Effect of Step Height and Visual Feedback on the Lower Limb Kinematics Before and After Landing

  • Jangwhon Yoon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: Landing from a step or stairs is a basic motor skill but high incidence of lateral ankle sprain has been reported during landing with inverted foot. Objects: This study aimed to investigate the effect of landing height and visual feedback on the kinematics of landing and supporting lower limbs before and after the touch down and the ground reaction force(GRF)s. Methods: Eighteen healthy females were voluntarily participated in landing from the lower (20 cm) and the higher (40 cm) steps with and without visual feedback. To minimize the time to plan the movement, the landing side was randomly announced as a starting signal. Effects of the step height, the visual feedback, or the interaction on the landing duration, the kinematic variables and the GRFs at each landing event point were analyzed. Results: With eyes blindfolded, the knee flexion and ankle dorsiflexion on landing side significantly decreased before and after the touch down. However, there was no significant effect of landing height on the anticipatory kinematics on the landing side. After the touch down, the landings from the higher step increased the knee flexion and ankle dorsiflexion on both landing and supporting sides. From the higher steps, the vertical GRF, anterior GRF, and lateral GRF increased. No interaction between step height and visual feedback was significant. Conclusion: Step height and visual feedback affected the landing limb kinematics independently. Visual feedback affected on the landing side while step height altered the supporting side prior to the touch down. After the touch down, the step height had greater influence on the lower limb kinematics and the GRFs than the visual feedback. Findings of this study can contribute to understanding of the injury mechanisms and preventing the lateral ankle sprain.

A Study on User-Centric Force-Touch Measurement using Force-Touch Cover (포스 터치 커버를 이용한 사용자 중심적 포스 터치 측정에 관한 연구)

  • Nam, ChoonSung;Suh, Min-soo;Shin, DongRyeol
    • Journal of Internet Computing and Services
    • /
    • v.18 no.3
    • /
    • pp.37-48
    • /
    • 2017
  • Touch interface has been introduced as one of the most common input devices that are widely used in the Smart Device. Recently Force-Touch interface, a new approach of input method, having the power recognition mechanism, has been appeared in Smart industries. Force-Touching determining multiple things (the geographical and pressure values of touching point) in one touching act allows users to provide more than one input methods in a limited environments. Force-Touching Device is required different user communicational interaction than other common Smart devices because it is possible to recognize various inputs in the one act. It means that Force-Touching is only able to understand and to use the pressure sensitive values, not other Smart input methods. So, we built Force-Touch-Cover that makes typical Smart-Device to have Force-Touching interfaces. We analysis the accuracy of the Force-Touching-Cover's sensor and also assessment the changes in pressure values depending on the pressure position. Via this Paper, We propose the implement of user-oriented Force-Touching interface that is based on users' feedback as our conclusion.

Suboptimal control of arc welding process using surface temperature measurement (표면온도 측정에 의한 아크용접공정의 부최적제어)

  • 부광석;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.322-326
    • /
    • 1989
  • This paper describes design procedure of suboptimal control to minimize a performance index which is represented as sum of square output error and the heat input power in arc welding process. Heat input and temperature of a fixed point on the surface of the material are concerned as input and output of the process, repectively. The suboptimal control law considered here in is a proportional plus integral type and is implemented by using only the output variables available from sensor which is also optimally located in a fixed point w.r.t. a moving weld touch.

  • PDF

A Study on the 3-dimensional feature measurement system for OMM using multiple-sensors (멀티센서 시스템을 이용한 3차원 형상의 기상측정에 관한 연구)

  • 권양훈;윤길상;조명우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.158-163
    • /
    • 2002
  • This paper presents a multiple sensor system for rapid and high-precision coordinate data acquisition in the OMM (On-machine measurement) process. In this research, three sensors (touch probe, laser, and vision sensor) are integrated to obtain more accurate measuring results. The touch-type probe has high accuracy, but is time-consuming. Vision sensor can acquire many point data rapidly over a spatial range but its accuracy is less than other sensors. Also, it is not possible to acquire data for invisible areas. Laser sensor has medium accuracy and measuring speed among the sensors, and can acquire data for sharp or rounded edge and the features with very small holes and/or grooves. However, it has range- constraints to use because of its system structure. In this research, a new optimum sensor integration method for OMM is proposed by integrating the multiple-sensor to accomplish mote effective inspection planning. To verify the effectiveness of the proposed method, simulation and experimental works are performed, and the results are analyzed.

