• Title/Summary/Keyword: total load management

Search Result 415, Processing Time 0.026 seconds

Nutrient production from Korean poultry and loading estimations for cropland

  • Won, Seunggun;Ahmed, Naveed;You, Byung-Gu;Shim, Soomin;Kim, Seung-Su;Ra, Changsix
    • Journal of Animal Science and Technology
    • /
    • v.60 no.2
    • /
    • pp.3.1-3.9
    • /
    • 2018
  • Background: Poultry breeding has increased by 306% in Korea, inevitably increasing the production of manure which may contribute to environmental pollution. The nutrients (NP) in the manure are essential for crop cultivation and soil fertility when applied as compost. Excess nutrients from manure can be accumulated on the land and can lead to eutrophication. Therefore, a nutrient load on the finite land should be calculated. Methods: This study calculates the nutrient production from Korean poultry by investigating 11 broiler and 16 laying hen farms. The broiler manure was composted using deep litter composting while for layer deep litter composting, drying, and simple static pile were in practice. The effect of weight reduction and storing period during composting was checked. Three weight reduction cases of compost were constructed to calculate nutrient loading coefficients (NLCs) using data from; i) farm investigation, ii) theoretical P changes (${\Delta}P=0$), and iii) dry basis. Results: During farm investigation of broiler and layer with deep litter composting, there was a 68 and 21% N loss whereas 77 and 33% P loss was found, respectively. In case of layer composting, a loss of 10-56% N and a 52% P loss was observed. Drying manure increased the P concentrations therefore NLCs calculated using dry basis that showed quite higher reductions (67% N; 53% P). Nutrient loss from farm investigation was much higher than reported by Korean Ministry of Environment (ME). Conclusions: Nutrients in manure are decreased when undergo storing or composting process due to microbial action, drying, and leaching. The nutrient load applied to soil is less than the fresh manure, hence the livestock manure management and conservation of environment would be facilitated.

Performance Appraisal of Total Maximum Daily Loads: Performance on Development/Reduction Plan and Water Quality Status of Unit Watershed (수질오염총량관리제의 성과평가: 개발/삭감계획의 이행실적 및 단위유역의 수질 현황)

  • Park, Jae Hong;Park, Jun Dae;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.481-493
    • /
    • 2009
  • This study was conducted to performance appraisal of Total Maximum Daily Loads (TMDLs), especially in terms of performance on development & reduction plan and water quality status of unit watershed. Because load allocations for pollution sources were predicted redundantly by uncertainty of prediction, TMDLs master plan has been frequently changed to acquire load allocation for local development. Therefore, It need to be developed more resonable prediction techniques of water pollution sources to preventing the frequent change. It is suggested that the reduction amount have to be distributed properly during the planning period. In other words, it has not to be concentrated on the specific year (especially final year of the planning period). The reason why, if the reduction amount concentrate on the final year of the planning period, allotment loading amount could not be achieved in some cases (e.g., insufficiency of budget, extension of construction duration). If the development plan was developed including uncertain developments, it is necessary to be developed reduction plan considered with them. However, some of the plans in the reduction plan could not be accomplished in some case. Because, it is not considered financial abilities of local governments. Consequently, development plan must be accomplished to avoid uncertain developments, and to consider financial assistance to support the implementation of effective plan. Water quality has been improved in many unit watersheds due to the TMDLs, especially in geum river and yeongsang/seomjin river.

