• Title/Summary/Keyword: toxic test

Search Result 775, Processing Time 0.024 seconds

Evaluation on Environmental Bio-toxicity of Industrial Wastewater (산업폐수의 생물독성 발현에 관한 연구)

  • Kim, S.H.;Cheon, S.U.;Shin, K.S.;Jung, D.I.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

Sensitivity of Daphnia magna to the Toxic Materials by the static Test (Static Test에 의한 Daphnia magna의 환경오염물질에 대한 민감성 평가)

  • 한의정;최성헌;김진일
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.101-109
    • /
    • 1994
  • Acute toxicity of heavy metals( mercury, cadmium lead, chromium and copper ), organophosphours insecticides( EPN, 2, 4- D, and parathion ), and other chemicals( arsenic, cyanide, and phenol ) to Daphnia magna was analyzed. Acute toxicity of heavy metals, organophosphours insecticides and other chemicals on Daphnia magna, LC$_{50}$ was showed 0.07-0.73mg/1, 0.22-1.94mg/t and 1.73-39.92mg/1 respectively. Daphnia magna to most of toxic chemicals was sensitive and then it seems to be useful except phenol in toxic test of water. Toxic chemicals were classified as Group 1 which had a high LC$_{50}$ value and the low increase rate of toxicity according to the increase of concentration, Group 2 which had a high LC$_{50}$ value and the high increase rate of toxicity, Group 3 which had a low LC$_{50}$ value and the low increase rate of toxicity. To Daphnia magna, lead, chromium, EPN, and parathion were included in Group 1; Mercury and copper in Group 2; Arsenic and cadmium in Group 3; Cyanide 2,4- D, and phenol in Group 4.

  • PDF

Comparison of Short-Term Toxicity Tests Based on Feeding Behavior and Temperature Control by Ceriodaphnia dubia (Ceriodaphnia dubia의 먹이섭생 기작과 온도조절에 근거한 급성독성조사법의 비교)

  • Park, Jong-Ho;Lee, Sang-Ill;Cho, Young-Oak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.48-54
    • /
    • 2004
  • Two methods, a Ceriodaphnia algal uptake suppression test (CAUST) and a new toxicity test based on temperature control (TTBTC) which are based on feeding behaviour and temperature control, respectively, were developed and compared for the adoption as the better methodology for short-term toxicity screening. As previously published by Lee et aI., (1997), the CAUST method is based on the feeding behaviour of C. dubia and requires as little as 1 hour of contact time between C. dubia neonates and toxicant. However, even though CAUST requires only 1 hour of contact time, this method still take many hours for the preparation and measurement. Before the test starts, neonate digestive tracts were cleared by feeding yeast to the daphnids, Neonates were then exposed to toxicant, followed by addition of Scenedesmus subspiatus into the bioassay vessels. Daphnids were examined under the bright-field microscope with the presence of algae (indicated by a green colored digestive tract) or the absence of algae. Uptake indicated no toxic effect, whereas, absence of uptake indicated toxic inhibition. Unlike CAUST, the newly developed method (TTBTC) is based on just temperature control for the toxicity test of C. dubia. Initially, neonates are exposed to toxicants while the temperature of water bath containing media increased to $35.5^{\circ}C$. After 1.25 hour of contact time, the number of the daphnids, either live (no toxic effect) or dead (toxic effect), is counted without the aid of any instrument. In both methods, median effective concentrations ($EC_{50}$ values) were computed based on the results over a range of dosed toxicant concentrations. It showed that TTBTC was as sensitive as the standard 48-hour acute bioassay and CAUST. TTBTC and CAUST were much more sensitive than the I-hour I.Q. test and 30-minute Microtox. This study indicates that TTBTC is an easier and more rapid toxicity test than the standard 48-hour acute bioassay and even CAUST.

