282
    • /
    • 2015
  • In this study, the authors present a coupled fluid-structures-seabed interaction analysis of a monopile type of wind turbine foundations in liquefiable soils. A two dimensional analysis is performed with a nonlinear stiffness degradation model incorporated in the finite difference program Fast Lagrangian Analysis of Continua (FLAC), which captured the fundamental mechanisms of the monopiles in saturated granular soil. The effects of inertia and the kinematic flow of soil are investigated separately, to highlight the importance of considering the combined effect of these phenomena on the seismic design of offshore monopiles. Different seismic loads, such as those experienced in the Kobe, Santa Cruz, Loma Prieta, Kocaeli, and Morgan Hill earthquakes, are analyzed. The pore water pressure development, relative displacements, soil skeleton deformation and monopile bending moment are obtained for different predominant frequencies and peak accelerations. The findings are verified with results in the liter.

A Study of the Effective Transformation of Dynamic Loads into Equivalent Static Loads using System Reduction Methods (효율적인 등가정하중 변환을 위한 축소기법과의 연동에 관한 연구)

  • Kim, Eui-Young;Cho, Maeng-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.175-178
    • /
    • 2010
  • 동하중의 영향을 받는 구조물의 효율적인 구조 해석 및 최적화 수행을 위해 동하중을 등가정하중으로 변환하는 방법이 요구된다. 이 때 적절한 자유도를 선정하여 등가정하중을 부여하는 것이 중요하다. 기존방법에서는 시스템 축소기법을 통해 일정 개수 이상의 주자유도를 선택하여 등가정하중을 부여하고 그 결과 변위가 동하중 하에서의 변위와 같도록 하였다. 그러나 보수적인 결과를 얻기 위한 제한 조건의 지배적인 성격으로 인하여 등가정하중 하에서의 변위가 지나치게 크게 나타나 그 효율성이 떨어지게 되었다. 본 연구에서는 등가정하중의 변환에 있어서 효율성을 높이는 방안을 제안한다. 제안기법은 보수적 결과를 얻는 범위 내에서 과도응답해석 결과와의 오차를 크게 줄일 수 있다. 수치예제를 통해 제안기법의 결과를 기존 기법의 결과와 비교해본다.

  • PDF

Fuzzy Control of Servo System by manipulate membership function (멤버쉽함수의 조정에 의한 Servo System의 Fuzzy 제어)

  • 이오걸;송호신;김이곤;심영진;이준탁
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.117-122
    • /
    • 1998
  • A servo system requires faster and more accurate dynamic reponses. Generally a PD control is mainly used to obtain the precision, and in the other hand a fuzzy control to improve the transient response and to cope with the nonlinearity of systems. Recently hybrid control, which is attempted to combine the advantages of PD control and a Fuzzy control was proposed, but this technique requires complicate design procedures. Therefore in this paper, designed on the Fuzzy controller with a various series rules, width of membership functions. And also it was showed to have the excellent adaptive performances against disturbances and the usefulness of this controller from the results of simulations.

  • PDF

Attitude Control of Helicopter Simulator System using A Hybrid GA-PID WAVENET Controller (Hybrid GA-PID WAVENET 제어기를 이용한 모형 헬리콥터 시스템의 자세 제어)

  • 박두환;지석준;이준탁
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.433-439
    • /
    • 2004
  • The Helicopter Simulator System is non-linear and complex. Futhermore, because of absence of its accurate mathematical model, it is difficult to control accurately its attitudes such as elevation angle and azimuth one. Therefore, we proposed a Hybrid GA-PID WAVENET(Genetic Algorithm Proportional Integral Derivative Wavelet Neural Network)control technique to control efficiently these angles. The proposed Hybrid GA-PID WAVENET is made through the following process. First, the WAVENET fundamental functions are defined. And their dilation and translation values are adjusted by GA to construct the optimal WAVENET controller. Secondly, the proportional, integral, and derivative gain coefficients of PR controller are tuned optimally. Finally, WAVENET controller which has a good transient characteristic and GA-PE controller which has a good steady state characteristic is adequately combined in hybrid type. Through the computer simulations, it is proved that the Hybrid GA-PE WAVENET control technique has a more excellent dynamic response than PID control technique and GA-PID one.

Design of an Output Feedback Variable Structure Control System (출력궤환 가변구조 제어계의 설계에 관한 연구)

  • 이기상;조동식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.883-892
    • /
    • 1992
  • In order to remove the assumption of full state availability which is one of the major difficulties with the practical realization of variable structure control system (VSCS), an output feedback variable structure control scheme for multivariable systems is proposed. The proposed output feedback VSCS is composed of a switching surfaces with dynamic structure and a new output feedback control input that can be constructed by using conventional output feedback control input design methodologies. With the proposed scheme, the practical realization of VSCS for the systems with unmeasurable states and for high order systems that conventional schemes cannot be applied is possible. Simulation results show that proposed scheme is a viable method to achieve the desired control performance, for example, good transient response, robustness against process parameter variations and external disturbance without measuring all the state variables.

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

Direct Power Control Scheme of Improved Command Tracking Capability for PMSG MV Wind turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.361-362
    • /
    • 2015
  • This paper proposes a Direct Power Control (DPC) scheme of improved command tracking capability for Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbines. Benchmarking is performed based on a neutral point clamped three-level back-to-back type voltage source converter. It is introduced to design the DPC modeling and propose DPC scheme of a three-level NPC (3L-NPC) converter. During the fault condition in wind farms, the proposed control scheme directly controls the generated output power to the command value from the hierarchical wind farm controller. The proposed control scheme is compared with conventional control scheme as respect to loss and thermal analysis. The DPC scheme of improved command tracking capability is confirmed through PLECS simulations. Simulation result shows that proposed control scheme achieves a much shorter transient time in a step response of generated output power. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG MV wind turbine to generate a high quality output power under grid fault condition.

  • PDF

Dynamic Characteristics of Gain-Clamped L-band EDFA with Bi-directional Pumps (양방향 펌프구조 고정이득 L-band EDFA의 과도응답 특성)

  • Kim, Ik-Sang
    • The Journal of Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.119-133
    • /
    • 2004
  • The gain-clamped EDFA has been developed to eliminate the output power change of WDM surviving channels to occur with added or dropped channels, which degrades the performance of EDM optical network. It maintains the constant gain of surviving channels when WDM channels are added or dropped in a network amplifying node. In this paper, the bi-directionally pumped gain-clamped EDFA is implemented to compensate the change of the input power by a lasing. The results show that the alsing of a short wavelength and backward propagation is the optimal condition to minimize the transient response of surviving channels in terms of the overshoot and gain saturation sue to the inhomogeneous broadening effect.

  • PDF

Design of Robust QFT Controller to Damp Low Frequency Oscillations of Power System (전력계통의 저주파 진동 억제를 위한 강인하 QFT 제어기 설계)

  • 정형환;이정필;김상효;정문규;안병철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.833-845
    • /
    • 2001
  • Quantitative Feedback Theory(QFT) has been used to design a robust power system stabilizer(PSS) to improve transient and dynamic stabilities of a power system. This design technique is basically accomplished in frequency domain. The most important feature of QFT is that it is able to deal with the design problem of complicated uncertain plants. A basic idea in QFT design is the translation of closed-loop frequency-domain specifications into Nichols chart domains specifying the allowable range of the nominal open-loop response and then to design a controller by using the gain-phase loop shaping technique. This paper introduces a new algorithm to compute QFT bounds more efficiently. The propose QFT design method ensures a satisfactory performance of the PSS under a wide range of power system operating conditions.

  • PDF