• 제목/요약/키워드: transcatheter closure

검색결과 24건 처리시간 0.021초

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

  • Park, Young-A;Kim, Nam-Kyun;Park, Su-Jin;Yun, Bong-Sic;Choi, Jae-Young;Sul, Jun-Hee
    • Clinical and Experimental Pediatrics
    • /
    • 제53권12호
    • /
    • pp.1012-1017
    • /
    • 2010
  • Purpose: Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. Methods: Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in our institute. Among them, 115 weighed less than 10 kg. All of these patients underwent transcatheter closure of PDA using either COOK Detachable $Coil^{(R)}$, PFM Nit-$Occlud^{(R)}$, or Amplatzer duct $occluder^{(R)}$. A retrospective review of the treatment results and complications was performed. Results: The mean age of patients was $9.1{\pm}5.9$ months (median, 8 months), and mean weight was $7.6{\pm}1.8kg$ (median, 7.8 kg). The mean diameter of PDA was $3.2{\pm}1.4mm$ (median, 3 mm). Complete occlusion occurred in 113 patients (98%). One patient was sent to surgery because of a failed attempt at device closure, and another patient had a small residual shunt after device placement. The average mean length of hospital stay was $3.0{\pm}3.3$ days, and mean follow-up duration was $21.0{\pm}19.6$ months. There were no major complications in any of the patients. Conclusion: Transcatheter closure of PDA is considered safe and efficacious in infants weighing less than 10 kg. With sufficient experience and further effort, transcatheter closure of PDA can be accepted as the gold standard of treatment for this group of patients.

Outcomes of transcatheter closure of ductus arteriosus in infants less than 6 months of age: a single-center experience

  • Choi, Gwang-Jun;Song, Jinyoung;Kim, Yi-Seul;Lee, Heirim;Huh, June;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • 제61권12호
    • /
    • pp.397-402
    • /
    • 2018
  • Purpose: Transcatheter device closure of patent ductus arteriosus (PDA) is challenging in early infancy. We evaluated PDA closure in infants less than 6 months old. Methods: We performed a retrospective review of infants less than 6 months of age who underwent attempted transcatheter device closure in our institution since 2004. To compare clinical outcomes between age groups, infants aged 6-12 months in the same study period were reviewed. Results: A total of 22 patients underwent transcatheter PDA closure during the study period. Patient mean age was $3.3{\pm}1.5months$, and weight was $5.7{\pm}1.3kg$. The duct diameter at the narrowest point was $3.0{\pm}0.8mm$ as measured by angiography. The most common duct type was C in the Krichenko classification. Procedural success was achieved in 19 patients (86.3%). Major complications occurred in 5 patients (22.7%), including device embolization (n=1), acquired aortic coarctation (n=2), access-related vascular injury requiring surgery (n=1), and acute deterioration requiring intubation during the procedure (n=1). Two patients had minor complications (9.1%). Twenty-four infants aged 6-12 months received transcatheter device closure. The procedural success rate was 100%, and there were no major complications. The major complication rate was significantly higher in the group less than 6 months of age (P=0.045). There was a trend toward increased major complication and procedural failure rates in the younger age group (P<0.01). Conclusion: A relatively higher incidence of major complications was observed in infants less than 6 months of age. The decision regarding treatment modality should be individualized.

