• Title/Summary/Keyword: trace of matrix

Search Result 139, Processing Time 0.034 seconds

WEAKTYPE $L^1(R^n)$-ESTIMATE FOR CRETAIN MAXIMAL OPERATORS

  • Kim, Yong-Cheol
    • Journal of the Korean Mathematical Society
    • /
    • v.34 no.4
    • /
    • pp.1029-1036
    • /
    • 1997
  • Let ${A_t)}_{t>0}$ be a dilation group given by $A_t = exp(-P log t)$, where P is a real $n \times n$ matrix whose eigenvalues has strictly positive real part. Let $\nu$ be the trace of P and $P^*$ denote the adjoint of pp. Suppose that $K$ is a function defined on $R^n$ such that $$\mid$K(x)$\mid$ \leq k($\mid$x$\mid$_Q)$ for a bounded and decreasing function $k(t) on R_+$ satisfying $k \diamond $\mid$\cdot$\mid$_Q \in \cup_{\varepsilon >0}L^1((1 + $\mid$x$\mid$)^\varepsilon dx)$ where $Q = \int_{0}^{\infty} exp(-tP^*) exp(-tP)$ dt and the norm $$\mid$\cdot$\mid$_Q$ stands for $$\mid$x$\mid$_Q = \sqrt{}, x \in R^n$. For $f \in L^1(R^n)$, define $mf(x) = sup_{t>0}$\mid$K_t * f(x)$\mid$$ where $K_t(X) = t^{-\nu}K(A_{1/t}^* x)$. Then we show that $m$ is a bounded operator of $L^1(R^n) into L^{1, \infty}(R^n)$.

  • PDF

Analysis of Synthetic Fragrances (SFs) in Water Using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS (교반막대 추출법과 GC-MS/MS를 이용한 수중의 합성 향물질류 분석)

  • Seo, Chang-Dong;Son, Hee-Jong;Yoom, Hoon-Sik;Choi, Jin-Taek;Ryu, Dong-Choon;Kwon, Ki-Won;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.387-395
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC-MS/MS) has been developed, allowing the simultaneous multi-analyte determination of 11 synthetic fragrances (SFs) in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 10.9%). The extraction efficiencies were above 83% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~4.1 ng/L and 6.6~12.9 ng/L, respectively. The developed method offers the ability to detect 11 SFs at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 11 SFs. The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.

Determination of fatty acid methyl esters (FAME) content in aviation turbine fuel using multi-dimensional GC-MS (Multi-dimensional GC-MS를 이용한 항공터빈유의 FAME 함량 분석)

  • Youn, Ju Min;Doh, Jin Woo;Hwang, In Ha;Kim, Seong Lyong;Kang, Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.717-726
    • /
    • 2017
  • The current allowable cross-contamination level of fatty acid methyl esters (FAME) in aviation turbine fuel (AVTUR) is 50 mg/kg, due to that the presence of FAME in AVTUR can significantly impact the fuel supply system and jet engine. It has been difficult to analyze the level of FAME in AVTUR, since it is consisted of a lot of hydrocarbons. In this study, thus, a new method using multi-dimensional GC-MS (MDGC-MS) was proposed in order to determine the FAME level in AVTUR effectively. Applying to MDGC-MS with Deans switching system enabled us to detect and quantify the FAME with low carbon numbers such as those derived from coconut oil and palm kernel oil. The matrix effect of MDGC-MS method, which could shift the FAME peaks to slightly longer retention times, was reduced by 20 times compared with that of 1-dimensional GC-MS reference method. This developed method could be suitable for qualitative and quantitative analyses to determine the contamination level of trace FAME in AVTUR.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

A Study on Microstructure and Mechanical Properties of TiB2-steel Composite Fabricated by Gas Pressure Infiltration Process (가스압 함침 공정으로 제조된 TiB2-steel 금속복합재료의 미세조직 및 기계적 물성에 관한 연구)

