• Title/Summary/Keyword: transformer design

Search Result 895, Processing Time 0.028 seconds

A Design Method for Dynamic Selection of SOA Services (SOA 서비스의 동적 선택 설계 기법)

  • Bae, Jeong-Seop;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.2
    • /
    • pp.91-104
    • /
    • 2008
  • Service-Oriented Computing (SOC) is the development method that published services are selected and composed at runtime to deliver the expected functionality to service clients. SOC should get maximum benefits not only supporting business agility but also reducing the development time. Services are selected and composed at runtime to improve the benefits. However, current programming language, SOC platforms, business process modeling language, and tools support either manual selection or static binding of published services. There is a limitation on reconfiguring and redeploying the business process to deliver the expected services to each client. Therefore, dynamic selection is needed for composing appropriate services to service clients in a quick and flexible manner. In this paper, we propose Dynamic Selection Handler (DSH) on ESB. we present a design method of Dynamic Selection Handler which consists of four components; Invocation Listener, Service Selector, Service Binder and Interface Transformer. We apply appropriate design patterns for each component to maximize reusability of components. Finally, we describe a case study that shows the feasibility of DSH on ESB.

Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump (제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석)

  • Yoon, Jun Seong;Kwon, Oh Kyung;Cha, Dong An;Bae, Kyung Jin;Kim, In Gwan;Kim, Min Soo;Park, Chan Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

Design of a High Power Three-Phase ZVS Push-Pull Converter (대전력 3상 ZVS 푸쉬풀 컨버터 설계)

  • Park, Jun-Sung;Lee, Sang-Won;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.209-218
    • /
    • 2011
  • In low voltage high current applications such as fuel cells the current-fed DC-DC converter which has small ripple current and turn ratio is more efficient. In the applications larger than 5kW the conventional single-phase current-fed converter based on full-bridge, half-bridge or push-pull topologies has high current burden of devices such as switches, and the selection and optimized design of the devices are not easy. In this paper a three-phase active-clamped current-fed push-pull DC-DC converter suitable for high power high step-up applications is proposed. The proposed converter has reduced current burden and is suitable for wide input voltage applications due to the use of whole duty cycle range. Design methods of main components including three-phase high frequency transformers are provided, and the validity and performance of the proposed converter are proved from a 5kW prototype.

Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter (Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계)

  • Baek, Seung-Hyuk;Kim, Sungmin;Lee, Jaehong;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

A High Efficiency ZVS PWM Asymmetrical Half Bridge Converter for Plasma Display Panel Sustaining Power Modules

  • Han Sang-Kyoo;Moon Gun-Woo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • A high efficiency ZVS PWM asymmetrical half bridge converter for a plasma display panel (PDP) sustaining power modules is proposed in this paper. To achieve the ZVS of power switches for the wide load range, a small additional inductor L/sub 1kg/, which also acts as an output filter inductor, is serially inserted into the transformer's primary side. At that point, to solve the problem of ringing in the secondary rectifier caused by L/sub 1kg/, the proposed circuit employs a structure without the output filter inductor, which helps the voltages across rectifier diodes to be clamped at the output voltage. Therefore, no dissipative RC (resistor capacitor) snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. In addition, since it has no large output inductor filter, the asymmetrical half bridge converter features a simpler structure, lower cost, less mass, and lighter weight. In addition, since all energy stored in L/sub 1kg/ is transferred to the output side, the circulating energy problem can be effectively solved. The operational principle, theoretical analysis, and design considerations are presented. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 425W, 385Vdc/170Vdc prototype are presented.

Design and Analysis of High Frequency High Power Density. High Voltage Pulse Transformer for Travel Wave Tube(TWT) High Voltage Power Supply (진행파관 고전압전원공급기의 고주파수, 고밀도, 고전압 펄스변압기의 설계 및 해석)

  • Kim, S.C.;Jung, S.H.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1043-1045
    • /
    • 2002
  • 고전압 전원공급기를 고 밀도로 제작하기 위하여 고 주파수 동작을 시켜야 한다. 이에 따라 전원 공급기에서 최대의 부피를 차지하는 부품인 변압기는 원하는 주파수에서 최소의 부피로 충분한 전력을 수용하면서 완벽한 펄스재현을 하여야 한다. 고전압 전원공급기는 풀-브릿지 DC/DC 컨버트로 구성되어 있으며 스윗칭 주파수는 100 kHz 이다. 변압기는 일차권선이 1개이며 이차 권선은 4개로 구성된다 일차전압은 250 Vdc, 이차 권선 각각의 출력은 520 Vrms이다. 변압의 이차 권선은 배 전압 회로를 이용하여 승압 후 각각을 직렬로 연결하여 -4,100 VDC와 -2,050 VDC를 만들어 TWT(Travel Wave Tube)의 케소드 및 콜렉트에 공급한다. 이 변압기는 100 kHz 펄스로 동작하고 최대부피가 400$cm^3$이하가 되어야 한다. 본 논문에서는 이러한 변압기의 설계 방법 및 최소 온도상승을 위한 적절한 동작 자속밀도의 선택에 대하여 기술하고 변압기의 누설 인덕턴스, 분포 케페시턴스, 공진 주파수에 대하여 설계치 및 실험치를 비교 평가하였다.

