• Title/Summary/Keyword: total load management

Search Result 415, Processing Time 0.026 seconds

INTERACTIVE MACHINE LIADUNG AND TOOL ASSIGNMENT APPROAH IN FLEXIBLE MANUFACTURING SYSTEMS

  • Kato, Kiyoshi;Oba, Fuminori;Hashimoto, Fumio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1576-1579
    • /
    • 1991
  • This paper discusses on the machine loading and tool allocation (MLTA) problem. Mathematical formulation of the problem is given first. Then a heuristic approach based on Group Technology (GT) is presented to deal with the MLTA problem effectively. By using this approach, part-tool group generation and their assignment to adequate machines can easily be obtained in consideration of the work load on each machine, the number of tool-set replacement, and the total number of cutting tools required through the interactive setting of the desired machine utilization rate.

  • PDF

Scheduling for Chartered Bus Service (전세버스일정계획)

  • ;;Katta G. Murty
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.10a
    • /
    • pp.149-152
    • /
    • 2000
  • The chartered bus scheduling is to determine the allocation of buses to customer service requests. For the scheduling, we first represent the scheduling problem using a graph and develop a mathematical model. Second, we develop an algorithm for the scheduling problem including heuristic methods. We tested the performance of the algorithm on instances with real data. As a result, the total empty load driving time is reduced over 10% comparing with that of current practice at the company

  • PDF

A Processor Assignment Problem for ATM Switch Configuration

  • Han, Junghee;Lee, YoungHo
    • Management Science and Financial Engineering
    • /
    • v.10 no.2
    • /
    • pp.89-102
    • /
    • 2004
  • In this paper, we deal with a processor assignment problem that minimizes the total traffic load of an ATM switch controller by optimally assigning processors to ATM interface units. We develop an integer programming (IP) model for the problem, and devise an effective tabu search heuristic. Computational results reveal the efficacy of the proposed tabu search procedure, finding a good quality solution within 5% of optimality gap.

Policy Directions of Total Maximum Daily Loads for the Scientific Management of Water Quality (과학적인 수질관리를 위한 오염총량관리제도의 추진 방안)

  • Park, Seok-Soon;Na, Yu-Mee;Na, Eun-Hye
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.2
    • /
    • pp.157-165
    • /
    • 2001
  • This paper presents the policy directions of total maximum daily loads(TMDL), which was recently adopted in Korea, for scientific management of water quality. The basic principles of water quality management are also discussed in this paper, along with the TMDL policy in United States as well as the previous policy in Korea. We discussed several unreasonable points out of the previous approaches, such as regulation of all point sources with equal standards, negligence of an assimilative capacity of the receiving water, and emphasis only on drinking water supply, etc.. For successful applications of the TMDL policy in Korea, the following directions are suggested: 1) the unit drainage basin for each TMDL application should be given, 2) the water body where the water quality standards should be maintained, needs to be guided, 3) the water quality parameters of TMDL should be given, 4) the technical guidances should be given for applications of water quality models, and 5) the seasonal TMDL would be allowed. In order to maximize the benefits of the TMDL policy, the local governments would need to implement the following strategies: 1) the increment of an assimilative capacity of the receiving water, 2) the effective controls of the non-point source pollution, 3) the advanced treatment of the point sources, 4) application of system optimization techniques along with effluent trade, and 5) utilization of watershed management systems.

  • PDF

Analysis of Characteristics of NPS Runoff and Pollution Contribution Rate in Songya-stream Watershed (송야천 유역의 비점오염물질 유출 특성 및 오염기여율 분석)

  • Kang Taeseong;Yu Nayeong;Shin Minhwan;Lim Kyoungjae;Park Minji;Park Baekyung;Kim Jonggun
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.316-328
    • /
    • 2023
  • In this study, the characteristics of nonpoint pollutant outflow and contribution rate of pollution in Songya-stream mainstream and tributaries were analyzed. Further, water pollution management and improvement measures for pollution-oriented rivers were proposed. An on-site investigation was conducted to determine the inflow of major pollutants into the basin, and it was found that pollutants generated from agricultural land and livestock facilities flowed into the river, resulting in a high concentration of turbid water. Based on the analysis results of the pollution load data calculated through actual measurement monitoring (flow and water quality) and the occurrence and emission load data calculated using the national pollution source survey data, the S3 and S6 were selected as the concerned pollution tributaries in the Songya-stream basin. Results of cluster analysis using Pearson correlation coefficient evaluation and Density based spatial clustering of applications with noise (DBSCAN) technique showed that the S3 and S6 were most consistent with the C2 cluster (a cluster of Songya-stream mainstream owned area) corresponding to the mainstream of Songya-stream. The analysis results of the major pollutants in the concerned pollution tributaries showed that livestock and land pollutants were the major pollutants. Consequently, optimal management techniques such as fertilizer management, water gate management in paddy, vegetated filter strip and livestock manure public treatment were proposed to reduce livestock and land pollutants.