Percutaneous Transcatheter Closure of Congenital Ventricular Septal Defects

  • Jinyoung Song
    • Korean Circulation Journal
    • /
    • 제53권3호
    • /
    • pp.134-150
    • /
    • 2023
  • Ventricular septal defects (VSDs) are the most common kind of congenital heart disease and, if indicated, surgical closure has been accepted as a gold-standard treatment. However, as less-invasive methods are preferred, percutaneous device closure has been developed. After the first VSD closure was performed percutaneously by Lock in 1988, both techniques and devices have developed consistently. A perventricular approach for closure of muscular VSD in small patients and the closure of perimembranous VSD using off-label devices are key remarkable developments. Even though the Amplatzer membranous VSD occluder (Abbott) could not be approved for use due to the high complete atrioventricular conduction block rate, other new devices have shown good results for closure of perimembranous VSDs. However, the transcatheter technique is slightly complicated to perform, and concerns about conduction problems after VSD closure with devices remain. There have been a few reports demonstrating successful closure of subarterial-type VSDs with Amplatzer devices, but long-term issues involving aortic valve damage have not been explored yet. In conclusion, transcatheter VSD closure should be accepted as being as effective and safe as surgery but should only be performed by experienced persons and in specialized institutes because the procedure is complex and requires different techniques. To avoid serious complications, identifying appropriate patient candidates for device closure before the procedure is very important.

Emergent Surgical Intervention for Embolization of Atrial Septal Defect Closure Device

  • Kim, Young Hak;Kim, Hyuck;Kim, Sung Jin;Kang, Jeong Ho;Chung, Won-Sang;Shin, Jin-Ho;Lim, Young-Hyo
    • Journal of Chest Surgery
    • /
    • 제45권5호
    • /
    • pp.320-322
    • /
    • 2012
  • The percutaneous transcatheter closure of secundum atrial septal defect has recently become an increasingly widespread alternative to surgical closure in many centers. Although immediate, short, and intermediate term results of percutaneous transcatheter septal closure are promising, the procedure is not free from inherent complications that could be lethal. We report a case of device embolization necessitating emergent surgical retrieval.

Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure

  • Song, Jinyoung
    • Clinical and Experimental Pediatrics
    • /
    • 제57권7호
    • /
    • pp.297-303
    • /
    • 2014
  • Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important because different defect morphologies could variously impact the results. During the procedure, real-time 3D echocardiography can be used to guide an accurate closure. The safety and efficiency of transcatheter closures of atrial septal defects could be improved through the use of detailed imaging studies.

선천성 심질환에 대한 중재적 치료술의 최근 진전 (Recent advances in transcatheter treatment of congenital heart disease)

  • 최재영
    • Clinical and Experimental Pediatrics
    • /
    • 제49권9호
    • /
    • pp.917-929
    • /
    • 2006
  • Over the last several decades there has been a remarkable change in the therapeutic strategy of congenital heart disease. Development of new tools and devices, accumulations of experience, technical refinement have positively affected the outcome of interventional treatment. Many procedures including atrial septostomy, balloon valvuloplasty, balloon dilation of stenotic vessel with or without stent implantation, transcatheter occlusion of abnormal vascular structure, transcatheter closure of patent arterial duct and atrial septal defect, are now performed as routine interventional procedures in many institutes. In diverse conditions, transcatheter techniques also provide complementary and additive role in combination with surgery. Intraoperative stent implantation on stenotic vessels, perventricular device insertion, and hybrid stage 1 palliative procedure for hypoplastic left heart syndrome have been employed in high risk patients for cardiac surgery with encouraging results. Transcatheter closure of ventricular septal defect has been performed safely showing comparable result with surgery. Investigational procedures such as percutaneous valve insertion and valve repair are expected to replace the role of surgery in certain group of patients in the near future. Continuous evolvement in this field will contribute to reduce the risk and suffering from congenital heart disease, while surgery will be still remained as a gold standard for significant portion of congenital heart disease.

외상성 심실중격결손 수술 후 잔존하는 심실중격결손에 대한 중재적 심도자술을 이용한 폐쇄 (Transcatheter Closure of a Residual Shunt after Surgical Repair of Traumatic Ventricular Septal Defect)

