• Title/Summary/Keyword: total discharge

Search Result 1,219, Processing Time 0.036 seconds

The Prediction of Total Revenue of V2G System Considering Battery Wear Cost (배터리 열화비용을 고려한 V2G 시스템의 수익예측)

  • Won, Il-Kuen;Kim, Do-Yun;Ko, An-Yeol;Shin, Chang-Hyun;Hwang, Jun-Ha;Kim, Young-Real;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.85-94
    • /
    • 2015
  • Recently, research on the smart grid that combines ICT(Information & Communication technology) to the power system has been actively progressed. If the occupancy of the EV(Electric vehicle) is increased. the V2G(Vehicle to grid) system is available which constitutes the micro-grid through battery of EV. V2G system performs load leveling and efficient energy consumption by battery operation considering load condition. But, if the battery is used only depending on the electricity rates, it doses not consider the life of the battery. The ACC(Achievable cycle) and the total transferable energy of battery varies corresponding to the selected DOD(Depth of discharge). In this paper, the optimal DOD selection method of V2G system considering battery wear cost and average driving distance of EV. Also, the total revenue prediction of various nation is presented considering the actual electricity costs per hour.

Characteristics of Concentration of Pollutants from a Rural Watersheds during Dry Days (평상시 농촌유역에서의 오염물질의 농도특성)

  • Oh, Kwang-Young;Kim, Jin-Soo;Khan, Jong-Bum;Cho, Jae-Won
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.639-642
    • /
    • 2003
  • Characteristics of concentration of pollutants such as total nitrogen(T-N), total phosphorus(T-P) and chemical oxygen demand(COD) during dry days of $2002{\sim}2003$ were investigated for streamwater from a rural watershed. Water was sampled and discharge was measured at 5-days intervals at outlet of study area. The mean concentrations of pollutants in non-irrigation and irrigation period not significantly different. For increasing discharge in 2002, TN concentration increased but COD concentrations decreases.

  • PDF

A Study on Light Guide Luminaire Design using Prismatic Film (프리즘 필름을 이용한 조명기구 설계 연구)

  • Jeong, Hak-Geun;Han, Su-Bin;Jung, Bong-Man;Lee, Euy-Jun
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • There are a number of practical uses for devices which are capable of piping large amounts of light: illumination of areas where there would be maintenance, safety, or security problems with electronic light sources; piping sunlight into indoor areas for illumination; and the conversion of high luminous efficacy, good color quality, high intensity discharge lamps into more acceptable linear of area sources of light. Prism light guides are hollow structures which pipe light by means of total internal reflectin(TIR). These devices are unique in their ability to combine the efficiency of TIR with the relatively low cost of hollow structure. An important application stems from their ability to transform a point source of light such as an incandescent or discharge lamp into a linear or area source of light or illumination. We report the development of an economical, flexible prismatic film for fabricating the light guide wall. This guide geometries and films are currently under development.

Characteristics of Concentration of Pollutants from a Rural Watersheds during Dry Days (평상시 농촌유역에서의 오염물질의 농도특성)

  • Oh, Kwang Young;Kim, Jin Soo;Khan, jong bum;Cho, Jae Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.395-398
    • /
    • 2004
  • Characteristics of concentration of pollutants such as total nitrogen(T-N), total phosphorus(T-P) and chemical oxygen demand(COD) during dry days of $2002\~2003$ were investigated for streamwater from a rural watershed. Water was sampled and discharge was measured at 5-days intervals at outlet of study area. The mean concentrations of pollutants in non-irrigation and irrigation period not significantly different. For increasing discharge in 2002, TN concentration increased but COD concentrations decreases.