Distributed Energy System Connection Limit Capacity Increase Technology Using System Flexible Resources (계통유연자원을 활용한 분산에너지 계통접속 한계용량 증대 기술)

  • Jeong Min Park
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.139-145
    • /
    • 2023
  • Due to changes in the distribution system and increased demand for renewable energy, interest in technology to increase the limit capacity of distributed energy grid connection using grid flexible resources is also increasing. Recently, the distribution system system is changing due to the increase in distributed power from renewable energy, and as a result, problems with the limited capacity of the distribution system, such as waiting for renewable energy to connect and increased overload, are occurring. According to the power generation facility status report provided by the Korea Power Exchange, of the total power generation capacity of 134,020 MW as of 2021, power generation capacity through new and renewable energy facilities is 24,855 MW, accounting for approximately 19%, and among them, power generation through solar power accounts for a total portion of the total. It was analyzed that the proportion of solar power generation facilities was high, accounting for 75%. In the future, the proportion of new and renewable energy power generation facilities is expected to increase, and accordingly, an efficient operation plan for the distribution system is needed. Advanced country-type NWAs that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power in order to improve distribution network use efficiency without expanding distribution facilities due to the expansion of renewable energy. An integrated operating system is needed. In this study, in order to improve the efficiency of distribution network use without expanding distribution facilities due to the expansion of renewable energy, we developed a method that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power. We want to develop an integrated operation system for NWAs similar to that of advanced countries.

QL2-XP Model for the Automatic Calibration in Water Quality Modeling (하천 수질 매개변수의 자동보정을 위한 QL2-XP 모형 개발)

  • Han, Kun-Yeun;Park, Kyung-Ok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.474-477
    • /
    • 2005
  • The Industrial development and the Increase in population have brought out a rapid increase of wastewater discharge. To deal with this matter, much estimate has been spend on construction and management of a large scale sewage treatment plant. Although every effort has been carried out, river water quality has no significantly improved. Especially. the aggravation of the water quality in dry season is brought out a serious social problem. The purpose of this study Is the development of an optimal water quality management technique considering the efficient control of the multiple pollutant load associated with the total pollutant load control. A GUI(Graphical User Interface) system named 'QL2-XP' model is developed by object-oriencted language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis. water quality analysis, optimized model calibration processes, and postprocessing the simulation results.

  • PDF

Comparison of Characteristics of Suspended Matters in Streams by Dry/Rainy season and Watershed Characteristics (비강우/강우기와 유역특성에 따른 하천의 부유물질 성상별 유출 특성 비교)

  • Park, Jihyoung;Sohn, Sumin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.739-745
    • /
    • 2013
  • This paper investigated the runoff characteristics of different properties of suspended solids in streams according to the watershed characteristics and dry/rainy season. Suspended solids were divided into VSS and NVSS depending on volatilization. The main results of this study were as follows. TSS were more correlated with NVSS than VSS. Suspended solids were positively related with the proportion of urban > paddy > upland, negatively related with forest cover. VSS were positively correlated with POP and POC. VSS, measured in dry season, would partly result from autochthonous production and could be an indirect indicator of organic suspended solids.

Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake (팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정)

  • Kim, Dong Woo;Jang, Mi Jeong;Han, Ihn Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-377
    • /
    • 2014
  • Paldang lake which is the most important water resource in Korea is classified as a stream type reservoir and water quality of Paldang lake can be significantly influenced by external pollutant source. So this study was aimed to determine focused control BOD and TP sources of each unit watershed upper Paldang lake through analysis of pollutant source distribution and pollutant runoff characteristics. Generated load, discharge load, delivery load and each load density of 11 unit watersheds upper Paldang lake were calculated using data of water quality and flow rate from pollutant sources and 74 small streams. As a result of generated load, discharge load and delivery load of BOD and TP from pollutant sources, the most BOD generated load was taken by livestock with 66% of total BOD discharge load and domestic had the most BOD discharge load, 42.7%. The ratio of delivery load of livestock and domestic was 36.4% and 34.3%, respectively. Livestock occupied high ratio of TP generated load, discharge load and delivery load with 82.5%, 44.4% and 46.7%, respectively. Gyeongan watershed which had high population density showed the highest BOD delivery load density of $14.6kg/km^2/d$ and the highest TP delivery load density with $1.23kg/km^2/d$ was analyzed in Cheongmi watershed including the biggest number of livestock. From these results, management of domestic sewer and livestock excrement was determined as a focused control pollutant source. And intensive management about domestic sewer in Gyeongan stream and livestock excrement in Cheongmi stream is required for water quality improvement of Paldang lake.

Estimation of Delivery Ratio Based on BASINS/HSPF Model for Total Maximum Daily Load (BASINS/HSPF 모형을 이용한 수질오염총량관리 유달율 산정방법 연구)

  • Park, Ju-Hyun;Hwang, Hasun;Rhew, Doughee;Kwon, Oh-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.833-842
    • /
    • 2012
  • In this study Window interface to Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Namgang watershed to estimate its applicability for estimating Delivery Ratio (DR) of water pollutants for Total Maximum Daily Load (TMDL). BASINS/HSPF which is selected in this study, is found to be appropriate for simulation of daily flow and water quality in target basins. DR was estimated utilizing discharge loads of unobserved sub-basin and delivery load of unobserved locations obtained not by actual evaluation but by simulation through validation and verification. Annual average DR of BOD, TN and TP were 0.97 ~ 1.50, 2.23 ~ 3.21, and 0.81 ~ 1.09 respectively. Net DR of dependent basins excluding influence of upstream basin was 1.50 ~ 1.70, 0.55 ~ 0.69, and 0.24 ~ 0.31, all of which are lower than those of independent basins area. Utilizing the model selected by this research, DR and Net DR of unobserved basins will be estimated, which will help determine priorities in management of basin areas.