Bioassays On marine Organisms: Acute Toxicity Test Of mercury, Cadmium And Copper To Arkshell, Anadara broughtonii, From Jin-Dong Bay, And To Oyster, Crassostrea gigas, From Kwang-Do Bay, South Coast Of Korea

  • Park, Joo-Suck;Kim, Hak-Gyoon
    • 한국해양학회지
    • /
    • v.13 no.1
    • /
    • pp.35-43
    • /
    • 1978
  • Short-term acute toxicity of mercury, cadmium and copper to arkshell, Anadara broughtonii, and to oyster, Crassostrea gigas, was determinedby static bioassays from 20 May to 27 June in 1977. During the observations of the opening rate of the shell mercury was the most sensitive toxicant of the three toxic substances to the test animals and caused them to close their shellvalves together after being exposed to a mercury solution for an hour during the test. Opening rate to cadmium and copper increased gradually at the higher concentration. the 96hr-LC50 values for the test animals are 4.84mg/l for mercury and 1.86mg/l for cadmium, while the 72hr-LC50 value for copper is 0.31mg/l. the death rate of oysters for cadmium showed lower than that of the mercury and copper test solutions. The 96hr-LC50 values of mercury, copper and cadmium were 1.1mg/l, 2.54mg/l and 19.5mg/l, respectively. For oysters mercury was the most toxic substance, and cadmium was the least toxic one. the medium lethal time (LT 50) value decreased gradually at higher concentration of heavy metals. The LT 50 of 2mg/l was found within 96 hours ofr copper, 104 hours for mercury and 121 hours for cadmium. The lethal threshold concentrations for 7 days were found to be about 1mg/l for mercury and copper, and 2mg/l for cadmium.

  • PDF

Ecotoxicity Assessment of Industrial Effluent in Korea (산업폐수 방류수의 생태독성 평가)

  • Oh, Kyung Taek;Kim, Ji Won;Kim, Woo Kun;Lee, Soon Ae;Yun, Hong Gil;Lee, Sung Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • Ecotoxicity assessments of 90 selected effluents of 22 industry types from 2002 to 2004 in Korea were evaluated by a toxic battery of bioassay test using fish Oryzias latipes, invertebrate Daphnia magna, algae Selenastrum capricornutum and bacteria Vibrio fischeri with the physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea. Total toxic unit (${\Sigma}TU$) of 8 industry types of 22 industry types by the toxic battery appeared in order of the value site as follows; Pigment Dye Manufacturing (${\Sigma}TU$ 217.1) > Textile and Dye (${\Sigma}TU$ 39.3) > Semiconductor Electronic Manufacturing (Small) (${\Sigma}TU$ 25.6) > Wastewater and Sewage Treatment Plants (${\Sigma}TU$ 25.4) > Coating (${\Sigma}TU$ 23.8) > Leather Skin Manufacturing (${\Sigma}TU$ 18.0) > Synthetic Resin Manufacturing (${\Sigma}TU$ 15.6) > Assemble Metal Manufacturing (${\Sigma}TU$ 10.7). Our results demonstrate that ecotoxicity assessment, by bioassay test, is effective and practical for industrial wastewater management for 90 selected effluents with the limitation of the physicochemical permit. Among 90 effluents, 9 samples failed physicochemical permit limitation and 81 passed it. In result of ecotoxicity assessment of 90 effluents by the toxic battery, 76 effluents exhibited ecotoxicity and the others did not. The physicochemical measurement items and permit concentrations on the present Water Quality Conservation Act in Korea were low related to the ecotoxicity value by the toxic battery and appeared limited for water quality management to water-ecosystem and environment-friendly management of water.

Occurrence quantity comparison of the toxic gases of the railway car's gangway materials using a Smoke Density-Chamber (철도차량용 통로연결막 재료별 독성성분의 발생량 비교)

  • Lee, Eun-Kyoung;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1533-1539
    • /
    • 2007
  • It is mainly due to the toxic gases, produced from the material combustion, threatens human body in case of urban railway car like subway which passes through underground tunnel. In the field of railway industry, fire accidents was not frequent but occurs in each country and, the causes was investigated. The advanced country established the test standard (e.g., BS, EN) to measure the toxic gases quantitatively and, have applied to enhance the fire safety of railway car. We must also follow the procedures to use gangway material for railway car as stated the Safety regulation for the urban railway car. In this study, various gangway materials(silicon, synthtic rubber, soaltapulin) are used to investigate element of toxic gases when the fire occurs. The amount of toxic gases measured from the ISO 5659 chamber using cone heater was measured and compared the results for each materials.