Determination of Pollutant Unit Loads from Various Transportation Landuses (교통관련 포장지역 비점오염원에서의 오염물질 유출원단위 산정)

  • Lee, So-Young;Lee, Eunju;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.543-549
    • /
    • 2008
  • Human activities and land-use practices are intensely widening the urban areas. High impervious surface areas cover much of urban landscapes and are the primary pollutant sources which can lead to water quality and habitat degradation in its watershed. As the urban areas expand, transportation land-use such as parking lots, roads, service areas, toll-gates in highways and bridges also increase. These land-uses are significant in urban pollution due to high imperviousness rate and vehicular activities. To regulate the environmental impacts and to improve the water quality of rivers and lakes, the Ministry of Environment (MOE) in Korea developed the Total Pollution Load Management System (TPLMS) program. The main objective is to lead the watershed for a low impact development. On a local scale, some urban land surfaces can be emitting more pollution than others. Consequently, in urban areas, the unit loads are commonly employed to estimate total pollutant loadings emitted from various land-uses including residential, commercial, industrial, transportation, open lands such as parks and golf courses, and other developed land like parking areas as a result of development. In this research, unit pollutant loads derived specifically from transportation land-uses (i.e. branched out from urban areas) will be provided. Monitoring was conducted over 56 storm events at nine monitoring locations during three years. Results for the unit pollutant loads of transportation land-use are determined to be $399.5kg/km^2-day$ for TSS, $12.3kg/km^2-day$ for TN and $2.46kg/km^2-day$ for TP. The values are higher than those of urban areas in Korean MOE and US highways. These results can be used by MOE to separate the pollutant unit load of transportation landuses from urban areas.

Above-ground Biomass and Crown Fuel Characteristics of Pinus densiflora in Yangyang, Gangwon Province (강원도 양양지역 소나무림의 지상부 바이오매스와 수관층 연료특성에 관한 연구)

  • Kim, Sungyong;Lee, Youngjin;Jang, Mina;Seo, Yeonok;Koo, Kyosang;Jung, Sungcheol;Kim, Kyungha
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.244-250
    • /
    • 2012
  • The objective of this study was to analyze the above-ground biomass and crown fuel characteristics of Pinus densiflora stands in Yangyang, Gangwon province. A total of thirteen representative trees were destructively sampled in Yangyang region. The results showed that the stem density ($g{\cdot}cm^{-3}$) was 0.347~0.409, whereas the above-ground biomass expansion factors ranged from 1.251~1.419. In terms of crown fuel biomass, the above-ground biomass was $161.6Mg{\cdot}ha^{-1}$ while the stem biomass, branch biomass and needle biomass were $126.4Mg{\cdot}ha^{-1}$, $29.3Mg{\cdot}ha^{-1}$ and $5.9Mg{\cdot}ha^{-1}$, respectively. Needles and twigs with less than 1 cm diameter accounted 45.2% of the total crown fuel load. The available crown bulk density, which was calculated by dividing the crown fuel load to the crown volume, was $0.178kg{\cdot}m^{-3}$. The results of this study on the biomass and carbon stocks estimation of the Pinus densiflora together with the crown fire hazard assessment based on crown fuel loads are very significant information for the forest managers.

A Study to Evaluate Impervious Area Ratio by Geographic Information Data (지리정보자료에 따른 불투수면적률 산정 결과에 대한 연구)

  • Min Suh Chae;Kyoung Jae Lim;Joong-Hyuk Min;Minji Park;Jichul Ryu;Mijin Lee;Sohyeon Park;Youn Shik Park
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.2
    • /
    • pp.142-152
    • /
    • 2023
  • Infiltration is a process by which precipitation infuses into subsurface soils. The process determines the surface flow and baseflow volume, and it is one of most important hydrological processes regarding nonpoint source pollution management. Therefore, the Ministry of Environment has developed a guideline to determine the impervious area ratio to understand the hydrological process in administrative districts and watersheds. The impervious area ratio can be determined using land use or land cover maps. Three approaches were explored to determine the impervious area ratio in 25 districts in Seoul. The impervious area ratio was determined by employing the Land registration map and Land property data in the first approach, Land property map in the second approach, and Land cover map in the third approach. The ratio ranged from 38.96% to 83.01% in the first approach, 38.98% to 83.02% in the second approach, and 37.62% to 76.63% in the third approach. Although the ranges did not provide any significant differences in the approaches, some districts displayed differences up to 9.48% by the approach. These differences resulted from the fact that the data were land use or land cover, especially in the area of airport, residential complex area, and school sites. In other words, division of the pervious and impervious areas in an individual plot was not allowed in the Land registration map, while it was allowed in the Land cover map. Therefore, it was concluded that there is a need to revise the guideline so that a reasonable impervious area ratio can be determined in the districts.

