• Title/Summary/Keyword: total system

Search Result 16,034, Processing Time 0.048 seconds

INCORPORATION OF TOTAL TIME MANAGEMENT INTO HIGHWAY PROJECT TIME MANAGEMENT SYSTEM

  • Yuan Jianbo;Liu Weijun;Zhang Jianren
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.796-801
    • /
    • 2005
  • Time management is one of the critical tasks in project management. Based on the theories of total quality management, this authors presented a project time management method, total time management (TTM), so as to facilitate highway project time management. This paper discussed the four fundamental characteristics of TTM: total factors management, staff management, project life cycle management, and Plan-Do-Check-Action (PDCA) cycle management. Now, most managers use computer software to manage the project. In order to make the theory of TTM more executable, the authors develop a project time management system suitable for TTM. This paper presents this time management system's analysis processes including system requirement, key functions etc..

  • PDF

An On-line Algorithm to Search Minimum Total Error for Imprecise Real-time Tasks with 0/1 Constraint

  • Song Gi-Hyeon
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.12
    • /
    • pp.1589-1596
    • /
    • 2005
  • The imprecise real-time system provides flexibility in scheduling time-critical tasks. Most scheduling problems of satisfying both 0/1 constraint and timing constraints, while the total error is minimized, are NP complete when the optional tasks have arbitrary processing times. Liu suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on uniprocessors for minimizing the total error. Song et al suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on multiprocessors for minimizing the total error. But, these algorithms are all off-line algorithms. On the other hand, in the case of on line scheduling, Shih and Liu proposed the NORA algorithm which can find a schedule with the minimum total error for a task system consisting solely of on-line tasks that are ready upon arrival. But, for the task system with 0/1 constraint, it has not been known whether the NORA algorithm can be optimal or not in the sense that it guarantees all mandatory tasks are completed by their deadlines and the total error is minimized. So, this paper suggests an optimal algorithm to search minimum total error for the imprecise on-line real-time task system with 0/1 constraint. Furthermore, the proposed algorithm has the same complexity, O(N log N), as the NORA algorithm, where N is the number of tasks.

  • PDF

Development of Plant Safety Information Management System for Preventive Maintenance (사전예방을 위한 설비안전정보시스템 개발)

  • Kim Tae Hwan;Yang Kwang Mo;Choi Seung Hee;Kang Kyung Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.7 no.2
    • /
    • pp.1-12
    • /
    • 2005
  • TPM(Total Productive Management) that is enforcing introducing more than $80\%$ in domestic manufacturing industry is using total plant efficiency by the evaluation index, and as a result, can see a lot of examples that plant productivity is increased. This study's purpose centers total productive management activities that is management system for total plant efficiency's maximization, plant information system that total productive management activities factor that is enforcing in manufacturing industry can develop evaluation model that can evaluate qualitative activities by quantitative activities in process that maximize total plant efficiency wishes to do design.

Experimental of the Rotaing Cryogenic System (회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구)

  • 이창규;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

Automated On-Line Digestion System for the Determination of Total Phosphorus (총 인 분석을 위한 자동 전처리 시스템)

  • 정형근;조영일;김범식;박주형
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • An on-line digestion system based on the flow injection analysis technique was presented for the determination of total phosphorus. The system converts condensed and organic phosphoruses into orthophosphate that can be analyzed spectrophotometically. The reaction between orthophosphate and ammonium molybdate in a strong acid medium forms the yellow complex of phosphomolybdate which is next reduced to a molybdic blue complex by stannous chloride. The quantitation of orthophosphate is based on the absorbance of the molybdic blue. To determine total phosphorus, the digestion system was installed between the sample injector and the reaction coil with the added lines of digestion solution(potassium persulfate+sulfuric acid) and the $H_2O$ carrier. The system has shown that the digestion efficiencies were greater than 95% for the typical condensed and organic phosphoruses. When tripolyphosphate standards were used, the calibration data showed that the linear dynamic range extended to a concentration of 1.5ppm with the detection limit of 25ppb total phosphorus. The typical relative standard deviation was less than 2%. The proposed system was successfully applied to lake water, wastewater, and streamwater. The analytical variables such as digestion efficiency, analysis time, and reproducibility were evaluated and compared with the manual digestion method.

