• Title/Summary/Keyword: total water

Search Result 12,328, Processing Time 0.048 seconds

Occurrence Of Fecal Pollution Bacteria In The Water Of Lake Eui-Am (의암땜 하류수역의 분변성 오염세균류의 분포)

  • Choe, Sang;Kim, Geon Chee
    • 한국해양학회지
    • /
    • v.5 no.2
    • /
    • pp.59-64
    • /
    • 1970
  • The purpose of the study was to gather basic bacteriological data regarding the quality of Korean surface waters. Total coliforms, fecal coliforms and fecal Streptococci survey in the water of Lake Eui-Am were undertaken by the membrance filter technique. A total of 37 samples were collected in August 14, 1970. Total coliforms were detected in all samples, fecal coliforms and fecal Streptococci were detected in 68% and 82% of samples, respectively. Bacterial densities of the lake water were varied by station and depth. The numbers of bacteria per 100ml of the lake water were; 8-225(65.3 average) for the total coliforms, 0-112(26.2 average) for the fecal coliforms, 0-77(25.8 average) for the fecal Streptococci, and 8-302 (91.1 average) for the total number of total coliforms and fecal Streptococci. These results suggest that the Eui-Am lake water is only lightly polluted and indicate that the lake water, properly maintained, is a source of raw water of good bacteriological quality. Three forms of fecal pollution bacteria tend to increase with depth. This is believed that the suspended matter with conglomerated bacteria plays an important role in regulating of bacterial densities in summer season.

  • PDF

Study on Estimation and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model (유역모형을 이용한 유량조건별 배출계수 산정 및 활용방안 연구)

  • Hwang, Ha-Sun;Rhee, Han-Pil;Park, Jihyung;Kim, Yong-Seok;Lee, Sung-Jun;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.653-664
    • /
    • 2015
  • TPLMS (Total water pollutant load management system) that is the most powerful water-quality protection program have been implemented since 2004. In the implementation of TPLMS, target water-quality and permissible discharged load from each unit watershed can be decided by water-quality modeling. And NPS (Non-point sources) discharge coefficients associated with certain (standard) flow are used on estimation of input data for model. National Institute of Environmental Research (NIER) recommend NPS discharge coefficients as 0.15 (Q275) and 0.50 (Q185) in common for whole watershed in Korea. But, uniform coefficient is difficult to reflect various NPS characteristics of individual watershed. Monthly NPS discharge coefficients were predicted and estimated using surface flow and water-quality from HSPF watershed model in this study. Those coefficients were plotted in flow duration curve of study area (Palger stream and Geumho C watershed) with monthly average flow. Linear regression analysis was performed about NPS discharge coefficients of BOD, T-N and T-P associated with flow, and R2 of regression were distributed in 0.893~0.930 (Palger stream) and 0.939~0.959 (Geumho C). NPS Discharge coefficient through regression can be estimated flexibly according to flow, and be considered characteristics of watershed with watershed model.

Population Dynamics of Zacco platypus in Gap-Stream and Its Relation with Water Quality

  • Shin, Young-Eun; Choi, Ji-Woon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.422-431
    • /
    • 2009
  • This study was to provide basic data for aquatic ecosystem research using fishes. Field sampling was carried out at five selected sites of Gap Stream, and fish samples, especially for a selection of sentinel species were collected three times in June, September, and October 2007. We analyzed total length distribution of Zacco platypus in relation with the season and the sampling sites, and then compared with total body weight, condition factor (K), and age distribution of the fish. The fish population data were compared with physico-chemical water quality, obtained from the Ministry of Environment, Korea. Water quality analysis showed a significant nutrient enrichment, based on total nitrogen (TN) and total phosphorus (TP), and organic matter pollution, based on biological oxygen demand (BOD) and chemical oxygen demand (COD) in the Site 5, which is directly influenced by wastewater disposal plant (WDP). Population analysis of the sentinel species showed that the total number of individuals, age distribution, and the population size-structure were influenced by the effluents from the WDP, and that reproductive failure of young-age population were evident in Site 5. According to the relation analysis of total weight to K, the disturbed population was mainly attributed to combined effects of habitat modifications and chemical degradations. Regression analysis of K values against water quality parameters showed significant (p<0.05) positive relations with nutrient and organic matter contents. Our data suggest that the population structure using a sentinel fish species reflected the ambient water quality in the stream and that diagnosis of aquatic ecosystem health using Z. platypus population may be practical for water resource and ecosystem conservations.