Characteristics of Non-point Pollutant from Highway Toll Gate Landuse (고속도로 영업소지역에서의 비점오염물질 유출특성)

  • Lee, Eun-Ju;Son, Hyun-Geun;Kang, Hee-Man;Kim, Lee-Hyung
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.185-192
    • /
    • 2007
  • Newly constructed road is a requisite to be able to carry out BMPs (Best Management Practices) under TMDL(Total Maximum Daily Load) program of the Ministry of Environment. BMPs require pollutant source control during road construction and wash off reduction plan as well as maintenance practices subsequent to construction on the purpose of discharging the minimum wash off non-point source pollutants. The objective of this study is to provide supportive discharged data in evaluating the discharged non-point pollutant load from a highway toll gate area. It can be applied to manage non-point source pollutants on roads. The results validate the first flush phenomenon that it is known to be one of the wash off characteristics in paved area. In addition, the load per unit area and load per unit rainfall duration applying EMC are calculated. The mean load per unit rainfall duration is assessed to be $533.7mg/m^2-hr$ for TSS, $396.2mg/m^2-hr$ for COD, $17.0mg/m^2-hr$ for TN, and $4.8mg/m^2-hr$ for TP. These results show the unitload taken from monitoring are higher than the unit load suggested in the TMDL. It is important to adopt real pollutant unit for road to be able to perform BMP successfully.

  • PDF

Watershed Management Plan through Water Quality Monitoring for Main Branches of 4 Water Systems in Chungcheongnamdo (충청남도 4대수계 주요 지류하천 수질 모니터링을 통한 유역 관리 방안)

  • Park, Sanghyun;Kim, Hongsu;Cho, Byunguk;Moon, Eunho;Choi, Jinha
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.163-172
    • /
    • 2016
  • This study aimed to develop a plan for effective performance of a watershed through correct identification of a river watershed by using the flowrate of the river and water quality data, which is the basis for the establishment of the water environment policy. The target river for water quality improvement was selected based on the monitoring result for 4 water systems in Chungcheongnamdo province in the recent 3 years. The result of analysis for the distribution of discharge capacity by a pollution source group for the water quality improvement target river showed that most of the target river has a high discharge capacity in the water system for living and livestock. Analysis for the density of the total discharge capacity of the whole watershed of Chungcheongnamdo indicated that the river that needs water quality improvement has high BOD concentration and high discharge load density at the point that this river is located. Thus, for efficient watershed management through selection and concentration, Chungcheongnamdo needs to improve the target river in priority. Stepwise planning is also required to establish and execute the water quality improvement in order to satisfy said target water quality, and establish the index for the water improvement rate for its evaluation.

Crown Fuel Characteristics and Fuel Load Estimation of Pinus densiflora S. et Z. in Bonghwa, Gyeongbuk (경북 봉화 지역 소나무림에 대한 수관연료 특성과 연료량 추정)

  • Jang, Mina;Lee, Byungdoo;Seo, Yeonok;Kim, Sungyong;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The objectives of this study were to analyze the crown vertical structure, crown bulk density, and to develop regression models for predicting crown fuel load using the data from 10 destructively sampled Pinus densiflora trees in Bonghwa, Gyeongbuk. The fuel loads were observed higher in the middle portion of the vertical distribution of crown followed by the lower portion and upper portion of Pinus densiflora, respectively. Approximately 25% crown fuel load was found in the needle while 33% was observed in the branches with <1 cm diameter with a total of 58% available fuel loads. The average crown bulk density was $0.45kg/m^3$, and $0.27kg/m^3$ of this was available in the needles and branches with <1 cm diameters. The resulting models in linear equations were able to account for 84% and 88% of the observed variation, while the allometric equations with diameter at breast height as the single predictor showed better results to account for 90% and 95% of the observed variation in the available crown fuel loads and total crown fuel loads, respectively. The suggested equations in this study could provide quantitative fuel load attributes for crown fire behavior models and fire management of red pine stands in Bonghwa areas.

