• Title/Summary/Keyword: tower measurements

Search Result 104, Processing Time 0.026 seconds

Spatio-temporal protocol for power-efficient acquisition wireless sensors based SHM

  • Bogdanovic, Nikola;Ampeliotis, Dimitris;Berberidis, Kostas;Casciat, Fabio;Plata-Chaves, Jorge
    • Smart Structures and Systems
    • /
    • v.14 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • In this work, we address the so-called sensor reachback problem for Wireless Sensor Networks, which consists in collecting the measurements acquired by a large number of sensor nodes into a sink node which has major computational and power capabilities. Focused on applications such as Structural Health Monitoring, we propose a cooperative communication protocol that exploits the spatio-temporal correlations of the sensor measurements in order to save energy when transmitting the information to the sink node in a non-stationary environment. In addition to cooperative communications, the protocol is based on two well-studied adaptive filtering techniques, Least Mean Squares and Recursive Least Squares, which trade off computational complexity and reduction in the number of transmissions to the sink node. Finally, experiments with real acceleration measurements, obtained from the Canton Tower in China, are included to show the effectiveness of the proposed method.

Modal Parameter Estimations of Wind-Excited Structures based on a Rational Polynomial Approximation Method (유리분수함수 근사법에 기반한 풍하중을 받는 구조물의 동특성 추정)

  • Kim, Sang-Bum;Lee, Wan-Soo;Yun, Chung-Bang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.287-292
    • /
    • 2005
  • This paper presents a rational polynomial approximation method to estimate modal parameters of wind excited structures using incomplete noisy measurements of structural responses and partial measurements of wind velocities only. A stochastic model of the excitation wind force acting on the structure is estimated from partial measurements of wind velocities. Then the transfer functions of the structure are approximated as rational polynomial functions. From the poles and zeros of the estimated rational polynomial functions, the modal parameters, such as natural frequencies, damping ratios, and mode shapes are extracted. Since the frequency characteristics of wind forces acting on structures can be assumed as a smooth Gaussian process especially around the natural frequencies of the structures according to the central limit theorem (Brillinger, 1969; Yaglom, 1987), the estimated modal parameters are robust and reliable with respect to the assumed stochastic input models. To verify the proposed method, the modal parameters of a TV transmission tower excited by gust wind are estimated. Comparison study with the results of other researchers shows the efficacy of the suggested method.

  • PDF

Identification of structural displacements utilizing concurrent robotic total station and GNSS measurements

  • Pehlivan, Huseyin
    • Smart Structures and Systems
    • /
    • v.30 no.4
    • /
    • pp.411-420
    • /
    • 2022
  • Monitoring large structures is a significant issue involving public health on which new studies are constantly carried out. Although the Global Navigation Satellite System (GNSS) is the most preferable method for measuring structural displacements, total stations, one of the classical geodetic instruments, are the first devices that come to mind in cases that require complementary usage and auxiliary measurement methods. In this study, the relative displacements of the structural movements of a tower were determined using robotic total stations (RTS) and GNSS. Two GNSS receivers and two RTS observations were carried out simultaneously for 10 hours under normal weather conditions. The spectral analysis of the GNSS data was performed using fast Fourier transform (FFT), and while the dominant modal frequencies were determined, the total station data were balanced with the least-squares technique, and the position and position errors were calculated for each measurement epoch. It has been observed that low-frequency structural movements can be determined by both methods. This result shows that total station measurements are a helpful alternative method for monitoring large structures in situations where measurements are not possible due to the basic handicaps of GNSS or where it is necessary to determine displacements with short observations.