  • PDF

The Electric Characteristics of the Thermal Aged Insulation-Paper with Moisture Content on the Transformer (변압기 절연지의 수분함량 및 열화에 따른 전기적 특성 연구)

  • Kim, Pil-Hwan;Kim, Ju-Han;Lee, Byung-Sung;Lee, Won-Yeong;Kim, Do-Young;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1909-1911
    • /
    • 2004
  • It is caused that insulation paper, which had got a lot of thermal stress by over-load after installation, should have been deteriorated in electrical and mechanical characteristics. Beside, insulation material is decreased the insulating property and accelerated aging of them in case of dielectric loss when transformers are manufactured with some moisture or transformers would have been them because of moisture-permeation, Therefore, in this study we experienced the influence of moisture content in case of the thermal aged insulation paper. we have measured tan ${\delta}$ and breakdown voltage in the ratio of paper' moisture content before the aging and then taken the same tests again after insulation paper thermally accelerating-aged. There is a purpose to gain data for a life-design and to establish aging mechanism in order to continuously study life expectancy of the insulation paper.

  • PDF

Development of 3.6 MW, 4 ${\mu}s$, 200 pps Pulse Modulator for a High power magnetron (고출력 마그네트론 구동용 3.6 MW, 4 ${\mu}s$, 200 pps 펄스모듈레이터 개발)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKang, W.;Lee, H.K.;Bae, Y.S.;Lee, K.T.;Son, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1778-1780
    • /
    • 2004
  • Microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the reliability of operation in the beginning of plasma formation and non-inductive current drive for long time steady state operation with maintaining MHD stability, respectively. LHCD demands 5 GHz of frequency and consists of c-band waveguide, 4-port circuitor, dry dummy load, dual directional coupler, E-bend, arc detector. Our system is a lineup type pulse modulator that has 45 kV of output pulse voltage, 90 A of pulse current, 4 us of pulse width. 1:4 step-up pulse transformer, 7 stages of PFN and thyratron tube (E2V, CX1191D) are used in this modulator. The purpose of this paper is to show the modulator design and experimental result.

  • PDF

Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System

  • Guna Sekar, T.;Anita, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2015
  • This paper presents a new technique for enhancing power quality by reducing harmonics in the neutral conductor. Three-Phase Four-Wire (3P4W) system is commonly used where single and three phase loads are connected to Point of Common Coupling (PCC). Due to unbalance loads, the 3P4W distribution system becomes unbalance and current flows in the neutral conductor. If loads are non-linear, then the harmonic content of current will flow in neutral conductor. The neutral current that may flow towards transformer neutral point is compensated by using a series active filter. In order to reduce the harmonic content, the series active filter is connected in series with the neutral conductor by which neutral and phase current harmonics are reduced significantly. In this paper, solar PV based inverter circuit is proposed for compensating neutral current harmonics. The simulation is carried out in MATLAB/SIMULINK and also an experimental setup is developed to verify the effectiveness of the proposed method.

A Bidirectional Hybrid Switching Full-Bridge Converter with Active Clamp Circuit for V2G Applications (V2G 응용을 위한 능동클램프 회로를 가진 양방향 하이브리드 스위칭 풀브리지 컨버터)

  • Vuand, Hai-Nam;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.335-336
    • /
    • 2016
  • This paper introduces a bidirectional full-bridge converter with new active damp structure. The proposed active damp circuit can damp the oscillating voltage across the rectifier diodes with a smaller voltage stress of the damping capacitor and eliminate the circulating current. In addition, the proposed converter can achieve additional advantages such as nearly ZCS switching for leading-leg switches and no recovery current for rectifier-bridge by the suitable design of the damp capacitor to resonate with leakage inductor. Since the ZVS is achieved for both leading-leg and lagging-leg switches by the magnetizing current of the transformer, it can be achieved regardless of the load variation. A 3.3 kW prototype converter is implemented for vehicle-to-grid (V2G) application and the advantages of the proposed converter are verified by the experiments. The maximum efficiencies of 98.2% and 97.6% have been achieved for the buck mode and boost mode operation, respectively.

  • PDF