Property of Filature Water against the Solubility of Cocoon Layer Sericin Seoul National Silk Conditioning House (제사용수의 수질이 견층 세리신(Sericin) 용해에 미치는 영향 (제2보))

  • 김병호;원성희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 1973
  • 1. The sericin solubility increased rapidly as the increase of water M-alkalinity. 2. The acidity of the treated water was nutralized at the over 25ppm of M-alkalinity. 3. The more M-alkalinity of the sample water is, the more M-alkalinity was found after cocoon treat. 4. The total hardness of sample water seemed to be droped as M-alkalinity increased. 5. The sericin solubility also seemed to be droped as the increase of water acidity. 6. In case of treat finish with cocoon, the acidity and total hardness seemed to increase as the acidity of the water increased, but M-alkalinity was nutralized at 20~40 ppm of water acidity or the M-alkalinity could not be found in case over 40ppm of acidity. 7. In case increase of iron component with sample water, sericin solubility seemed to drop down, and mangan component showed the same nature but dull drop. 8. After cocoon was treated with water, acidity, M-alkalinity and total hardness were increased by the extraction from cocoon shell because of pH and treating temperature but not because of iron componnent. Mangan component, however, affected as to increase of acidity and total hardness but to decrease for M-alkalinity. 9. In case change of M-alkalinity and total hardness, sericin solubility has increased also. 10. In case constant pH and total hardness, the more M-alkalinity is, the more sericin solubility was found. 11. In case constant pH, total hardness, and M-alkalinity, the more acidity is, the less sericin solubility was found. 12. In case constant pH(6.8) and M-alkalinity, the more total hardness is, the less sericin solubility was found. 13. Though the combination of water, high solubility water, medium solubility water and low solubility water were prepared. The high solubility water desolved sericin 2.2% more than low solubility water. And the medium solubility water desolved sericin as much as 2.4~2.9%. 14. It was found that the most important factors for filature water are pH, M-alkalinity, acidity and total hardness which may need more words for optimum filature water development. 15. In case of repeat use of water, the buffer action of water has increased so that the sericin solubility to be decreased.

  • PDF

Anhui Water Resource Situation and General Plan

  • Yiqun, Hou
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.67-73
    • /
    • 2007
  • Anhui Province, with a total north-south length of 570km and an east-west width of 450km and a total area of 139.6 thousand km2, accounts for 1.45% of China's total area. The landform and land feature of Anhui Province is diverse, and generally it can be divided into 5 natural regions: (1) Huaibei Plain; (2) Jianghuai Hillocks; (3) Dabie Mountains in the West of Anhui Province; (4) Yanjiang Plain, (5) Mountain Area of southern Anhui Province. Anhui Province is located in the transitional zone of warm and humid zone and subtropical zone, and its mean annual precipitation is 800-1800mm. The province, which has diverse climate, multiple land forms and many rivers and lakes, passes three basins (Huaihe River, Yangtze River and Xin'an River) and has large differences in the time distribution and regional distribution of water resource. Therefore, the development and usage conditions of the water resource in different regions are different.