Simultaneous Measurements of Polarization and Strain under Electric Field Ferroelectric Ceramics (강유전체 세라믹스에서의 전계인가에 따른 Polarization 및 Strain의 동시 측정)

  • Park, Jae-Hwan;Hong, Guk-Seon;Park, Sun-Ja
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.221-227
    • /
    • 1996
  • 60Hz의 교류전계를 사용하는 종래의 Sawyer-Tower회로를 응용하여 0.1Hz의 직류 개념(quasi-DC)의 전계를 이용한 polarization과 strain의 동시 측정을 실시하였다. 측정의 대상으로는 강유전체로서 압전변형을 보이는 재료 중 가장 대표적인 PZT 계와 완화형 강유전체로서 전왜변형을 보이는 재료 중 가장 대표적인 PZT계와 완화형 강유전체로서 전왜변형을 보이는 재료 중 가장 대표적인 PMN계로 하였다. 0.1Hz한 주기의 전계 인가로 이력곡선을 측정할 수 있어서 시편의 발열을 크게 억제할 수 있었고 정확한 온도에서의 측정이 가능하였다. 또한 양방향 전계뿐 아니라 단방향 전계, 바이어스 전계도 인가할 수 있기 때문에 종래의 Sawyer-Tower 방법에서는 얻을 수 없는 강유전성에 관한 다양한 정보를 얻을 수 있었다. 이 방법은 또한 0.1Hz의 전계 하에서 얻을 수 없는 강유전성에 관한 다양한 정도를 얻을 수 있었다. 이 방법은 또한 0.1Hz의 전계 하에서 이력곡선이 측정되는 한 주기 동안에 시편에 부착된 스트레인 게이지를 통해 전계인가에 따른 strain 변화를 동시에 측정할 수 있기 때문에 strain과 polarization의 상관관계를 정확히 조사할 수 있다는 장점이 있다. PMN계에서 인가되는 전계의 넓은 범위에서 전왜정수 Q값을 연속적으로 구할 수 있었다.

  • PDF

Mode shape expansion with consideration of analytical modelling errors and modal measurement uncertainty

  • Chen, Hua-Peng;Tee, Kong Fah;Ni, Yi-Qing
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.485-499
    • /
    • 2012
  • Mode shape expansion is useful in structural dynamic studies such as vibration based structural health monitoring; however most existing expansion methods can not consider the modelling errors in the finite element model and the measurement uncertainty in the modal properties identified from vibration data. This paper presents a reliable approach for expanding mode shapes with consideration of both the errors in analytical model and noise in measured modal data. The proposed approach takes the perturbed force as an unknown vector that contains the discrepancies in structural parameters between the analytical model and tested structure. A regularisation algorithm based on the Tikhonov solution incorporating the L-curve criterion is adopted to reduce the influence of measurement uncertainties and to produce smooth and optimised expansion estimates in the least squares sense. The Canton Tower benchmark problem established by the Hong Kong Polytechnic University is then utilised to demonstrate the applicability of the proposed expansion approach to the actual structure. The results from the benchmark problem studies show that the proposed approach can provide reliable predictions of mode shape expansion using only limited information on the operational modal data identified from the recorded ambient vibration measurements.

Updating finite element model using dynamic perturbation method and regularization algorithm

  • Chen, Hua-Peng;Huang, Tian-Li
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.427-442
    • /
    • 2012
  • An effective approach for updating finite element model is presented which can provide reliable estimates for structural updating parameters from identified operational modal data. On the basis of the dynamic perturbation method, an exact relationship between the perturbation of structural parameters such as stiffness change and the modal properties of the tested structure is developed. An iterative solution procedure is then provided to solve for the structural updating parameters that characterise the modifications of structural parameters at element level, giving optimised solutions in the least squares sense without requiring an optimisation method. A regularization algorithm based on the Tikhonov solution incorporating the generalised cross-validation method is employed to reduce the influence of measurement errors in vibration modal data and then to produce stable and reasonable solutions for the structural updating parameters. The Canton Tower benchmark problem established by the Hong Kong Polytechnic University is employed to demonstrate the effectiveness and applicability of the proposed model updating technique. The results from the benchmark problem studies show that the proposed technique can successfully adjust the reduced finite element model of the structure using only limited number of frequencies identified from the recorded ambient vibration measurements.

