• 제목/요약/키워드: transfer factor

검색결과 1,599건 처리시간 0.026초

콜로게이트 열교환기와 평판형 열교환기의 열전달특성에 관한 실험적 연구 (Experimental Study on the Heat Transfer Characteristics in Corrugated and Flat Plate Type Heat Exchanger)

  • 박정훈;정용기;전충환;장영준;임혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.37-42
    • /
    • 2003
  • An experiment was performed to study heat transfer characteristics between corrugated heat exchanger and flat plate type one. While heat capacity(13.86kW) was provided constantly and the flow speed was varied from 2.8 to 17.9m/s, The temperature and the pressure drop were measured. Furthermore, Heat transfer coefficient, Colburn factor and Nusselt number were calculated using them. With increase of the flow speed for both exchangers, the coefficient and the pressure drop increased, but Colburn factor decreased. The coefficient, pressure drop and Colburn factor of the corrugated type were all higher than those of the flat one, which is due to the flow interruption with recirculation and reattachment of the corrugated type. The empirical correlations of Nusselt number were suggested for the tested two heat exchangers.

  • PDF

AHP를 활용한 기술이전 측정항목 중요도에 관한 연구 -국공립연구소 및 국립대학기술을 도입한 기업을 대상으로- (An Analysis on the Important Weight of Evaluation Items in Technology Transfer using AHP)

  • 이미숙;이태환;김진수
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.2758-2765
    • /
    • 2010
  • 최근 국공립연구소 및 국립대학에서 기업으로 기술이 이전되는 현상이 점차 증가하고 있다. 본 연구는 기업 입장에서 기술이전의 주요 평가지표를 파악하고 이 평가지표의 중요도를 AHP(Analytic Hierarchy Process)를 이용하여 파악하고자 한다. 먼저, 선행연구와 전문가 면접을 통해 기술이전과 관련된 12개의 주요 항목이 추출되었으며, 요인분석을 통해 이들 12개 항목들을 기술요인, 조직요인, 환경요인, 전략요인의 4요인으로 분류하였다. AHP 분석결과, 전략요인이 가장 중요한 요인으로, 그 하위항목인 '기술분야의 성장성'이 가장 중요한 항목으로 나타났다. 본 연구는 국공립연구소 및 국립대학의 연구자들이 다른 기업으로의 기술이전을 고려한 기술개발을 모색 시, 유용하게 이용될 수 있을 것이다.

주름형상 판형열교환기 채녈에서의 열전달 특성 수치해석적 연구 (Numerical Analysis of Heat Transfer Characteristics in Corrugated Plate Type Heat Exchanger Channel)

  • 김태용;이재용;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.588-594
    • /
    • 2001
  • The purpose of this study is to investigate the thermal and hydrodynamic characteristics of the channel in corrugated plate type heat exchangers numerically. Numerical work has been conducted using the Reynolds Stress Model(RSM) by utilizing the commercial finite-volume code, FLUENT. Based on this model, the dependence of heat transfer and friction factor on geometrical parameters have been investigated. It is found that larger corrugation angle give higher values of heat transfer coefficients and friction factors. As the reynolds number increases, the heat transfer coefficient also increases. It is also observed that the heat transfer coefficient reaches maximum while the friction factor stays relatively low at same corrugation angle. Through the analysis, it is found that the optimum corrugation angle for the heat exchanger performance exists. It is noted that the flow repulsions at the contact point of the two fluid streams make the low mixing more active for larger corrugation angle and high reynolds number.

  • PDF

난류열전달 향상을 위한 엇갈린 리브가 부착된 열전달면의 형상최적설계 (Shape Optimization of Heat Transfer Surfaces with Staggered Ribs To Enhance Thrbulent Heat Transfer)

  • 김홍민;김광용
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1351-1359
    • /
    • 2003
  • This study presents a numerical procedure to optimize shape of streamwise periodic ribs mounted on both of the principal walls to enhance turbulent heat transfer in a rectangular channel flow. The response surface method is used as an optimization technique. The optimization is based on Navier-Stokes analysis of flow and heat transfer with $k-{\varepsilon}$ turbulence model. The width-to-height ratio of a rib, rib height-to-channel height ratio and rib pitch to rib height ratio are chosen as design variables. The object function is defined as a function of heat transfer coefficient and friction drag coefficient with weighting factor. Optimum shapes of the rib have been obtained for the range of 0.02 to 0.1 of weighting factor.

