• Title/Summary/Keyword: total suspended particulate

Search Result 149, Processing Time 0.027 seconds

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation (대기경계층과 연안순환에 의한 부유입자의 재순환)

  • Choe, Hyo
    • Journal of Environmental Science International
    • /
    • v.13 no.8
    • /
    • pp.721-731
    • /
    • 2004
  • The dispersion of suspended particulates in the coastal complex terrain of mountain-inland basin (city)-sea, considering their recycling was investigated using three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). Convective boundary layer under synoptic scale westerly wind is developed with a thickness of about I km over the ground in the west of the mountain, while a thickness of thermal internal boundary layer (TIBL) is only confined to less than 200m along the eastern slope of the mountain, below an easterly sea breeze circulation. At the mid of the eastern slop of the mountain, westerly wind confronts easterly sea breeze, which goes to the height of 1700 m above sea level and is finally eastward return flow toward the sea. At this time, particulates floated from the ground surface of the city to the top of TIBL go along the eastern slope of the mountain in the passage of sea breeze, being away the TIBL and reach near the top of the mountain. Then those particulates disperse eastward below the height of sea-breeze circulation and widely spread out over the coastal sea. Total suspended particulate concentration near the ground surface of the city is very low. On the other hand, nighttime radiative cooling produces a shallow nocturnal surface inversion layer (NSIL) of 200 m thickness over the inland surface, but relatively thin thickness less than 100m is found near the mountain surface. As synoptic scale westerly wind should be intensified under the association of mountain wind along the eastern slope of mountain to inland plain and further combine with land-breeze from inland plain toward sea, resulting in strong wind as internal gravity waves with a hydraulic jump motion bounding up to about 1km upper level in the atmosphere in the west of the city and becoming a eastward return flow. Simultaneously, wind near the eastern coastal side of the city was moderate. Since the downward strong wind penetrated into the city, the particulate matters floated near the top of the mountain in the day also moved down along the eastern slope of the mountain, reaching the. downtown and merging in the ground surface inside the NSIL with a maximum ground level concentration of total suspended particulates (TSP) at 0300 LST. Some of them were bounded up from the ground surface to the 1km upper level and the others were forward to the coastal sea surface, showing their dispersions from the coastal NSIL toward the propagation area of internal gravity waves. On the next day at 0600 LST and 0900 LST, the dispersed particulates into the coastal sea could return to the coastal inland area under the influence of sea breeze and the recycled particulates combine with emitted ones from the ground surface, resulting in relatively high TSP concentration. Later, they float again up to the thermal internal boundary layer, following sea breeze circulation.

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation

  • Choi, Hyo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.19-26
    • /
    • 2003
  • The dispersion of recycled particulates in the complex coastal terrain containing Kangnung city, Korea was investigated using a three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). The results show that particulates at the surface of the city that float to the top of thermal internal boundary layer (TIBL) are then transported along the eastern slope of the mountains with the passage of sea breeze and nearly reach the top of the mountains. Those particulates then disperse eastward at this upper level over the coastal sea and finally spread out over the open sea. Total suspended particulate (TSP) concentration near the surface of Kangnung city is very low. At night, synoptic scale westerly winds intensify due to the combined effect of the synoptic scale wind and land breeze descending the eastern slope of the mountains toward the coast and further seaward. This increase in speed causes development of internal gravity waves and a hydraulic jump up to a height of about 1km above the surface over the city. Particulate matter near the top of the mountains also descends the eastern slope of the mountains during the day, reaching the central city area and merges near the surface inside the nocturnal surface inversion layer (NSIL) with a maximum ground level concentration of TSP occurring at 0300 LST. Some particulates were dispersed following the propagation area of internal gravity waves and others in the NSIL are transported eastward to the coastal sea surface, aided by the land breeze. The following morning, particulates dispersed over the coastal sea from the previous night, tend to return to the coastal city of Kangnung with the sea breeze, developing a recycling process and combine with emitted surface particulates during the morning. These processes result in much higher TSP concentration. In the late morning, those particulates float to the top of the TIBL by the intrusion of the sea breeze and the ground level TSP concentration in the city subsequently decreases.

  • PDF

A Study on the Size Distribution of Suspended Particulate in Broiler Houses (육용계사내 부유먼지의 입도 분포에 관한 연구)

  • 김종오;용준환
    • Korean Journal of Poultry Science
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 1993
  • Environmental measurements were made in 10 broiler confinement houses in order to characterize dust contaminants. Particles were collected by filters on nine stages Anderson Air Sampler, The obtained results were summarized as follows ; 1. The concentrations of the total suspended particles(TSP) were 7.584 mg/$m_3$~11.589mg/$m_3$ in 10 day old broiler houses and 15.836 mg/$m_3$~22.471 mg/$m_3$ in 30 day old broiler houses. 2. The concentrations of the coarse particles were 4.974 mg/$m_3$~18.981 mg/$m_3$ in 10 broiler confinement houses. Therefore, it was found that the coarse particles contributed to TSP between 65.6% and 85.0%. 3. The dust levels were higher in 30 day old broiler houses with TSP averaging about 19.341 mg/$m_3$ than 9.491 mg/$m_3$ in 10 day old broiler houses. In view of the above results , It was concluded that domestic broiler houses need artificial ventilation system.

  • PDF

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.

