• 제목/요약/키워드: total discharge

검색결과 1,198건 처리시간 0.022초

심장병 관리 개별교육이 관상동맥질환자의 자가간호수행과 혈중 콜레스테롤에 미치는 효과 (Effects of Individualized Cardiac Health Education on Self Care Behavior and Serum Cholesterol in Patients with Coronary Artery Disease)

  • 조혜영;김희승
    • 성인간호학회지
    • /
    • 제22권3호
    • /
    • pp.322-328
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of an individualized cardiac health education on self-care behavior and serum cholesterol levels patients with coronary artery disease. Methods: Twenty-two patients in the intervention group and 22 in the control group were assigned randomly in this study. The intervention group received an individualized cardiac health education program which consisted of four different sessions for a total of four sessions. Specifically, two sessions occurred during the patients' hospitalization with a third session at the time of discharge with a fourth session scheduled via telephone one week post discharge. Data were collected through a questionnaire for self-care behavior and a blood test for total cholesterol at the time of admission and the two weeks after discharge. The questionnaire for self-care behavior was a standardized instrument and serum cholesterol was measured by Accutrend GC (Roche, Germany). Results: Self-care behavior scores included diet, medication, exercise, risk factor, blood pressure measurement, and visits to hospital were significantly more in the experimental group compared to the control group. Conclusion: The above findings indicate that the individualized cardiac health education was effective in increasing of self-care behavior.

總流砂量의 算定을 위한 流砂濃度式의 導出 (Derivation of Sediment Concentration for the Computation of Total Sediment Discharge)

  • 이종석;김진규;차영기
    • 물과 미래
    • /
    • 제29권1호
    • /
    • pp.181-190
    • /
    • 1996
  • 충적수로에서 유사량의 정량적인 산정은 초기운동개념이나 유사이송개념에 의한 방법에 기초하여 구하고 있다. 본는 연구에서는 유사이송개념에 의한 결정방법중의 하나인 회귀분석법에 의해 총유사량을 산정할 수 있는 유사농도에 관한 관계식을 유도하였다. 관계식의 유도에는 135개의 현장자료와 225개의 실험자료가 포함된 360개의 실측자료가 이용되었다. 또한 다중회귀분석법에 의한 관계식은 수심, 평균유속, 수로경사, Froude 수 및 하상재료의 중앙입경을 독립변수로 하여 유도되었다.

  • PDF

Film-Cooling Hole의 유출계수에 관한 수치해석적 연구 (A Computational Study for the Discharge Coefficient of a Film-Cooling Hole)

  • 김재형;김희동;박경암
    • 한국추진공학회지
    • /
    • 제7권2호
    • /
    • pp.15-22
    • /
    • 2003
  • 본 연구에서는 2차원 압축성 Navier-Stokes 방정식을 사용하여 $30^{\cire}$ 경사진 터빈익의 냉각구를 통한 유출계수를 예측하였다. 내/외부 유동이 유출계수에 미치는 영향을 알아보기 위하여 외부유동만 존재하는 경우, 내부유동만 존재하는 경우 그리고 내/외부 유동이 없는 3가지 경우에 대하여 수치해석을 수행하였으며. 실험결과와 비교하였다. 본 연구의 수치해석결과는 유출계수를 잘 예측하였으며, 외부유동은 유출계수를 감소시키고, 내부유동은 냉각구내에서의 전압손실과 경계층의 영향을 감소시켜 특정 구간에서 유출계수를 증가시킨다는 것을 알았다.

도시화 유역에서의 홍수 유출 특성 (Flood Runoff Characteristics in Urbanized Basin)

  • 한국희;이길춘
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.153-161
    • /
    • 1996
  • 최근에 도시화 된 산본천 유역을 대상으로 한 유출 해석이다. 실측한 각종 자료를 유출해석 모형인 ILLUDAS를 이용하여 도시화에 따른 첨두유량과 총유출량의 연구를 분석하였다. 도시하천에서 첨두유량의 증가는 도시화에 따른 하정비가 가장 큰 영향이 있는 것으로 판단된다. 첨두유량은 강우 지속시간이나 재현기간에 따라 조도계수 n=0,04일 경우에 최대 10%까지, n=0.015일 경우는 7~16%이었으며, 또한 자연하도(n=0.04)에서 계획하도(n=0.015)로 변화하면 첨두유량은 51~158%까지 큰 폭의 증가를 보였다. 일반적으로 호우시 홍수첨두유량은 증가하지만 도시유역의 경우는 배수계통의 정비로 유속이 증가하면서 하천 수위는 오히려 감소하는 것으로 나타났다.

  • PDF

Effect of The Impeller Discharge Angle on the Performance of a Spurt Vacuum Pump

  • Lee, Ji-Gu;Kim, Youn-Jea
    • Applied Science and Convergence Technology
    • /
    • 제26권1호
    • /
    • pp.1-5
    • /
    • 2017
  • The spurt vacuum pump is widely used to transfer sludge and slurry, and to control flow rate in a variety of processing fields, such as the oil, chemical, and fiber industries. The efficiency of the pump depends on the design parameters of the impeller, such as the number of blades, and the blade angle. In this study, the effect of the configuration of the impeller discharge angle of a spurt vacuum pump, which influences total head, shaft power, and efficiency, was numerically investigated using the commercial code, ANSYS CFX ver. 16.1. In addition, the performance of the pump was evaluated on the basis of the correlations between the total head, pump efficiency, and pressure distribution.

병원관리에서 의료보험 입원진료비의 병원자체심사 결과의 분석 연구 - 일 대학병원의 퇴원전 심사를 중심으로 (Analytic Study of the Hospital Self Inspection Results with the Medical Insurance Inpatient Fee on the View-point of the Hospital Management. -based on the University hospital Pre-discharge inspection-)

  • 문선순
    • 대한간호
    • /
    • 제32권5호
    • /
    • pp.78-92
    • /
    • 1994
  • The purposes of this study were to evaluate the results of the hospital self inspection with the medical insurance and to offer basic materials to the medical insurance inspection and the education of medical insurance. The study was undertaken with 4,730 cases among the total 13,810 medical insurance in patients from Jan. 1990 to Dec. 1990 at one university hospital in Pusan. The major contents of the inspection were the omission of diagnosis and medical fee, curtailment, application mistake, the rates of inclusion, subtraction and total accumulation. The data were collected using patients charts and bills. The results of the paper analysis were as follows. 1. From the pre-discharge hospital self inspection, major omission were treatment and material fee but medication fee were moderately high and high curtailment was operation fee. 2. Decreasing order of operation fee adjustment were digestive(22.4%) muscular(22%) and neuro system operation(21.4%). Majority of the medication fee adjustments were injection form of medication(95.7%). 50% of the treatment fee adjustments were composed of injection fee(27.9%) and dressing or post-operative dressing fee(22.3%). 74.7% of material costs were composed of oxygen(30.6%), blood and the blood composed materials(44.1%). 3. Pre-discharge inspection showed 6% adjustment rate, 4.3% addition and 2.1% curtailment rate. Most of the adjustment were omission(66.1%). 4. Omission were divided by event omission(92.6%)and application mistake(7.4%). The decreasing order of omission fee were operation(21.84%), treatment(18.71 %) diagnosis(18.68%), medication (14.53%) and material costs(10.84%). So operation and treatment part were the major part of the total omission fee(40.55%). 5. The average omission of diagnosis were 1,800 per month.

  • PDF

농어촌지역 미활용에너지의 부존량과 이용 가능량 분석 (A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community)

  • 박미란;류연수;김진욱;이용욱;배성돈;채갑병
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.

소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond)

  • 박이동;서지원
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

HDIV를 위한 PDP의 표시방전특성에 관한 연구 (A Study on the Display Discharge Characteristics of PDP for the HDTV)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.39-46
    • /
    • 2005
  • 본 연구는 3 전극 교류구동형 PDP의 ADS구동방식에 관한 것으로 휘도의 저감이 없는 안정적인 표시방전이 가능한 최소의 어드레스와 표시방전 유지펄스의 폭을 도출하는 것이다. 실험결과로부터 어드레스 펄스폭이 $1.5[{\mu}s]$이 상만 되면 효과적인 어드레스 방전이 가능하였고 35[V] 어드레스 동작마진을 얻을 수 있었다. 또한, 표시방전 유지펄스의 폭이 $2[{\mu}s]$이상 되면 25[V]의 동작마진을 가지고 안정적인 표시방전의 유지가 가능하였다. 이 조건들을 수평 주사선수 1080라인의 Full-HDTV급 PDP에 적용할 경우 8개의 서브필드와 총 1420개의 표시방전 유지펄스를 사용할 수 있다.

원격감시 기능을 갖는 고감도 부분방전센서 (Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities)

  • 최규남
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.349-356
    • /
    • 2015
  • 광학적 잡음과 전기적 잡음을 복합적으로 제거할 수 있는 하이브리드 필터를 채용하고 펄스형태의 아크 광 신호를 적분하여 수신되는 아크에너지의 크기로 감지할 수 있는 원격감시 기능을 갖는 고감도 부분방전 센서를 구현하였다. 하이브리드 필터는 부분방전 센서가 설치되는 배전반 내 환경에서 내부 형광등과 백열등 조명에 대하여 영향을 받지 않음을 보여주었다. 종래에는 아크광의 불규칙한 파형특성으로 인하여 첨두치가 감지되어 아크광의 크기에 비례한 선택적 감지가 어려웠으나, 센서에 적용된 적분연산 기능은 각기 다른 아크광의 에너지 레벨에 대하여도 선택적으로 감지가 가능함을 실험적으로 보여주었다. 센서는 2m 이격된 원격지에서 100A 저압 MCCB의 정상 개폐 시 발생하는 섬광에 해당하는 광 에너지에 대해서도 감지가 가능함을 보여주어 원격감시 기능을 갖는 고감도 부분방전센서에 적용 가능함을 보여주었다.