• 제목/요약/키워드: transfer robot

검색결과 188건 처리시간 0.024초

손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스 (Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture)

  • 장익규
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권3호
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

임상병리검사를 위한 모바일 에이전트 기반의 바이오로봇 시스템 개발 (Development of BioRobot System Based on Mobile Agent for Clinical Laboratory)

  • 최병준;진성문;신승훈;구자춘;김민철;김진현;손웅희;안기탁;정완균;최혁렬
    • 로봇학회논문지
    • /
    • 제2권4호
    • /
    • pp.317-326
    • /
    • 2007
  • Recently, robotic automation in clinical laboratory becomes of keen interest as a fusion of bio and robotic technology. In this paper, we present a new robotic platform for clinical tests suitable for small or medium sized laboratories using mobile robots. The mobile robot called Mobile Agent is designed as transfer system of blood samples, reagents, microplates, and any instruments. Also, the developed mobile agent can perform diverse tests simultaneously based on its cooperative and distributed ability. The driving circuits for the mobile agent are embedded in the robot, and each mobile agent communicates with other agents by using Bluetooth communication. The RFID system is used to recognize patient information. Also, the magnetic hall sensor is embedded to remove and compensate the cumulated error of locomotion at the bottom of mobile agent. The proposed mobile agent can be easily used for various applications because it is designed to be compatible with general software development tools. The Mobile agents are manufactured, and feasibility of the robot and localization of the agents using magnetic hall sensor are validated by preliminary experiments.

  • PDF

LQR 기법을 이용한 로봇다리의 다중입력 유압시스템 제어에 관한 연구 (A Study on the Control of Multi-Input Hydraulic System for Robot Leg using LQR Technique)

  • 유삼현;임수철
    • 한국군사과학기술학회지
    • /
    • 제12권4호
    • /
    • pp.540-547
    • /
    • 2009
  • In the near future, military robots are likely to be substituted for military personnel in the field of battle. The power system of a legged robot is considerably more complex than the one used for a land vehicle because of the coordination and stability issues due to the large number of degree of freedom. In this paper, a servovalve-piston combination system for a straight-line motion of robot leg is modeled as three degree of freedom based on double inputs and single output transfer function. The output is the displacement of piston from neutral. The inputs are valve displacement from neutral and arbitrary load force in this system. LQR(Linear Quadratic Regulator) technique is applied in order to achieve robust stability and fast responses of the system. The Kalman filter loop, rejection of disturbance and noise, riccati equation, filter gain matrix, and frequency domain equality are analyzed and designed.

제어데이터 중복전송기법에 관한 연구 (The Research about a Control Data Duplication Transmission Technique)

  • 이영주;강순덕
    • 정보학연구
    • /
    • 제9권4호
    • /
    • pp.57-63
    • /
    • 2006
  • The intelligent elder brother groove network robot service the new broadband presence line is conversionce application service. Robot control data transmission hazard UDP packet of the remote control data which stands duplication necessary to transmit. TCP the error ratio to be high qualitative recording transmission pattern it of the transmission unit and is irregular the distance is distant to show and also the transmission lag is visible increases. The recording packet drop whose UDP degree error ratio will be high is frequent and does not arrive packet little by little increases is a possibility of knowing in the transmission unit. The technique which it proposes with traffic pattern of the transmission unit is visible the transfer characteristic of the same shape from 1% packet error ratio degree. The effective transmission technique of the robot control data which puts a base in UDP protocols was proposed from the present paper. Following research it leads and it follows the duplication transmission number of time in error rate of radio link and it was thought all that controls petty the research of the mechanism which progresses is necessary.

  • PDF

A VISION SYSTEM IN ROBOTIC WELDING

  • Absi Alfaro, S. C.
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.314-319
    • /
    • 2002
  • The Automation and Control Group at the University of Brasilia is developing an automatic welding station based on an industrial robot and a controllable welding machine. Several techniques were applied in order to improve the quality of the welding joints. This paper deals with the implementation of a laser-based computer vision system to guide the robotic manipulator during the welding process. Currently the robot is taught to follow a prescribed trajectory which is recorded a repeated over and over relying on the repeatability specification from the robot manufacturer. The objective of the computer vision system is monitoring the actual trajectory followed by the welding torch and to evaluate deviations from the desired trajectory. The position errors then being transfer to a control algorithm in order to actuate the robotic manipulator and cancel the trajectory errors. The computer vision systems consists of a CCD camera attached to the welding torch, a laser emitting diode circuit, a PC computer-based frame grabber card, and a computer vision algorithm. The laser circuit establishes a sharp luminous reference line which images are captured through the video camera. The raw image data is then digitized and stored in the frame grabber card for further processing using specifically written algorithms. These image-processing algorithms give the actual welding path, the relative position between the pieces and the required corrections. Two case studies are considered: the first is the joining of two flat metal pieces; and the second is concerned with joining a cylindrical-shape piece to a flat surface. An implementation of this computer vision system using parallel computer processing is being studied.