  • PDF

A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity (연소독성지수와 마우스 행동정시시간 비교 연구)

  • Cho, Nam-Wook;Lee, Jong-Cheon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • Casualties due to toxic smoke products have been reported as major fire damage. There are various tests in order to evaluate toxic smoke from a fire at home and abroad, and KS F 2271 as a test of the gas hazard of building finish materials has been conducted in Korea. The current test of the gas hazard exposes rodent, laboratory rat, to smoke gases to evaluate combustion gas toxicity by measuring acting time of that. this study performed a test of the gas hazard for combustible polymer material, Urethane and rubber flooring, and determined gases with the FT-IR. Quantitative results compared with standard value defined in BS6853 and toxicity index (R) was calculated. Using relative comparison with animal test and the toxicity index, We tried a variety of toxicity evaluation by correlation analysis of two tests.

Disposal of Highly Toxic Wastes by using High Temperature and High Pressure Combustor (난분해성 환경오염물질의 고온.고압연소)

  • Yoon, Jae-Kun;Hong, Ho-Yeun;Lee, Jeong-Woo;Kim, Jong-Pyo;Kang, Su-Sok
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.75-78
    • /
    • 2006
  • Disposal of highly toxic wastes like polychlorinated biphenyls (PCBs) is very difficult. These substances create a growing mountain of problematic waste that has to be disposed properly. Conventional technologies that are based on common burning(rotary kiln, ${\sim}1100^{\circ}C$) and plasma technology(${\sim}10000^{\circ}C$) do not satisfy important conditions. for example, complete combustion of the toxic waste and the price of waste disposal. The combustor like a rocket engine is operated at relatively high pressure(${\sim}15$ bar) and relatively high temperature(>$3000^{\circ}C$) that are ideal for the complete destruction of extremely toxic substances. In this study, test compound($_o-DCB$) was dissolved in kerosine with a concentration of 10%. Pure gas oxygen was used as an oxidant. Analysis showed that the destruction efficiency achieved for ${o}-DCB$ was 99.9999% or better. The results show that a combustor based on liquid propllant rocket technology is a validated tool for the disposal of highly toxic waste, and a good alternative technology when applied to the destruction of extremely toxic wastes.

  • PDF

Assessment of the Effects of Some Insecticides on Mortality of Earthworm (Eisenia fetida) (수종 살충제가 줄지렁이 치사에 미치는 영향평가)

  • Na, Young-Eun;Bang, Hae-Son;Kang, Kee-Kyung;Han, Min-Su;Ahn, Young-Joon
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.3
    • /
    • pp.289-294
    • /
    • 2005
  • The toxic effects of 12 commercially available insecticides on the earthworm, Eisenia fetida (Savigny), were evaluated using artificial soil, surface sprayed soil, immersion, and contact filter tests. The risk to earthworm was assessed by the TER (toxic exposure ratio) value, which was calculated by the formula, TER=NOEC/PEC (predicted environmental concentration). TER was 3 for methomyl SL, 20 for carbaryl WP, 20 for phosphamidon SL, 30 for imidacloprid WP, and 60 for dichlorvos EC the in artificial soil test. At recommended, the earthworm mortality to methomyl SL reached 50% in the surface sprayed soil test, 72% in the immersion test, 30% in the contact filter paper test, whereas that to imidacloprid WP reached 56, 32, and 100 respectively. As a result of the four methods, methomyl SL and imidacloprid WP would be toxic insecticides to earthworm.

The Experimental Study for the Smoke Optical Density and Toxic Gases of Sandwich Panel Insulations(Single Chamber Method) (샌드위치패널 단열재의 연기농도 및 연소독성가스에 대한 실험적 연구(연소챔버법))

  • Park, Soo-Young;Lee, Woo-Seok;Yeo, Han-Seung;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.26-32
    • /
    • 2006
  • Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.