  • PDF

Evaluation of Total, Water-soluble and Hexavalent Chromium Contents in Construction Materials(Concretes, Cements)

  • Choi, In-Ja;Yoon, Chung-Sik;Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.497-501
    • /
    • 2007
  • The objective of the study is to determine the contents of total chromium, water-soluble chromium and hexavalent chromium in cements and concretes specimens taken from manufacturing or construction sites. Chromate is an allergen that is widespread in the environment and is richly contained in cements. Metals were extracted with microwave oven and analyzed by atomic absorption spectrometer. Hexavalent chromium was analysed by ion chromatography. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in cements were $36.02{\sim}108.01,\;15.95{\sim}89.01\;and\;26.77{\sim}89.61\;mg/kg$, respectively. The concentrations of hexavalent chromium in cements were higher than 2 mg/kg, a maximum value recommended in Northern European Countries. The concentrations of total chromium, water-soluble chromium and hexavalent chromium in concretes were $17.44{\sim}76.25,\;0.98{\sim}17.71\;and\;ND{\sim}24.13\;mg/kg$, respectively. Especially Hexavalent chromium was detected only from concrete specimens from construction sites. It is oxidized or reduced status by environmental condition or surrounding materials.

Effects of TDS on formation of THMs in drinking water treatment (정수처리에서 TDS가 THMs 생성에 미치는 영향)

  • Lee, Seulki;Kwak, Yeonwoo;Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.225-234
    • /
    • 2019
  • This study is focused on effects of factors that affect the formation of THMs during chlorination in drinking water treatment. During the chlorination, chlorine consumption is increased by increasing the initial chlorine dose, the pH and the total dissolved solid (TDS) concentration. Also THMs formation is increased up to $58.82{\mu}g/L$ and $55.54{\mu}g/L$ by increasing initial chlorine concentration and increasing pH. However, concentration of chloroform is decreased by increasing TDS concentration. This is caused the cation($Na^+$) of the total dissolved solids preferentially reacts with the functional groups of the organic material which influence the trihalomethane formation. But total trihalomethane formation is increased up to $127.46{\mu}g/L$ by $Br^-$ contained in the total dissolved solids. DOC reduction was not influenced by any of the factors.

Real Time Water Quality Forecasting at Dalchun Using Nonlinear Stochastic Model (추계학적 비선형 모형을 이용한 달천의 실시간 수질예측)

  • Yeon, In-sung;Cho, Yong-jin;Kim, Geon-heung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.738-748
    • /
    • 2005
  • Considering pollution source is transferred by discharge, it is very important to analyze the correlation between discharge and water quality. And temperature also influent to the water quality. In this paper, it is used water quality data that was measured DO (Dissolved Oxygen), TOC (Total Organic Carbon), TN (Total Nitrogen), TP (Total Phosphorus) at Dalchun real time monitoring stations in Namhan river. These characteristics were analyzed with the water quality of rainy and nonrainy periods. Input data of the water quality forecasting models that they were constructed by neural network and neuro-fuzzy was chosen as the reasonable data, and water quality forecasting models were applied. LMNN (Levenberg-Marquardt Neural Network), MDNN (MoDular Neural Network), and ANFIS (Adaptive Neuro-Fuzzy Inference System) models have achieved the highest overall accuracy of TOC data. LMNN and MDNN model which are applied for DO, TN, TP forecasting shows better results than ANFIS. MDNN model shows the lowest estimation error when using daily time, which is qualitative data trained with quantitative data. If some data has periodical properties, it seems effective using qualitative data to forecast.

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

A study on the Character of Water Quality according to the Flux in Pal-Dang Reservoir (팔당호 유량변동에 따른 수질특성에 관한 연구)

  • 김종민
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.12-24
    • /
    • 1995
  • I tried to evaluate the reason of the monthly variation of water quality according to the hydrologic character of Pal- dang reservoir inflow variation. The result of this study is as below; 1 ) COD, BOD, Total- nitrogen and Total- phosphate concentration increase generally according to the flux and Total- phosphate concentration is the most affected item by flux. 2) COD, BOD, Total- nitrogen and Total- phosphate concentration increase according the flux, but they begin to decrease at the below point ; COD · 1,154 CMS, BOD : 1,007 (CMS cubicmeter per second ) and Inflow- Concentration interrelation formula is as below; table omitted.

  • PDF