  • PDF

Energy and Exergy Analysis of Maeeum-Ri Geothermal District Heating System (지열을 이용한 매음리 지역난방에 관한 에너지 및 엑서지 분석)

  • Kim, Jin-Sang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.2
    • /
    • pp.13-19
    • /
    • 2009
  • This study describes energy and exergy analysis of the Maeeum-Ri Geothermal District Heating System(MGDHS) of Ganghwa Island, Incheon, Korea. Design data are used to assess the performance of the geothermal district heating system. Geothermal resources of MGDHS are found to be low quality with specific exergy index of 0.029. Exergy losses occur in the pumps and heat exchangers as well as in the geothermal Quid and direct discharge. As a result, the total exergy losses accounts for 5.2% in pumps, 47% in the discharge, and 3.3% in heat exchanger based on the total exergy input to the entire MGDHS. The overall energy and exergy efficiencies of the system are found to be 28.8% and 44.5%, respectively.

  • PDF

Mass Balance of Pollutants at a Paddy Field Area During Irrigation Period (관개기 광역논에서의 오염물질의 수지(지역환경 \circled3))

  • 오승영;김진수;김규성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.617-622
    • /
    • 2000
  • Concentration of pollutants and discharge were monitored regularly at paddy field area during irrigation periods. The amounts of irrigation water during irrigation water during irrigation periods in 1999 were 3690mm. The concentration of pollutants in ponded water are high during fertilizer application period. The ratio of discharge of direct runoff Q$\_$D/ to the total runoff is 9%. The ratios of the load of direct runoff L$\_$D/ to the total load L$\_$T/ are 6% for T-N, 16% for T-P and 16% for COD. It was found that the ratios of the concentration are 0.7 for T-N, 1.8 for T-P and 1.9 for COD. The unit load of T-N, T-P and COD during irrigation periods were 12.1kg/㏊, 0.42kg/㏊ and 85.7kg/㏊, respectively

  • PDF

Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas (장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정)

  • Joo, Jingul;Yoo, Doguen;Kim, Joonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.841-847
    • /
    • 2011
  • In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.

Assessment of Relationship between Sediment-Discharge Based on Rainfall Characteristic using SWAT Model (SWAT 모델을 이용한 강우특성 변화에 의한 퇴적물-유출량 간의 관계 평가)

  • Kim, Jisu;Kim, Minseok;Cho, Youngchan
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.118-129
    • /
    • 2021
  • The sediment transportation caused by soil erosion due to rainfall-discharge in the large watershed scale plays critical role in human society. The relationship between rainfall-discharge-sediment transportation is depending on the start time of rainfall and end of rainfall but, the studies related with rainfall characteristics are insufficient. In this study, The Soil and Water Assession Tool (SWAT) model was used to study the relationship between rainfall-discharge-sediment transportation at the Sook river watershed which is monitored by the Ministry of Environment. To do this, first of all, the sensitivity analysis about model attributes was performed using monitored data. The accuracy analysis of SWAT model was conducted using the model's efficiency index (Nash and Sutcliffe model efficiency; NSE) and the coefficient of determination (R2). After that, it was studied what results could be obtained according to changes in rainfall timing and end points. In the result of discharge simulation, the modified rainfall values (sum of total rainfall starting time and end time) showed more high accuracy values (R2:0.90, NSE: 0.8) than original rainfall values (R2:0.76, NSE: 0.72). In the result of sediment transportation simulation, during calibration had more resonable results(R2:0.87, NSE: 0.86) than compared with original rainfall values (R2:0.44, NSE: 0.41). However, validation results of sediment transportation simulation showed low accuracy values compared with calibration results. This results maybe cause monitoring periods of sediment flow compared with discharge monitoring periods. Nevertheless, since rainfall characteristic plays critical rule in model results, continuous research on rainfall characteristic is needed.