Design Optimization of Pin-Fin Sharp to Enhance Heat Transfer

  • Li, Ping;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.185-190
    • /
    • 2005
  • This work presents a numerical procedure to optimize the elliptic-shaped pin fin arrays to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier Stokes analysis of flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show a reasonable agreement with the experimental data. Four variables including major axis length, minor axis length, pitch and the pin fin length nondimensionalized by duct height are chosen as design variables. The objective function is defined as a linear combination of heat transfer and friction-loss related terms with weighting factor. D-optimal design is used to reduce the data points, and, with only 28 points, reliable response surface is obtained. Optimum shapes of the pin-fin arrays have been obtained in the range from 0.0 to 0.1 of weighting factor.

  • PDF

Measurement of Heat Transfer Coefficient in Dimpled Channel: Effect of Dimple Arrangement and Channel Height

  • Lee, K.S.;Shin, S.M.;Park, S.D.;Kwak, J.S.;Kang, J.S.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.39-44
    • /
    • 2008
  • In this paper, heat transfer coefficients were measured in a channel with one side dimpled surface. The sphere type dimples were fabricated and the diameter and depth of dimple was 16mm and 4mm, respectively. Two channel heights of about 0.6 and 1.2 time of the dimple diameter, two dimple configuration were tested. The Reynolds numbers based on the channel hydraulic diameter was varied from 30000 to 50000. The improved hue detection based transient liquid crystal technique was used in the heat transfer measurement. Heat transfer measurement results showed that high heat transfer was induced downstream of dimples due to flow reattachment. Due to the flow recirculation on the upstream side in the dimple, the heat transfer coefficient was very low. As the Reynolds increased, the overall heat transfer coefficients also increased. With same dimple arrangement, the heat transfer coefficients and the thermal performance factor were higher for the lower channel height. As the distance between dimples became smaller, the overall heat transfer coefficient and the thermal performance factor were increased.

  • PDF

Associations of post-warming embryo or blastocyst development with clinical pregnancy in vitrified embryo or blastocyst transfer cycles

  • Hong, Yeon Hee;Lee, Jang Mi;Kim, Seul Ki;Youm, Hye Won;Jee, Byung Chul
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제47권2호
    • /
    • pp.140-146
    • /
    • 2020
  • Objective: To investigate whether the degree of post-warming embryo or blastocyst development is associated with clinical pregnancy in vitrified embryo or blastocyst transfer cycles. Methods: Ninety-six vitrified cleavage-stage embryos and 58 vitrified blastocyst transfer cycles were selected. All transfer cycles were performed from February 2011 to March 2019, and all vitrified embryos or blastocysts were warmed from 4 PM to 6 PM and then transferred the next morning from 9 AM to 10 AM. The scores of the cleavage-stage embryos and blastocysts were assessed at warming and at transfer using the modified Steer method and the Gardner method, respectively. The mean embryo or blastocyst score, score of the single top-quality embryo or blastocyst, and the difference in the score between warming and transfer were compared between nonpregnant and pregnant women. Results: In the cleavage-stage embryo transfer cycles, both the top-quality embryo score at transfer and the difference in the score between warming and transfer were significantly associated with clinical pregnancy. A top-quality embryo score at transfer of ≥ 60.0 (area under the curve [AUC], 0.673; 95% confidence interval [CI], 0.531-0.815) and a difference in the score between warming and transfer of ≥ 23.0 (AUC, 0.675; 95% CI, 0.514-0.835) were significant predictors of clinical pregnancy. In blastocyst transfer cycles, the top-quality blastocyst score at transfer was the only significant factor associated with clinical pregnancy. A top-quality blastocyst score at transfer of ≥ 38.3 was a significant predictor of clinical pregnancy (AUC, 0.666; 95% CI, 0.525-0.807). Conclusion: The top-quality embryo score at transfer and the degree of post-warming embryo development were associated with clinical pregnancy in vitrified cleavage-stage embryo transfer cycles. In vitrified blastocyst transfer cycles, the top-quality blastocyst score at transfer was the only significant factor affecting clinical pregnancy.