  • Lee, Jihye;Lee, Donghyun;Cho, Seungchan;Kwon, Hansang;Lee, Sang-Kwan;Lee, Sang-Bok;Kim, Junghwan
    • Composites Research
    • /
    • v.35 no.4
    • /
    • pp.248-254
    • /
    • 2022
  • In this study, TiB2-steel composite with high-fractional TiB2 reinforcement was fabricated by gas pressure infiltration process and the microstructure analysis and compressive strength and hardness were evaluated. To elucidate the correlation between microstructure and mechanical properties for fabricated composite, after the compression test of TiB2-steel composite, the fracture surface was analyzed and the fracture behavior on compression test was predicted. As a result of the compression fracture surface analysis, interfacial failure trace between the steel matrix and the reinforcement was observed, and the interface between the steel matrix and the reinforcement was analyzed using TEM. From the result of microstructure analysis on the fabricated composite, it was confirmed that, in addition to TiB2 reinforcement and steel matrix, TiC phase and coarse (Fe,M)2B (M=Cr,Mn) phase were formed. Throughout the thermodynamic calculation, it was confirmed that TiC and (Fe,M)2B can be formed as a stable phase under the process condition. The fabricated TiB2-steel composite had a significantly increased hardness, and the compressive strength and Young's modulus were improved by 3.07 times and 1.95 times, respectively, compared to steel matrix. It seems that the coarse (Fe,M)2B (M=Cr,Mn) phase formed throughout the composite causes the deterioration of mechanical properties, and by controlling the formation of the (Fe,M)2B (M=Cr,Mn) phase, it is judged that the mechanical properties of the TiB2-steel composite can be further improved.

A Method for the Preliminary Estimation of Vertical Natural Vibations of High Speed Boats (고속선(高速船) 선체고유상하진동(船體固有上下振動)의 초기추정(初期推定) 방법(方法))

  • K.C.,Kim;H.B.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 1980
  • For the preliminary estimation of the vertical hull natural frequency, the Schlick's or Schlick-type formulae have been traditional ones and are still in common use today. Some investigators have made their efforts, based on statistical data of ships' system parameters, to extend the applicability of Schlick-type formulae to higher modes, or to utilize the Rayleigh method. For instance, the work done by Dinsenbacher et al.[5] belongs to the former and that of Nagamoto et al.[6] to the latter. In a part of his previous paper[7], the author, investigating the case of a cargo ship of medium size, suggested that provided statistically simplified curves such as trapezoid of system parameter distributions are available in hands, direct utlization of an ordinary computer program can be also an another convenient method by which we can obtain both natural frequencies and normal mode shapes. In this paper, to confirm the feasibility of the above suggestion, four high speed boats are investigated. The system parameters of them are originally given in [5]. The computer program used here is one confiled based on a calculation method derived from Myklestal-Prohl modeling of hull, transfer matrix formulation and an extended Gumbel's initial value method for solving frequency equation. The results of the investigation show that the direct calculation based on statistically oriented and reasonably assumed trapezoidal mean curves of system parameter distributions can give us natural frequencies within about 5% deviation up to several-noded modes and normal mode shapes serviceable at least up to 4- or 5-noded modes in comparision with those based on actual distributions of system parameters. For this simplified method the actual data required for input are only of ship length, displacement, total added mass, bending and shear rigidity at amidship. They are available at the early stage of design. By this method we can also easily trace variations of vibration characteristics in the course of ship design cycles.

  • PDF

Bio-Composite Materials Precursor to Chitosan in the Development of Electrochemical Sensors: A Critical Overview of Its use with Micro-Pollutants and Heavy Metals Detection

  • Sarikokba, Sarikokba;Tiwari, Diwakar;Prasad, Shailesh Kumar;Kim, Dong Jin;Choi, Suk Soon;Lee, Seung-Mok
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.237-257
    • /
    • 2020
  • The role of nano bio-composites precursor to chitosan are innumerable and are known for having different applications in various branches of physical sciences. The application to the sensor development is relatively new, where only few literature works are available to address the specific and critical analysis of nanocomposites in the subject area. The bio-composites are potential and having greater affinity towards the heavy metals and several micro-pollutants hence, perhaps are having wider implications in the low or even trace level detection of the pollutants. The nano-composites could show good selectivity and suitability for the detection of the pollutants as they are found in the complex matrix. However, the greater challenges are associated using the bio-composites, since the biomaterials are prone to be oxidized or reduced at an applied potential and found to be a hinderance for the detection of target pollutants. In addition, the materials could proceed with a series of electrochemical reactions, which could produce different by-products in analytical applications, resulting in several complex phenomena in electrochemical processes. Therefore, this review addresses critically various aspects of an evaluation of nano bio-composite materials in the electrochemical detection of heavy metals and micro-pollutants from aqueous solutions.