A Method of Rating Curve Adjustment (수위유량곡선보정방법에 대하여)

  • 박정근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.2
    • /
    • pp.4116-4120
    • /
    • 1976
  • With the use of many rivers increased nearly to the capacity, the need for information concerning daily quantities of water and the total annual or seasonal runoff has became increased. A systematic record of the flow of a river is commonly made in terms of the mean daily discharge Since. a single observation of stage is converted into discharge by means of rating curve, it is essential that the stage discharge relations shall be accurately established. All rating curves have the looping effect due chiefly to channel storage and variation in surface slope. Loop rating curves are most characteristic on streams with somewhat flatter gradients and more constricted channels. The great majority of gauge readings are taken by unskilled observers once a day without any indication of whether the stage is rising or falling. Therefore, normal rating curves shall show one discharge for one gauge height, regardless of falling or rising stage. The above reasons call for the correction of the discharge measurements taken on either side of flood waves to the theoretical steady-state condition. The correction of the discharge measurement is to consider channel storage and variation in surface slope. (1) Channel storage As the surface elevation of a river rises, water is temporarily stored in the river channel. There fore, the actual discharge at the control section can be attained by substracting the rate of change of storage from the measured discharge. (2) Variation in surface slope From the Manning equation, the steady state discharge Q in a channel of given roughness and cross-section, is given as {{{{Q PROPTO SQRT { 1} }}}} When the slope is not equal, the actual discharge will be {{{{ { Q}_{r CDOT f } PROPTO SQRT { 1 +- TRIANGLE I} CDOT TRIANGLE I }}}} may be expressed in the form of {{{{ TRIANGLE I= { dh/dt} over {c } }}}} and the celerity is approximately equal to 1.3 times the mean watrr velocity. Therefore, The steady-state discharge can be estimated from the following equation. {{{{Q= { { Q}_{r CDOT f } } over { SQRT { (1 +- { A CDOT dh/dt} over {1.3 { Q}_{r CDOT f }I } )} } }}}} If a sufficient number of observations are available, an alternative procedure can be applied. A rating curve may be drawn as a median line through the uncorrected values. The values of {{{{ { 1} over {cI } }}}} can be yielded from the measured quantities of Qr$.$f and dh/dt by use of Eq. (7) and (8). From the 1/cI v. stage relationship, new vlues of 1/cI are obtained and inserted in Eq. (7) and (8) to yield the steady-state discharge Q. The new values of Q are then plotted against stage as the corrected steadystate curve.

  • PDF

Variations of Calcium, Bicarbonate, and Cation in the Lacustrine Zone by Interannual Differences in Up-River Discharge

  • An, Kwang-Guk;Lee, Jae-Hoon;Han, Jeong-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.4
    • /
    • pp.471-476
    • /
    • 2010
  • Monthly up-river discharge in the riverine zone analysis resulted in large interannual variations and differences in calcium ($Ca^{2+}$), bicarbonate ($HCO_3^-$), and cations in the lacustrine zone (Lz) of Daecheong Reservoir during the wet year (Wy, 1993) vs. dry year (Dy, 1994). Total up-river discharge in the Wy was four times that of the Dy, and the up-river discharge in July~August of the Wy was eight times greater than that of same period of Dy. Annual water retention time in the Lz showed large difference between the two years. Water residence time (WRT) was minimum when the up-river discharge peaked, whereas the WRT was maximum when the up-river discharge was at minimal condition. This peak discharge from the up-river on early July reduced residence time in the Lz on mid-July~late July. Monthly pattern, based on data of May~November, was similar between the two years, but, but mean retention time in the Wy was 50 days shorter than in the Dy. Such hydrology, up-river discharge, and WRT reduced $Ca^{2+}$, $HCO_3^-$, and cations in the Lz. At low up-river discharge in Wy during April~May, the cation content of Ca+Mg+Na+K averaged 1.17meq $L^{-1}$ (range=1.09-1.26meq $L^{-1}$), but as the up-river discharge increased suddenly, the values decreased. Seasonal fluctuations of $Ca^{2+}$ showed exactly same pattern with bicarbonate ion of $HCO_3^-$. The minimum $Ca^{2+}$ (0.03meq $L^{-1}$) was occurred in the early August of wet year and coincided with the minimum $HCO_3^-$. These results suggest that the magnitude of variation in $Ca^{2+}$, bicarbonate, and cations in the lacustrine zone is directly determined by the peak magnitude of up-river discharge. The magnitude of up-river discharge determined water retention time and the magnitude of ionic dilution in the lacustrine zone, resulting in functional changes of the ecosystem.