• Title/Summary/Keyword: transformer-coupled

Search Result 133, Processing Time 0.027 seconds

Research on the Modeling of Non-contact Transformer (비접촉 변압기의 모델링에 관한 연구)

  • Ryu, Myung-Hyo;Cha, Honn-Yong;Baek, Ju-Won;Yoo, Dong-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.511-513
    • /
    • 2005
  • In this paper, the electrical characteristics of the non-contact transformer is presented using conventional coupled inductor theory. In high power applications, the non-contact transformer is so bulky and heavy that it poses some maintenance problems. Therefore it should be divided into some light transformer modules. This paper shows the analytic method of how to measure the parameters of the multiple connected non-contact transformer The analytical results are verified through measurement.

  • PDF

Calculation of Inrush Current of a Transformer using FEM (유한요소법에 의한 변압기의 돌입전류 계산)

  • 이준호;이기식
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1999
  • The inrush current of transformer can flow when the overvoltage caused by surge or external faults is applied. In this paper, an algorithm for the calculation of this inruch current is proposed. The capacitances of windings are precalculated by using 3 dimensional FEM and are appended to circuit of the transformer. And transient characteristics of the transformer are analyzed by axisymmetric FEM which is coupled magnetic field of transformer and circuit of transformer. When a transformer encounters abnormal voltage, using the proposed method, internal magnetic field of transformer, voltages and currents of windings are calculated.

  • PDF

A Novel Quasi-Resonant ZCS-PFM DC-DC Switching Regulator with Loosely-Coupled Flyback Inductors

  • Chu E.H.;Chandhaket S.;Moisseev S.;Hiraki E.;Nakaoka M.;Kifune H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.266-270
    • /
    • 2001
  • This paper presents a novel topological prototype of voltage source series quasi-resonant zero current soft-switching pulse frequency modulated dc-dc power converter circuit using IGBTs which incorporates a high-frequency flyback transformer link. Its steady-state operating principle is described on the basis of simulation analysis, along with the open loop controlled power regulation characteristics of the multi-functional coupled inductors linked dc-dc power converter operating under a principle of zero current soft switching commutation.

  • PDF

Global Simulation for $CF_4$ Discharge in Transformer Coupled Plasma Source (평판형 유도결합 플라즈마 장치의 $CF_4$ 방전에 대한 Global Simulation)

  • Kwon, Deuk-Chul;Yoo, D.H.;Kim, S.S.;Yoon, N.S.;Kim, J.H.;Shin, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1757-1759
    • /
    • 2002
  • Global simulator for $CF_4$ discharge in transformer coupled plasma (TCP) source is developed and simulations arc performed under various conditions. The developed simulator is based on a set of space averaged fluid equations for electrons, positive ions, neutrals and radicals of $CF_4$ plasma. And the used absorbed power by electrons is calculated by a 2-dimensional heating model[1].

  • PDF

A Simplified Unified Model for Predicting the Dielectrophoretic Aactivity of Magnetic Nanoparticles Aimed at Enhancing the Dielectric Characteristics of Transformer Oil

  • Lee, Jong-Cheol;Jeon, Hong-Pil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.431.2-431.2
    • /
    • 2014
  • The dielectric breakdown voltage (DBV) is a measure of an insulating fluids ability to withstand a high electric field stress without breaking down. Conventionally, the presence of water or particulate matter in a dielectric fluid comprises the liquid's breakdown strength. However, the addition of magnetic nanoparticles (MNPs) in the base oil can increase the dielectric breakdown voltage of the fluid reversely, if the condition of the added particles in the fluid is in balance with that of keeping down the initiation and propagation of electrical streamers. In this study, we developed a mathematical model by a set of coupled, nonlinear equations using the COMSOL multiphysics finite element simulation suite and calculated the dielectrophoretic activity of magnetic nanoparticles suspended in the presence of electric field, which is the behavior responsible for enhancing the dielectric characteristics of transformer oil, in order to examine how the activity differ in a transformer oil-based magnetic fluid.

  • PDF

Numerical Analysis and Design of Moving Contactless High Power Transformer

  • Lee, Dong-Su;Jang, Dong-Uk;Kim, Hyung-Chul;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.423-426
    • /
    • 2011
  • This paper presents numerical analysis and design of high power contactless transformer with a large air-gap for moving on a guided linear track which is appropriate for high-speed train or MAGLEV. The system has the typical characteristics of large leakage inductance, small magnetizing inductance, and low coupling coefficients giving rise to lower power transfer efficiency, which have been compensated by the purposely-designed contactless transformer coupled with the resonant converter modulating with high switching frequency. In particular, the best model selected from the generated six design candidates has been applied for 3D Finite Element Analysis (FEA) investigating on iron loss to evaluate the overall system efficiency.

Zero-Voltage and Zero-Current Switching Interleaved Two-Switch Forward Converter

  • Chu, Enhui;Bao, Jianqun;Song, Qi;Zhang, Yang;Xie, Haolin;Chen, Zhifang;Zhou, Yue
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1413-1428
    • /
    • 2019
  • In this paper, a novel zero-voltage and zero-current switching (ZVZCS) interleaved two switch forward converter is proposed. By using a coupled-inductor-type smoothing filter, a snubber capacitor, the parallel capacitance of the leading switches and the transformer parasitic inductance, the proposed converter can realize soft-switching for the main power switches. This converter can effectively reduce the primary circulating current loss by using the coupled inductor and the snubber capacitor. Furthermore, this converter can reduce the reverse recovery loss, parasitic ringing and transient voltage stress in the secondary rectifier diodes caused by the leakage inductors of the transformer and the coupled inductance. The operation principle and steady state characteristics of the converter are analyzed according to the equivalent circuits in different operation modes. The practical effectiveness of the proposed converter was is illustrated by simulation and experimental results via a 500W, 100 kHz prototype using the power MOSFET.

Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer (식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

AC TO AC Direct Voltage Conversion Using A Solid State Transformer

  • Um, Keehong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.5 no.1
    • /
    • pp.6-8
    • /
    • 2013
  • In this paper, we present an intelligent digital controller circuit which can be applied to automatic voltage regulation. The proposed solid state transformer with Pspice simulation model shows that our approach is very efficient and produces the desirable output. It is comparable to an ordinary magnetic coupled autotransformer.

Piezoelectric Characteristics of Pb(Mnsub 1/3Nb 23)Osub 3-Pb(Zr, Ti)Osub 3 Ceramics with $CeO_2$ Impurity for the Piezoelectric Transformer (Cerium Oxide 첨가에 따른 압전트랜스포머용 $Pb(Mn_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3$ 세라믹의 압전특성)

  • Ryu, Ju-Hyeon;Seo, Seong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.611-615
    • /
    • 1999
  • Piezoelectric properties of PMN-PZT ceramics with $CeO_2$ impurity were investigated. Mechanical quality factor, $Q_m$ of 1792, 1285 and the electromechanical coupling coefficient, $k_p$ of 0.52, 0.54 were obtained from the specimen with 0.25 and 0.5 mole % $CeO_2$ respectively. Curie temperature was decreased with the addition of $CeO_2$ while the electric coercive field was proportional to the amount of impurity. Based on the system ceramics with 0.5 mole % cerium oxide, a Rosen type piezoelectric transformer was fabricated and tested. Voltage step-up ratios of 230 and 13 were obtained from the transformer at no load and $100 k\Omega$ resistance, respectively. Experimental results showed a potential of the transformer for the practical use coupled with the expected strength increase by the grain size refinement.

  • PDF