  • PDF

복수개 로보트의 협조에 의한 경로제어 (Coordinate control of multi-robots for the trajectory following)

  • 이혁희;서일홍;김경기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.317-320
    • /
    • 1986
  • A co-operative position control is proposed for two robot manipulators with 5 degree of freedoms to transfer an object following a specified trajectory, where each manipulator is assumed to change the posture of its end effector without releasing the object.

  • PDF

로봇 냉각을 위한 수냉식 냉각판의 열적 성능 평가 (Thermal Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 강상우;이석원;황규대;김서영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1864-1869
    • /
    • 2007
  • In this study, we compare thermal performance between four different types of cold plates for humanoid robot cooling. Two commercially available cold plates made of copper have different dimensions and internal flow paths: One has $20{\times}20$ $mm^2$ base area with micro-channels and the other has $62.5{\times}62.5$ $mm^2$ base area with 85 round pin-fins. And two different types of cold plates of $20{\times}20$ $mm^2$ base area with 7 mm high are made of PC (polycarbonate), which aims to reduce the weight of cooling system. All cold plates are mounted on a $20{\times}20$ $mm^2$ copper block with two cartridge heaters of 30 $W/cm^2$. The overall heat transfer coefficient and thermal resistances for the liquid-cooled cold plates are obtained. The copper cold plate with micro-channels showed the best performance. Polycarbonate cold plates display fairly good thermal performance with more reduced system weight.

  • PDF

LCD 유리 이송용 복합재료 로봇 핸드의 식스 시그마 강건설계 (Six Sigma Robust Design of Composite Hand for LCD Glass Transfer Robot)

  • 남현욱
    • 대한기계학회논문집A
    • /
    • 제29권3호
    • /
    • pp.455-461
    • /
    • 2005
  • This research studied robust design of composite hand for LTR (LCD glass Transfer Robot). $1^{st}$ DOE (Design of Experiment) was conducted to find out vital few Xs. 108 experiments were performed and their results were statistically analyzed. Pareto chart analysis shows that the geometric parameters (height and width of composite beam) are more important than material parameters $(E_{1},\;E_{2})$ or stacking sequence angle. Also, the stacking sequence of mid-layer is more important than that of outer-layer. The main effect plots shows that the maximum deflection of LTR hand is minimized with increasing height, width of beam and layer thickness. $2^{nd}$ DOE was conducted to obtain RSM (Response Surface Method) equation. 25 experiments were conducted. The CCD (Central Composite Design) technique with four factors was used. The coefficient of determination $(R^{2})$ for the calculated RSM equation was 0.989. Optimum design was conducted using the RSM equation. Multi-island genetic algorithm was used to optimum design. Optimum values for beam height, beam width, layer thickness and beam length were 24.9mm, 186.6mnL 0.15mm and 2402.4mm respectively. An approximate value of 0.77mm in deflection was expected to be a maximum under the optimum conditions. Six sigma robust design was conducted to find out guideline for control range of design parameter. To acquire six sigma level reliability, the standard deviation of design parameter should be con trolled within $2{\%}$ of average design value

전기식 하지 외골격 로봇의 구동기 에너지 효율 향상을 위한 클러치 메커니즘 설계 (Design of Clutch Mechanism for Increased Actuator Energy Efficiency of Electrically Actuated Lower Extremity Exoskeleton)

  • 김호준;김완수;임동환;한창수
    • 한국정밀공학회지
    • /
    • 제33권3호
    • /
    • pp.173-181
    • /
    • 2016
  • This paper reports on the development of a roller-cam clutch mechanism. This mechanism can transfer bidirectional torque with high backdrivability, as well as increase actuation energy efficiency, in electrical exoskeleton robots. The developed mechanism was installed at the robot knee joint and unclutched during the swing phase which uses less metabolic energy, thereby functioning as a passive joint. The roller-cam clutch aimed to increase actuation energy efficiency while also producing high backdrivability by generating zero impedance for users during the swing phase. To develop the mechanism, mathematical modeling of the roller-cam clutch was conducted, with the design having more than three safety factors following optimization. Titanium (Ti-6AL-4V) material was used. Finally, modeling verification was done using ANSYS software.

비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석 (Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System)

  • 황성현;최현창;노태정;손태영;박범석
    • 대한기계학회논문집A
    • /
    • 제32권5호
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.