Sperm Cytosolic Factor Activation for Bovine Somatic Cell Nuclear Transfer

  • Shin, Tae-Young
    • 한국수정란이식학회지
    • /
    • 제26권3호
    • /
    • pp.171-180
    • /
    • 2011
  • In this study I report that in vitro development rates of bovine nuclear transfer embryos activated either with boar sperm cytosolic factor (SCF) or with ionomycin followed by cycloheximide (CHX) and subsequent in vivo developmental rates after embryo transfer are related to blastocyst quality as evaluated by apoptosis analysis. SCF was extracted from porcine semen then purified for post-activation injection after nuclear transfer. The optimal timing for SCF injection was determined to be at least 22 h post-IVM for parthenogenetic activation of bovine oocyies. A total of 364 oocytes were successfully enucleated and 268 (73.6%) fused and were injected with SCF. The survival rate of fused and injected embryos was 109/113 (96.5%) after 2 h. The cleavage rates of nuclear transfer embryos after 3 d of culture in the ionomycin/CHX treated group were significantly higher than those of the SCF-activated group (93.3% vs 81.7%, p<0.01, respectively). However, at 7 d and 9 d there was no significant difference between the total developmental rates to blastocyst for either treatment group. Total blastocyst cell numbers were also not significantly different between the two activation treatments (ionomycin/CHX: 149.5${\pm}$7.7 vs. SCF: 139.3${\pm}$4.4 cells). In contrast, the apoptotic levels in the SCF blastocysts were higher than those produced after the chemical treatment (28.2${\pm}$5.1% vs. 8.8${\pm}$0.6%, respectively). A total of 18 expanded or hatching blastocysts was transferred to nine synchronized recipients in each activation group; 5/9 (55.5%) and 2/9 (22.2%) were pregnant at 40 d in the ionomycin/CHX treatment and SCF activated group, respectively. However, only one went to term in the ionomycin/CHX treatment while none of the pregnancies from the SCF group were maintained by 90 d. In conclusion, these results suggest that SCF derived from different species is a limited activator to be used for activation after bovine nuclear transfer in lieu of a chemical activation protocol.

Comparison of Bioavailability and Biological Transfer Factor of Arsenic in Agricultural Soils with Different Crops

  • Oh, Se Jin;Kim, Sung Chul;Ok, Yong Sik;Oh, Seung Min;Ji, Won Hyun;Yang, Jae E.
    • 한국토양비료학회지
    • /
    • 제47권6호
    • /
    • pp.518-524
    • /
    • 2014
  • Heavy metal pollution in agricultural field near at the abandoned metal mines has been a critical issue in Korea. In particular, bioaccumulation in plants can have detrimental effect on human health. Main objective of this research was to examine arsenic (As) concentration in soil with varied extraction methods and to determine bioaccumulation and biological transfer factor in different crops. Results showed that bioaccumulation ratio of As for total contents in soil was ordered leafy and stem vegetables (1.19%) > fruit bearing vegetables (0.79%) > pulses (0.40%) > root vegetables (0.36%) with different crop species. Among 6 different extraction methods, all of extraction methods showed high correlation ($R^2=0.87-0.97$) except DTPA ($R^2=0.25$) when comparing As concentration in soil extracted with different extractants and As concentration in each crops. Calculated biological transfer factor was ranged 0.002-0.018 depending on crop species. Overall, concentration of As in crops can be varied and best management practice for minimizing bioaccumulation of As should be considered depending on crop species.

마이크로핀관에서의 냉매 R-22, R-407C의 응축전열특성에 관한 연구 (Condensation heat transfer characteristics of R-22 and R-407C in micro-fin tubes)

  • 노건상
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.50-56
    • /
    • 2008
  • Experimental results for forced convection condensation of Refrigerant-22 and ternary Refrigerant-407C(HFC-32/125/134a 23/25/52 wt%) which is being considered as a substitute R-22 inside a horizontal micro-fin tube are presented. The test section was horizontal double-tube counterflow condenser with a length 4,000 mm micro-fin tube, having 8.53 mm ID, 0.2 mm fin height and 60 fins. The range of parameters of mass velocity were varied from 102.1 to 301.0 kg/(m2.s) and inlet quality 1.0. At the given experimental conditions. the average heat transfer coefficients for R-407C were lower than that for R-22 at a micro-fin tube. Over the mass velocity range tested. the PF(penalty factor) for R-22, R-407C were lower than the increasing ratio of heat transfer area by fins, and the EF(enhancement factor) for R-22, R-407C were higher than the increasing ratio of heat transfer area by fins.