The aerodynamic characteristics of twin column, high rise bridge towers

  • Ricciardelli, Francesco;Vickery, Barry J.
    • Wind and Structures
    • /
    • v.1 no.3
    • /
    • pp.225-241
    • /
    • 1998
  • The high-rise supporting towers of long-span suspension and cable-stayed bridges commonly comprise a pair of slender prisms of roughly square cross-section with a center-to-centre spacing of from perhaps 2 to 6 widths and connected by one or more cross-ties. The tower columns may have a constant spacing as common for suspension bridges or the spacing may reduce towards the top of the tower. The present paper is concerned with the aerodynamics of such towers and describes an experimental investigation of the overall aerodynamic forces acting on a pair of square cylinders in two-dimensional flow. Wind tunnel pressure measurements were carried out in smooth flow and with a longitudinal intensity of turbulence 0.10. Different angles of attack were considered between $0^{\circ}$ and $90^{\circ}$, and separations between the two columns from twice to 13 times the side width of the column. The mean values of the overall forces proved to be related to the bias introduced in the flow by the interaction between the two cylinders; the overall rms forces are related to the level of coherence between the shedding-induced forces on the two cylinders and to their phase. Plots showing the variation of the force coefficients and Strouhal number as a function of the separation, together with the force coefficients spectra and lift cross-correlation functions are presented in the paper.

A Spectropolarimetric Investigation of the Photospheric and Chromospheric Layers of Sunspots

  • Kim, Hyunnam;Solanki, Sami.K.;Lagg, Andreas;Kim, Kap-Sung;Lim, Daye;Choe, G.S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.128.2-128.2
    • /
    • 2012
  • Spectro-polarimetry is the most powerful technique for deducing the magnetic structure of the Sun. Stokes vector allow us to infer the physical conditions in the solar atmosphere prevailing during the line formation. Inversion codes are the main tool to extract this information from the Stokes spectra. This study will focus on measurements of the chromospheric He I 1083.0 nm triplet and the photospheric Si I 1082.7 nm line. A spectropolarimetric data set of sunspots, obtained with the German Vacuum Tower Telescope (VTT) at the Teide observatory on Tenerife, is analyzed using an inversion technique. We will introduce the German Vacuum Tower Telescope and the inversion code HeLix, and will show data sets that are analyzed by HeLix. Finally I made variety plots and maps for understanding photospheric and chromospheric layers of sunspots.

  • PDF

Wind characteristics of a strong typhoon in marine surface boundary layer

  • Song, Lili;Li, Q.S.;Chen, Wenchao;Qin, Peng;Huang, Haohui;He, Y.C.
    • Wind and Structures
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 2012
  • High-resolution wind data were acquired from a 100-m high offshore tower during the passage of Typhoon Hagupit in September, 2008. The meteorological tower was equipped with an ultrasonic anemometer and a number of cup anemometers at heights between 10 and 100 m. Wind characteristics of the strong typhoon, such as mean wind speed and wind direction, turbulence intensity, turbulence integral length scale, gust factor and power spectra of wind velocity, vertical profiles of mean wind speed were investigated in detail based on the wind data recorded during the strong typhoon. The measured results revealed that the wind characteristics in different stages during the typhoon varied remarkably. Through comparison with non-typhoon wind measurements, the phenomena of enhanced levels of turbulence intensity, gust factors, turbulence integral length scale and spectral magnitudes in typhoon boundary layer were observed. The monitored data and analysis results are expected to be useful for the wind-resistant design of offshore structures and buildings on seashores in typhoon-prone regions.

Conservation Treatment of Gilded bronze Sarria Reliquary Excavated from Songlim Temple Tower (송림사(松林寺) 전탑(塼塔) 출토(出土) 금동제(金銅製) 사리장치(舍利裝置)의 보존처리(保存處理))

  • Kim, Jong-oh
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.1-7
    • /
    • 2001
  • The gilded bronze Sarria reliquary(National Treasure No. 325-1) excavated from a five story tower in Songlim Temple is considered as a very important Sarria reliquary of Unified Silla Dynasty Kingdom along with glass Sarria containers excavated in package. It was found that this Sarria container was in a very weak condition in the conservation dept. of National Museum of Korea due to the wearing of the inside wood and the decay of the gilded bronze, so a conservation treatment was conducted by focusing on the prevention of further decay and wearing. Also because there is little information about Sarria reliquary, detailed investigation by means of precision actual measurements, microscopic examination and X-ray photography was carried out.