• Title/Summary/Keyword: total pressure drop

Search Result 155, Processing Time 0.032 seconds

A Feasibility Study of Simultaneous Measurement of Gas-Liquid Two-Phase Flowrate and Quality with a Sharp-Edged Orifice (차압유량계를 이용한 기액 2상유량 및 건도의 동시측정 가능성에 관한 연구)

  • 이상천;오홍의;김중엽
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.335-342
    • /
    • 1986
  • The feasibility of simultaneous measurement of gas-liquid tow-phase flowrate and quality with a sharp-edged orifice has been investigated. Instantaneous pressure drop curves were monitored for various combinations of gas and liquid flowrates in the bubbly flow regime and some statistical properties of the curves were calculated. The time-averaged value of pressure drop increases with increasing gas and liquid flowrate, whereas the mean amplitude and the intensity of fluctuation monotonically increase as void fraction becomes larger in the flow regime. The statistical furctions for the instantaneous curves indicate a consistent pattern throughout the flow regime and the probability density function, which as a single-peaked and symmetrical distribution, is well predicted by the Gaussian distribution function. The results indicate that simultaneous determination of two-phase flowrate and quality may be possible based upon the statistical analysis of instaneous pressure drop curves measured in a sharp-edged orifice.

The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger (직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성)

  • 임동렬;박상일;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

Optimization of a radiator for a MPFL system in a GEO satellite

  • Afshari, Behzad Mohasel;Abedi, Mohsen;Shahryari, Mehran
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.6
    • /
    • pp.701-709
    • /
    • 2017
  • One of the components that used in the satellite thermal control subsystem is the Mechanically Pumped Fluid Loop (MPFL) system; this system mostly used in geosynchronous orbit (GEO) satellites, and can transfer heat from a hot point to a cold point using the fluid which circulated in a closed loop. Heat radiates to the deep space at the cold plate to cool down the fluid temperature. In this research, the radiative heatexchanger (RHX) for a MPFL system is optimized. The genetic algorithm has been used for minimizing the total mass and pressure drop by considering a constant transferred heat rate at the heat exchanger. The optimization has been done in two cases. In case I, two parameters are considered as a goal function, so optimization is performed using NSGA-II method. Results of optimization are shown in the pareto diagram. In case II, the diameter of pipe is considered constant, so the optimized value for distances of the parallel pipes is obtained by using the genetic algorithm, in which the system has the least total mass. Results show that in the RHX, by increasing the pipe diameter, pressure drop decreases and total mass increases. Also by considering a constant value for pipe diameter, an optimum distance between pipes and pipe length are obtained in which the system has a minimum mass.

An Experimental Investigation of the Effect of the Entrance Shape of Sudden Contraction on Single and Two-Phase Pressure Drop in Horizontal Air-Water Flow (공기와 물의 수평유동에 있어 관의 급격한 입구축소 모양이 단상 및 이상유 압력강하에 미치는 영향에 관한 실험적 연구)

  • Chun, Moon-Hyun;Baek, Joo-Seok;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.123-133
    • /
    • 1989
  • The pressure drops through contractions in horizontal single and two-phase flow were investigated. A total of 167 measurements were made for four different entrance shapes to study the effects of the entrance shape on the pressure drop through a contraction in horizontal single and two-phase flow. From this data, pressure drops were calculated and compared with the pressure drops predicted by analytical models for single and two-phase flow. For single phase How the agreement between the data and predictions is within $\pm$25%, whereas for two-phase flow Hoopes model, which gives a better agreement than the homogeneous model, underpredicts the data as much as 45% In addition, the effects of void fraction and liquid phase mass velocity on the pressure drop through the sudden How channel contraction were investigated for two-phase flow.

  • PDF

A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump (보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구)

  • Lee, Kwon-Il;Jang, Hoon;Lee, Chi-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.541-547
    • /
    • 2022
  • Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

Effects of changes in blood pressure during brain vascular surgery on intraoperative neuromonitoring

  • Lee, Kyuhyun;Kim, Jaekyung
    • International journal of advanced smart convergence
    • /
    • v.9 no.3
    • /
    • pp.71-77
    • /
    • 2020
  • This study was conducted in order to determine how reductions in blood pressure during surgery affect intraoperative neuromonitoring. This retrospective study considered a total of 339 patients: 194 patients with normal neuromonitoring findings (57%), 145 (42%) with abnormal neuromonitoring findings, and 34 (10%) with postoperative neurological deficits. Comparisons between the three groups revealed that overall blood pressure during surgery, postoperative blood pressure, and the difference between the maximum and minimum blood pressure could affect the intraoperative neuromonitoring findings. While we indicate that a drop in blood pressure to below 70 mmHg could affect neuromonitoring results, differences in the dosage of anesthetic agents did not significantly affect reductions in blood pressure or neuromonitoring findings. The association of monitoring with blood pressure found in this study is expected to help future examiners. However, this study did not clarify the relationship between anesthesia and blood pressure and how it could affect intraoperative neuromonitoring. Therefore, further research on this part is thought to be necessary.

An Experimental Study on Heat Transfer Characteristics and Pressure Drop in Micro Plated Heat Exchangers with S-shape of Microchannel (S 형상의 마이크로 채널을 가진 마이크로 판형 열교환기의 열전달 특성 및 압력강하에 관한 실험적 연구)

  • Seo, Jang-Won;Kim, Yoon-Ho;Moon, Chung-Eun;Lee, Kyu-Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1876-1881
    • /
    • 2007
  • The micro plated heat exchangers were designed to transfer more heat/volume or mass than previous heat exchangers within the context of the design constraints specified. The increase of the surface-to-volume ratio results in an increase of the interfacial area. This enhances considerably the performance of a heat exchanger. This can be an important component in a wide range of applications fuel cell, aerospace, automotive, electronic system and home heating, etc). In this study, the performance evaluation of micro plated heat exchangers under the counter flows with straight and S-shaped channel are carried out. The pressure drop as well as inlet and outlet fluid temperature were measured at steady state under various operating conditions and the total heat transfer rate were also calculated.

  • PDF

Performance Evaluation of Double-Tube Condenser using Smooth and Micro-Fin Tubes for Natural Mixture Refrigerant (Propane/Butane)

  • Lee, Sang-Mu;Lee, Joo-Dong;Koyama, Shigeru;Park, Byung-Duck
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2007
  • The investigation has been made into the prediction of heat exchange performance of a counter flow type double-tube condenser for natural refrigerant mixtures composed of Propane/n-Butane or Propane/i-Butane in a smooth tube and micro-fin tube. Under various heat transfer conditions, mass flux, pressure drop and heat transfer coefficient of the mixed refrigerants were calculated using a prediction method, when the length of condensing tube, total heat transfer rate, mass flux and outlet temperature of coolant were maintained constant. Also, the predicted results were compared with those of HCFC22. The results showed that the mixed refrigerants of Propane/n-Butane or Propane/i-Butane could be substituted for HCFC22, while the pressure drop and overall heat transfer coefficient of the refrigerants were evaluated together.

의공산업의 현황과 전망

  • 고영환
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.91-93
    • /
    • 1989
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF

Hemodynamic Evaluation of Monoleaflet Polymer Valve (단엽식 고분자판막의 혈역학적 성능평가)

  • 김상현;장병철
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 1995
  • We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane. To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medicals prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volllme and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate.

  • PDF