  • PDF

A Novel Grid-Connected PV PCS with New High Efficiency Converter

  • Min, Byung-Duk;Lee, Jong-Pil;Kim, Jong-Hyun;Kim, Tae-Jin;Yoo, Dong-Wook;Ryu, Kang-Ryoul;Kim, Jeong-Joong;Song, Eui-Ho
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.309-316
    • /
    • 2008
  • In this paper, new topology is proposed that can dramatically reduce the converter power rating and increase the efficiency of total PV system. Since the output voltage of PV module has very wide voltage range, in general, the DC/DC converter is used to get constant high DC voltage. According to analysis of PV characteristics, in proposed topology, only 20% power of total PV system power is needed for DC/DC converter. DC/DC converter used in proposed topology has flat efficiency curve at all load range and very high efficiency characteristics. The total system efficiency is the product of that of converter and that of inverter. In proposed topology, because the converter efficiency curve is flat all load range, the total system efficiency at the low power range is dramatically improved. The proposed topology is implemented for 200kW PCS system. This system has only three DC/DC converters with 20kW power rating each other. It is only one-third of total system power. The experiment results show that the proposed topology has good performance.

Effective Compensation of the Distorted 1.12 Tbps WDM Signals Using Optimization of Total Dispersion

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.377-381
    • /
    • 2007
  • Nonlinear effects and chromatic dispersion are the main causes of pulse degradation in high bit-rate WDM transmission systems and several architectures have been proposed to compensate them by means of optical phase conjugation. In this paper, a new method to exploit an optical phase conjugator (OPC) for nonlinearity and dispersion cancellation is disclosed. The proposed method is using optimal total dispersion of each fiber sections and it is simpler than those previously described in literature. Power penalty between WDM channels and the maximum launch power in $28{\times}40$ Gbps WDM transmission system designed by optimal total dispersion are more decreased and more increased than those in the conventional WDM transmission system with OPC, respectively. Furthermore, optimal total dispersion proposed in this research should provide the flexible design of WDM system, which less depends on OPC position.

A Study on the Identification and Improvement of Dynamic Characteristics of Large Structure by Component Mode Synthesis Method (부분 구조합성법을 이용한 대형구조물의 동특성 규명 및 개선에 관한 연구)

  • 오재응;이정환;임동규
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.327-335
    • /
    • 1994
  • In this paper, to identify the dynamic characteristics of antenna system, the antenna is divided into 4 components and those were analyzed with a conventional FEM package MSC/NASTRAN. Using a Component Mode Synthesis Method, dynamic characteristics of total system is also identified. The Coherence of each component to total system is evaluated by using strain and kinetic component to total system is evaluated by using strain and kinetic energy. The improving strategy of dynamic characteristics is suggested by changing mass and stiffness of large coherence components.

  • PDF

The Attitude on Introduction for Total Amount in Terrestrial Broadcasting Television: Comparison of Public and Professional Awareness (지상파 TV에 광고총량제 도입에 대한 태도: 일반인과 전문가 인식비교)

  • Jung, Jin-Tack
    • Journal of Digital Convergence
    • /
    • v.13 no.1
    • /
    • pp.205-213
    • /
    • 2015
  • Era of multi-channel digital multimedia on the Internet, cable, satellite and IPTV and the growth of new media such as terrestrial broadcast advertising with the poor rating has also dropped sharply. In this situation, terrestrial TV suggesting the introduction for total amount system appearing comments. In this study, the introduction of these intermediate advertising the public and professional awareness about the issue by comparing the introduction for total amount advertising feasibility was done in the purpose. The results were as follows. First, Studies on terrestrial TV suggesting the introduction of total amount system and public opinion about the differences in perception between experts is high. Second, Both the public and professionals about the total amount system preferred application stage were in favor of gradual for/limited permit cross-media. Third, the general population was higher than the positive response from experts about the benefits of the total amount system. Finally, the general public about the disadvantages of the total amount system they were more positive response than the experts. The introduction for total amount system validity of these data for future total amouny system to provide a basis for enforcement is expected to give.

The status nursing care delivery system and the influencing factors on quality of nursing care (간호전달체계 현황 및 간호서비스의 질에 영향을 미치는 요인)

  • Kim, Ji-Yeun;Park, Bo-Hyun;Ko, Yu-Kyung
    • Korea Journal of Hospital Management
    • /
    • v.21 no.2
    • /
    • pp.24-36
    • /
    • 2016
  • The aims of this study is to investigate the status of nursing care delivery systems and nurse staffing levels and to analyze differences in the quality of nursing care by the type of nursing care delivery system. This research was based on data from 723 nurses working in 55 medical and surgical units in 26 general hospitals. Descriptive statistics on nurse staffing levels and the nursing care delivery system, and multi-level logistic regression were used to estimate the determinants of quality of nursing care. The number of patients per nurse is 17.74 patients in functional nursing care and 15.56 patients in total nursing care. In comparison to hospitals adopting total nursing care, hospitals with functional nursing care had greater patients. The nurses rated units using total nursing care as significantly better quality of nursing care than the units with functional nursing care. Total nursing care or modified total nursing care, rather than functional nursing care, could lead to improvement in the quality of care(total nursing care OR=3.895, modified total nursing care OR=2.475). Patient-centered approaches under proper circumstances can be successfully implemented and the positive effects demonstrated.