  • PDF

Design of Moir${\acute{e}}$- and Starburst-Free Metal Meshes for Touch Screen Panels (모아레, 스타버스트 현상이 없는 터치스크린 패널용 메탈 메쉬 설계)

  • Shin, Dong-Kyun;Park, Jong-Woon;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.1
    • /
    • pp.83-90
    • /
    • 2014
  • Using a ray tracing simulation, we have investigated the moir${\acute{e}}$ and starburst phenomena of touch screen panels (TSPs) based on opaque metallic grids (square, hexagonal, and random grids). It is demonstrated that employing a random metal mesh is the most effective way to suppress the moir${\acute{e}}$ and starburst phenomena at the same time. At high crossing angles between metal mesh of TSPs and black matrix (BM) of displays, however, a random metal mesh brings in stronger moir${\acute{e}}$ phenomenon than a square metal mesh due to point defects. Though the square metal mesh suppresses the moir${\acute{e}}$ effect substantially at high crossing angles, yet it results in the strongest starburst patterns. We have also provided the simulation scheme that can capture the moir${\acute{e}}$ and starburst patterns observed experimentally and useful design guidelines for metal grids.

Improving Eye-gaze Mouse System Using Mouth Open Detection and Pop Up Menu (입 벌림 인식과 팝업 메뉴를 이용한 시선추적 마우스 시스템 성능 개선)

  • Byeon, Ju Yeong;Jung, Keechul
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.12
    • /
    • pp.1454-1463
    • /
    • 2020
  • An important factor in eye-tracking PC interface for general paralyzed patients is the implementation of the mouse interface, for manipulating the GUI. With a successfully implemented mouse interface, users can generate mouse events exactly at the point of their choosing. However, it is difficult to define this interaction in the eye-tracking interface. This problem has been defined as the Midas touch problem and has been a major focus of eye-tracking research. There have been many attempts to solve this problem using blink, voice input, etc. However, it was not suitable for general paralyzed patients because some of them cannot wink or speak. In this paper, we propose a mouth-pop-up, eye-tracking mouse interface that solves the Midas touch problem as well as becoming a suitable interface for general paralyzed patients using a common RGB camera. The interface presented in this paper implements a mouse interface that detects the opening and closing of the mouth to activate a pop-up menu that the user can select the mouse event. After implementation, a performance experiment was conducted. As a result, we found that the number of malfunctions and the time to perform tasks were reduced compared to the existing method.

Development of a Dynamic Motor on Smart Touch Control of one Point Linkage drag (1 포인트 드래그 연동 스마트 터치 제어용 다이나믹 모터 개발)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.327-332
    • /
    • 2015
  • Educational robot was introduced as an effective educational tool is to foster scientific creativity and learn the basic principles of science are applied to change the configuration of the educational after-school learning kits for science education. SMEs as a tool to foster scientific creativity center and a variety of educational robot technology and the wide range of games for students and robotic technology development, existing e-Learning by downloading mp3 music or learning content for the robot, such as the provision of specialized content Although the technology is still being developed to take advantage of the professional community formation is insufficient side. Currently, one-point linkage drag Smart Touch control dynamic motor development does not need this motor development is possible for users to easily.

A Study on Evaluation of an Automatic Tool Compensation System in CNC Machine Tool (CNC 공작기계에서의 자동공구 보정시스템의 평가에 관한 연구)

  • 정상화;신현성;김현욱
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.371-375
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. In this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF

Development of an Automatic Tool Compensation System for M/C (머시닝센터용 자동공구보정시스템의 개발)

  • 정상화;신현성;김현욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.48-54
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. in this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF

A Study on Measurement for Endmill Dia. using Electric Contact Method (공구마모보정을 위한 전기접점식 자동공구 보정시스템 개발)

  • 정상화;신형성;나윤철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.445-449
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. In this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF