Journal of the Korean Society for Geothermal and Hydrothermal Energy (한국지열·수열에너지학회논문집)
- Volume 5 Issue 2
- /
- Pages.13-19
- /
- 2009
- /
- 2799-4783(pISSN)
- /
- 2799-4805(eISSN)
Energy and Exergy Analysis of Maeeum-Ri Geothermal District Heating System
지열을 이용한 매음리 지역난방에 관한 에너지 및 엑서지 분석
- Kim, Jin-Sang (Korea Technical Center for Geothermal Energy)
- 김진상 (한국지열에너지기술지원센터)
- Published : 2009.12.01
Abstract
This study describes energy and exergy analysis of the Maeeum-Ri Geothermal District Heating System(MGDHS) of Ganghwa Island, Incheon, Korea. Design data are used to assess the performance of the geothermal district heating system. Geothermal resources of MGDHS are found to be low quality with specific exergy index of 0.029. Exergy losses occur in the pumps and heat exchangers as well as in the geothermal Quid and direct discharge. As a result, the total exergy losses accounts for 5.2% in pumps, 47% in the discharge, and 3.3% in heat exchanger based on the total exergy input to the entire MGDHS. The overall energy and exergy efficiencies of the system are found to be 28.8% and 44.5%, respectively.
Keywords