A study on the heat transfer characteristics during outward melting process of ice in a vertical cylinder (수직원통형 빙축열조내 외향용융과정시 열전달특성에 관한 연구 -작동유체의 유동방향 및 축열조 형상비에 따른 열성능 비교-)

  • Kim, D.H.;Kim, D.C.;Kim, I.G.;Kim, Y.K.;Yim, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.171-179
    • /
    • 1997
  • During the day time in summer, peak of air conditing load, and electric power management system lies under overloaded condition. The reason is the enlarged peak load value of electric power caused by increased air-cooling load in summer. To prevent load concentration during day time and overloaded condition of power management system, some energy storage methods are suggested. One of these methods is ice storage system. Water has some good properties as P.C.M.(Phase Chang Material) : Its melting point is the range of required operation temperature. It has large specific latent heat and is chemically stable compared to other organic or inorganic substances. It is cheap and easy to treat. This study represents experimental results of heat transfer characteristics of P.C.M. under the outward melting process in a vertical cylinder. We experimented with twelve combinations of conditions, i.e., three different inlet temperatures($7^{\circ}C,\;4^{\circ}C\;and\;1^{\circ}C$), two working fluid directions(upward and downward), and two aspect ratios, H/R(4 and 2). At the inlet temperature of $7^{\circ}C$ and $4^{\circ}C$, there was temperature stagnation region where the temperature of P.C.M. remains constant at $4^{\circ}C$ regardless of aspect ratio and direction of working fluid. This temperature stagnation occurs as the water, at its maximum density, flows down to the lower region. The phase change interface formed bell-shaped curve as the melting process continued. With a new set of conditions(4H/R, inlet temperature $4^{\circ}C$ and $1^{\circ}C$, downward/upwerd inlet direction), the movement of phase change interface was faster when the working flued inlet direction was downward. With the same set of conditions, melting rate and total melting energy were larger when the working fluid inlet direction was downward. The results were reversed when the other sets of conditions were applied.

  • PDF

A Study on Hand Hygiene Practices: A Comparison of Food Handlers with General Population (일반인과 식품취급자의 손 위생관리에 관한 비교)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.241-250
    • /
    • 2012
  • Objectives: This study was performed to investigate hygienic behavior of food handlers and general population focusing on awareness of hand-washing and the microbial load of their hands. Methods: A questionnaire survey and microbiological analysis were carried out for sixty-four people each. Samples for microbiological analysis were collected through the glove-juice method from the hands, and were analyzed for the presence of aerobic plate counts, total coliform, fecal coliform, Escherichia coli, Staphylococcus aureus, and Salmonella spp. according to the Food Code of Korea. Results: In the survey, significant differences between the food handlers and general population (p < 0.01) were found in hand-washing frequency, duration, use of hand-washing agents, washing parts of hands, hand-drying method, and method of turning off water. In eight different situations among the ten particular situations in their daily life, more food handlers responded to wash their hands than general population (p < 0.05). Bacterial load on hands with general population was consistently higher than with food handlers (p < 0.05), however, percentages of positive hands of S. aureus and Salmonella spp. were not. Conclusions: Poor hand hygiene practices were indicated by the positive results for E. coli, S. aureus, and Salmonella spp. on the hands of some respondents in both groups. This study reveals that there is the need for programs or campaigns to increase hand-washing practices of both groups.