The Fate and Factors Determining Arsenic Mobility of Arsenic in Soil-A Review

  • Lee, Kyo Suk;Shim, Ho Young;Lee, Dong Sung;Chung, Doug Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • Arsenic which is found in several different chemical forms and oxidation states and causes acute and chronic adverse health effects is a toxic trace element widely distributed in soils and aquifers from both geologic and anthropogenic sources. Arsenic which has a mysterious ability to change color, behavior, reactivity, and toxicity has diverse chemical behavior in the natural environment. Arsenic which has stronger ability to readily change oxidation state than nitrogen and phosphorus due to a consequence of the electronic configuration of its valence orbitals with partially filled states capable of both electron donation and acceptance although the electronegativity of arsenic is greater than that of nitrogen and similar to that of phosphorus. Arsenate (V) is the thermodynamically stable form of As under aerobic condition and interacts strongly with solid matrix. However, it has been known that adsorption and oxidation reactions of arsenite (III) which is more soluble and mobile than As(V) in soils are two important factors affecting the fate and transport of arsenic in the environment. That is, the movement of As in soils and aquifers is highly dependent on the adsorption-desorption reactions in the solid phase. This article, however, focuses primarily on understanding the fate and speciation of As in soils and what fate arsenic will have after it is incorporated into soils.

Application of extraction chromatographic techniques for separation and purification of emerging radiometals 44/47Sc and 64/67Cu

  • Vyas, Chirag K.;Park, Jeong Hoon;Yang, Seung Dae
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.2 no.2
    • /
    • pp.84-95
    • /
    • 2016
  • Considerably increasing interest in using the theranostic isotopes/ isotope pairs of radiometals like $^{44/47}Sc$ and $^{64/67}Cu$ for diagnosis and/or therapeutic applications in the nuclear medicine procedures necessitates its reliable production and supply. Separation and purification of no-carrier-added (NCA) isotopes from macro quantitates of the irradiated target matrix along with other impurities is a cardinal procedure amongst several other steps involved in its production. Multitudinous methods including but not limited to liquid-liquid (solvent) extraction, extraction chromatography (EXC), ion exchange, electrodeposition and sublimation are routinely applied either solitarily or in combination for the separation and purification of radioisotopes depending on their production routes, radioisotope of interest and impurities involved. However, application of EXC though has shown promises towards the numerous separation techniques have not received much attention as far as its application prospects in the field of nuclear medicine are concerned. Advances in the recent past for application of the EXC resins in separation and purification of the several medically important radioisotopes at ultra-high purity have shown promising behavior with respect to their operation simplicity, acidic and radiolytic stability, separation efficiencies and speedy procedures with the enhanced and excellent extraction abilities. In this mini review we will be talking about the recent developments in the application and the use of EXC techniques for the separation and purification of $^{44/47}Sc$ and $^{64/67}Cu$ for medical applications. Furthermore, we will also discuss the scientific and practical aspects of EXC in the view of separation of the NCA trace amount of radionuclides.

Fundamental study of electrolyte cathode atomic discharge for development of on-line monitoring system (On-line monitoring system 개발에 관한 음극 액상 글로우 방전의 기초 연구)

  • Kim, Kyung-Mi;Woo, Young-A;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.496-501
    • /
    • 2002
  • The electrolyte cathode glow discharge (ELCAD) is a new optical system for direct determination of trace heavy metals in flowing water. ELCAD has been successfully developed for on-line monitoring of heavy metals in flowing water. The application of an atmospheric glow discharge between an electrolyte solution cathode and a platinum rod anode led to the development of stable discharge. The fundamental aspects of new plasma source have been investigated. The fundamental study of ELCAD system has been measured plasma temperature using Einstein-Boltzmann equation after searching Fe atomic emission lines. The spectrum of each elements such as Cu, Pb, Fe, Ni and Cr show only major elemental line and no ionic line possibly due to low temperature plasma source. The detection limits of each elements are also investigated. These informations show that this type of plasma may apply for monitoring of heavy metals in waste water which consists of complex matrix.