• 제목/요약/키워드: transformers

검색결과 1,167건 처리시간 0.024초

코호넨 특징 대응을 이용한 변압기 고장 인식 및 해석 (Transformer Fault Recognition and Interpretation Using Kohonen Feature Mapping)

  • 윤용한;김재철;최도혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.864-866
    • /
    • 1997
  • This paper presents fault recognition and interpretation in power transformers using dissolved gas analysis embedded Kohonen feature mapping. The imprecision of gas ratio analysis in dissolved gas analysis are managed by mapping in accordance with learning of Kohonen neural network. To verify the effectiveness of the proposed system, it has been tested by the historical gas records to power transformers of Korea Electric Power Corporation. More appropriate fault types can support the maintenance personnels to increase the disgnostic performance for fault of power transformers.

  • PDF

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 김홍래;임용배
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.94-99
    • /
    • 2005
  • 본 논문은 수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 방법을 제시하고 있다. 이 방법은 건전 시료의 온도 분포와 가속열화실험에 의해 층간 단락된 고장시료의 온도 분포 비교를 통해 얻어진 결과이다. 분석에 활용된 온도분포는 적외선 열화상 시스템에 의해 취득되었고, 가속 열화시험에는 Arrhenius 방정식이 적용되었다. 제안된 방법은 몰드변압기 고장을 검출하는데 유용할 것이다.

Losses in Power Distribution Transformers

  • Ketkaew, Chaliew;Philphud, Mana;Sungthong, Tossapol;Rachawong, Wiriya;Kalong, Putchong;Noohawm, Onurai;Rerkpreedapong, Dulpichet
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.144-148
    • /
    • 2015
  • The paper presents the estimation of power losses in distribution transformer of Provincial Electricity Authority (PEA) distribution system at Muang district of Suphanburi province in Thailand. Data of 416 power distribution transformers composed of transformer (kVA), load current, no load loss and full load loss which were used for calculating energy losses. It was found that the total energy loss of all transformers is approximately 1,756,380 kWh/year.

잔류자속에 무관한 전류보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식 (A Current Differential Relaying Algorithm for Power Transformers Using an Advanced Compensation Algorithm of CTs)

  • 강용철;임의재;윤재성;김은숙;원성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.314-316
    • /
    • 2003
  • To prevent maloperation during magnetic inrush and over-excitation, a current differential relay for power transformers uses harmonic current based restraining or blocking scheme; it also uses dual slope characteristics to prevent maloperation for an external fault with CT saturation. This paper proposes a current differential relaying algorithm for power transformers with an advanced compensation algorithm for the secondary current of CTs. The comparative study was conducted with and without the compensating algorithm. The algorithm can reduce the operating time of the relay in the case of an internal fault and improve security for external faults.

  • PDF

가스분석을 이용한 변압기의 이상진단 알고리즘 연구 (A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

전자기력에 의해 유도된 변압기의 진동 해석을 위한 자왜 현상 모델링 (Magnetostriction Modeling for the Analysis of Electromagnetically Induced Vibration of Transformers)

  • 유승열;이준신;이욱륜;노명규
    • 한국정밀공학회지
    • /
    • 제25권1호
    • /
    • pp.108-114
    • /
    • 2008
  • Recently, there have been several instances that the nuclear power plants were shut down due to the mechanical faults in the main transformer of the plants. These mechanical faults are primarily originated from the electromagnetically induced mechanical vibrations. Magnetostriction is identified to be the main cause of the mechanical vibration after analyzing the vibration data of the main transformers in nuclear power plants. In this study, we derived a mathematical model of the magnetostriction based on the Jiles-Atherton hysteresis model. The validity of the model is checked by matching the simulations with the experimental observations. The magnetostriction model used in this study will be the first step toward developing a design tool far the transformers that have minimal mechanical vibrations and are robust to mechanical faults.

두 개의 변압기를 이용한 새로운 소프트 스위칭 방식의 DC-DC 컨버터 (A New Soft Switching DC-DC Converter using Two Transformers)

  • 이달우;안태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.444-449
    • /
    • 2005
  • This paper proposes the new soft switching DC-DC converter. We reported the experimental results of the new soft switching DC-DC converter. The proposed converter is to resonate between the leakage inductance of the transformer and the parasitic capacitances of the main switches for zero voltage switching. The voltage stresses of the two switches are the input voltage, it can improve the efficiency and a reduced height used two transformers. Theoretical analysis of the converter along with experimental results is provided. Finally, a 3.3V/20A prototype converter operation at 100kHz is built and experimental waveform verifies the analysis.

Application of Dielectric Spectroscopy Measurements for Estimating Moisture Content in Power Transformers

  • Ekanayake, Chandima;Gubanski, Stanislaw M.;Fernando, M.A.R.M.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.81-89
    • /
    • 2004
  • Frequency Domain Spectroscopy (FDS) measurements were performed on pressboard samples containing different moisture contents and on insulation system of power transformers. The results were used for evaluating sensitivity of the so-called X - Y model, which is applied for estimating moisture content in transformer insulation using the results of FDS measurements. Based on the observations of this analysis a simplified model, called X model, was introduced in which the presence of spacers in transformer insulation has been neglected. Finally, reliability of the X model was assessed by comparing estimates of moisture contents based on FDS measurements on field installed power transformers with moisture contents obtained from chemical analyses of their oil samples.

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

주상변압기의 열화진단을 위한 원격측정 (The Deterioration Diagnosis of pole Transformer using Remote Measurement)

  • 송현선;이상돈
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 논문에서 제안한 주상변압기 열화진단 장치는 활선 상태에서 변압기 외함온도, 2차전류 및 누설전류 등을 측정하고, 지정값 이상의 상태가 발생하면 변압기 관리자에게 유선 및 이동통신기를 통하여 자동통보함으로써 사고를 사전에 예방할 수 있다. 또한 무선데이터통신을 이용하여 수집된 정보를 분석하고 각 상별 전류분포, 이용률 및 온도변화 추이를 그래프로 나타냄으로서 각 상별 부하의 불평형 정도와 변압기의 열화 추이 상태를 파악할 수 있다. 실계통 실험을 통하여 제안한 주상 변압기 열화 진단 장치의 효용성을 입증하였다.