밀폐된 공간에서 환기에 의한 ETS 성분 제거

  • 황건중;이문수;나도영
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.1
    • /
    • pp.102-108
    • /
    • 1999
  • This study was conducted to evaluate the ventilation to remove gases, vapor and particles of environmental tobacco smoke(ETS) in a closed room. The ventilation rate choosed were 0.445 ㎥/min, 0.528 ㎥/min, and 0.625 ㎥/min. ETS components measured were total suspended particle(TSP), ultraviolet particulate matter(UVPM), fluorescent particulate matter(FPM), solanesol, carbon dioxide($CO_2$), carbon monoxide(CO), nicotine, and 3-ethenylpyri-dine(3-EP). The concentration of ETS components measured rapidly decreased as increasing ventilation rate, but the removal efficiency by ventilation was different from each ETS compounds. The $CO_2$, and CO, gaseous components of ETS, were dominant components to be removed from the room by ventilation. The ventilation with 0.528 ㎥/min for 1 hr was enough to remove over 99% of those gaseous components. Nicotine and 3-EP needed the ventilation for 2 hrs to reduce over 95 % of those components. As the same ventilation rate, 99 % of TSP and solanesol concentration were removed from the room within 2 hrs, UVPM and FPM concentration decreased 90 %.

  • PDF

A Study on Thermal Characteristic Carbon and other Elements in Suspended Particulates (대기 입자상물질중 탄소(C)등의 열적특성에 관한 조사연구)

  • 황경철
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.31-39
    • /
    • 1990
  • An analytical method for particulate carbon and other elements by using elemental analyzer was investigated. Carbon, hydrogen, and nitrogen was determined as CO$_{2}$, H$_{2}$, and N$_{2}$, respectively. Organic was determined after scparation from elemental carbon(Cae) by volatilization and thermal decomposition in a heated helium flow. With organic materials examined in this reprot, more than 90% of carbon was detected as above 600$^{\circ}$C. But it is considered that a few percents of some compounds were charred above 550$^{\circ}$C. A small amount of Cae was oxidized in the inert atmosphere above 850$^{\circ}$C, but the reason was not explained clearly. Based on the thermal chracteristics of Cao it was found that the optimum temperature of heating in the helium flow of an elemental analyzer for Cao analysis is 630$^{\circ}$C. Carbon in a sample after removing Cao was assumed as Cae and the gramatom ratio of hydrogen to carbon in the sample was 0.4 and less. Rescovery of nitrogen derived from some ammonium salts and nitrates was 100% by two-step measurement with elemental analyzer. By the analytical method investigated in this report, carbon and other elements in suspended particulates(S.P) collected at an urban area in Seoul were measured. There was a good correlation between total nitrogen in SP measured by elemental analyzer and nitrogen estimated form ammonium ions and nitrate ions in SP. The nitrogen from these ions accounts for 80% of the total nitrogen. It is further suggested that the residue(20%) of the total nitrogen is attributed to the other nitrogeneous compounds.

  • PDF

Organic Matter in the Sediments of Youngsan River Estuary : Distribution and Sources (영산강 하구역 퇴적물의 유기물 분포와 기원)

  • Woo, Jun-Sik;Choi, Heeseon;Lee, Hyo-Jin;Kim, Tae-Ha
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1375-1383
    • /
    • 2014
  • Total organic carbon(TOC), Total nitrogen(TN), and carbon and nitrogen stable isotopes were measured in the sediment and suspended parties in fresh lake water and saline estuarine water to determine the sources of Particulate organic matter(POM) in the sediments of the Youngsan river estuary. POM in the freshwater discharge water was mostly phytoplankton origin with little trace of terrestrial plants. POM from phytoplankton blooms formed in estuarine water in response to the nutrient enriched freshwater discharges was the most important sources of POM in the sediment near the dike, comprising more than 40% of the total organic matter. POM from freshwater phytoplankton and oceanic phytoplankton were also important sources of the sediment POM, and their contributions varied with the distances from the dike. Contribution of freshwater phytoplankton to sediment POM decreased from the dike to the outside of the estuary.

Long-term Variation of Ionic Constituent Concentrations in TSP at Jeju Island (제주지역 TSP 이온성분 농도의 장기 변화)

  • Ko, Hee-Jung;Kang, Chang-Hee;Kim, Won-Hyung;Lee, Soon-Bong;Kang, Hwa-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.420-431
    • /
    • 2010
  • The water-soluble components have been analyzed from the total suspended particulate (TSP) collected at Gosan site of Jeju Island for ten years (1997~2006), and the long-term variations of ionic constituent concentrations have been investigated in order to understand the pollution characteristics of atmospheric aerosols. Their mean concentrations were in the order of nss-${SO_4}^{2-}$ > $Na^+$ > ${NO_3}^-$ > $Cl^$ > ${NH_4}^+$ > nss-$Ca^{2+}$ > $K^+$ > $Mg^{2+}$. The ${NO_3}^-$ concentrations had increased somewhat smoothly compared to those of ${SO_4}^{2-}$ for the past 10 years, possibly indicating the recent energy consumption pattern changes in China. The concentrations of ionic aerosol components showed mostly higher values during the Asian Dust storm periods, and the concentration ratios of nss-$Ca^{2+}$, ${NO_3}^-$, and nss-${SO_4}^{2-}$ between the Asian Dust and Non-Asian Dust periods were 6.9, 2.4, and 1.3, respectively. The anthropogenic nss-${SO_4}^{2-}$, ${NO_3}^-$, ${NH_4}^+$ and the soil originated nss-$Ca^{2+}$ components showed high concentrations as the air parcels were moved from the Asia continent, on the other hand, their concentrations were relatively low as moving from the Northern Pacific into the Gosan area.

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.233-239
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water. The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg O$_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg O$_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

  • PDF

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • Journal of Navigation and Port Research
    • /
    • v.28 no.2
    • /
    • pp.155-159
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water, The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg$O_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg $O_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.