  • 정희정;임한혁;유재현;이재환;길홍량
    • Clinical and Experimental Pediatrics
    • /
    • 제48권10호
    • /
    • pp.1143-1143
    • /
    • 2005
  • 흉부 관통상에 의해 심실중격결손이 동반된 대부분의 환자들은 내원 시 활력징후가 불안정하여 심폐소생술 및 응급 개흉술을 시행받게 되는데, 이러한 경우 심장과 흉부 손상의 위치 및 정도에 대한 자세한 검사가 이루어지지 않은 상태이므로 발견되지 않았거나 잔존하는 이상 소견들이 수술 후 검사에서 발견될 수 있고 이에 대한 재수술을 필요로 하는 경우도 있다. 심실중격결손의 심도자술을 통한 폐쇄는 수술을 대처할 수 있는 방법으로서, 특히 수술 후 잔존하는 단락의 경우 이차 수술의 위험을 피할 수 있다. 저자들은 흉부 자상에 의한 심실벽의 열창 및 심실중격결손을 수술적 방법으로 봉합한 후 잔존하는 심실중격결손을 기구($Amplatzer^{(R)}$ VSD occluder)를 이용한 중재적 심도자술로 치료한 증례를 문헌 고찰과 함께 보고한다. 심도자술 6개월 후 시행한 심초음파검사에서 잔존하는 심실 좌우 단락은 없었고, 심실 크기와 기능도 정상이었고, 현재 상태는 양호하여 정상적으로 학교생활을 하고 있다.

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • 제56권9호
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.

원통형 모양 동맥관의 경피적 폐쇄술에서의 Amplatzer Vascular Plug 의 사용 (Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus)

  • 최은영;장소익;김수진
    • Clinical and Experimental Pediatrics
    • /
    • 제52권9호
    • /
    • pp.1035-1037
    • /
    • 2009
  • 동맥관 개존증은 선천성 심질환 중 비교적 흔한 질환이며, 크기나 중등도에 상관없이 폐쇄가 필요한 질환이다. 경피적 동맥관 폐쇄술은 개흉술에 비하여 합병증의 위험이 적고 경제적으로도 바람직하며, 치료 성적도 우수하여 최근에는 표준적인 치료법으로 받아들여지고 있다. 하지만 원통형 모양의 동맥관 개존증은 흔히 사용하는 분리형 코일이나 ADO로 시술하기에는 여러 가지로 어려운 점이 많다. 저자들은 이러한 형태의 동맥관을 폐쇄하기 위하여 일반적으로 추천되는 것보다 큰 크기의 AVP를 이용하여 원통형 동맥관이 메워지도록 하는 방법을 이용함으로써, 성공적인 동맥관 개존증 폐쇄술을 시행하였기에 이를 보고하는 바이다.

Utility of 3D Echocardiography for Device Sizing During Transcatheter ASD Closure: A Comparative Study

  • Avinash Mani;Sivadasanpillai Harikrishnan;Bijulal Sasidharan;Sanjay Ganapathi;Ajit Kumar Valaparambil
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.180-187
    • /
    • 2023
  • BACKGROUND: Two-dimensional (2D) transesophageal echocardiography (TEE) is commonly used for assessing patients undergoing transcatheter atrial septal defect (ASD) device closure. 3D TEE, albeit providing high resolution en-face images of ASD, is used in only a fraction of cases. We aimed to perform a comparative analysis between 3D and 2D TEE assessment for ASD device planning. METHODS: This was a prospective, observational study conducted over a period of one year. Patients deemed suitable for device closure underwent 2D and 3D TEE at baseline. Defect characteristics, assessed separately in both modalities, were compared. Using regression analysis, we aimed to derive an equation for predicting device size using 3D TEE parameters. RESULTS: Thirty patients were included in the study, majority being females (83%). The mean age of the study population was 40.5 ± 12.05 years. Chest pain, dyspnea and palpitations were the common presenting complaints. All patients had suitable rims on 2D TEE. A good agreement was noted between 2D and 3D TEE for measured ASD diameters. 3D TEE showed that majority of defects were circular in shape (60%). The final device size used had high degree of correlation with 3D defect area and circumference. An equation was devised to predict device size using 3D defect area and circumference. The mean device size obtained from the equation was similar to the actual device size used in the study population (p = 0.31). CONCLUSIONS: Device sizing based on 3D TEE parameters alone is equally effective for transcatheter ASD closure as compared to 2D TEE.